Showing results: 616 - 630 of 1891 items found.
-
40-788-011 -
Pickering Interfaces Ltd.
The 40-788-011 (PXI) and 42-788-011 (PXIe) are single failsafe SP8T 8 GHz unterminated microwave multiplexers. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
40-882-004 -
Pickering Interfaces Ltd.
A 50 Ohm 4 to 1 6GHz PXI RF multiplexer available as a single MUX in one PXI slot, a dual MUX in two PXI slots, or triple and quad MUXs in three slot PXI modules. This PXI multiplexer exhibits low VSWR characteristically over the full operating frequency range and consistent insertion loss characteristics. The use of solid state switches ensures a long service life with no wear out mechanism, making the 40-882 MUX ideal for ATE systems requiring frequent and fast operating RF switching.
-
40-788-021-E -
Pickering Interfaces Ltd.
The 40-788-021-E (PXI) and 42-788-021-E (PXIe) are single failsafe SP8T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-021-E -
Pickering Interfaces Ltd.
The 40-788-021-E (PXI) and 42-788-021-E (PXIe) are single failsafe SP8T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-041-E -
Pickering Interfaces Ltd.
The 40-788-041-E (PXI) and 42-788-041-E (PXIe) are single failsafe SP8T 26.5 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-041-E -
Pickering Interfaces Ltd.
The 40-788-041-E (PXI) and 42-788-041-E (PXIe) are single failsafe SP8T 26.5 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
Pickering Interfaces Ltd.
The 40-788-121-E (PXI) and 42-788-121-E (PXIe) are single failsafe SP10T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-131-E -
Pickering Interfaces Ltd.
The 40-788-131-E (PXI) and 42-788-131-E (PXIe) are single failsafe SP10T 22 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-221-E -
Pickering Interfaces Ltd.
The 40-788-221-E (PXI) and 42-788-221-E (PXIe) are single failsafe SP12T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-221-E -
Pickering Interfaces Ltd.
The 40-788-221-E (PXI) and 42-788-221-E (PXIe) are single failsafe SP12T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-121-E -
Pickering Interfaces Ltd.
The 40-788-121-E (PXI) and 42-788-121-E (PXIe) are single failsafe SP10T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-121-E -
Pickering Interfaces Ltd.
The 40-788-121-E (PXI) and 42-788-121-E (PXIe) are single failsafe SP10T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-131-E -
Pickering Interfaces Ltd.
The 40-788-131-E (PXI) and 42-788-131-E (PXIe) are single failsafe SP10T 22 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-011-E -
Pickering Interfaces Ltd.
The 40-788-011-E (PXI) and 42-788-011-E (PXIe) are single failsafe SP8T 8 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-011-E -
Pickering Interfaces Ltd.
The 40-788-011-E (PXI) and 42-788-011-E (PXIe) are single failsafe SP8T 8 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.