  • IRIG-B TTL TO RS485 Converter

    SPC - INS - 1010 - Signals & Systems India Private Limited

    The IRIG-B TTL signal is a time synchronization protocol that can be transmitted up to 50m maximum using coaxial cable. So the relay which is to be received the IRIG-B TTL signal may be far away from the IRIG-B source. The relay may be not able to synchronize with the GPS. To avoid such an incident in the field, some of the relays have provision to receive IRIG-B RS485 signal. The IRIG-B RS485 signal can able travel up to 1200m without any booster. All Time source equipment may not be supplied with IRIG-B RS485 signal output. The converter will act as a bridge between GPS Time source and Relays for time synchronization.

  • PXI 10A Fault Insertion Switch 6-chan 2-bus

    40-192-012 - Pickering Interfaces Ltd.

    This PXI fault insertion switch uses solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test: Open-Circuit. Short-Circuit between UUT connections. Short-Circuit to external signals. Through relays on each channel enable signals to the UUT to be set open-circuit. Fault Insertion Buses allow any channel to be shorted to any other channel and also enable any channel to be connected to an external signal such as Power, Ignition or Ground to simulate fault conditions. The module is supplied with 2 fault buses.

  • SHC68-C68-D4 Shielded Single-Ended Cable, 0.55 m

    781013-01 - NI

    68-Pin, Male VHDCI to 68-Pin, Male VHDCI, 50 Ω, 0.55m, Shielded Digital Cable - The SHC68-C68-D4 Digital Cable connects NI 6535/6/7, 654x, 655x, and 657x digital instruments with other NI accessories like the CB-2162 Connector Block or SMB-2163 Terminal Block. You can also use it with certain Digital I/O Adapter Modules for FlexRIO, Digitizer Adapter Modules for FlexRIO, Signal Generator Adapter Modules for FlexRIO, and high-speed serial instruments. It is flexible and easily fits around custom test fixtures and other equipment. It is a shielded, 50 Ω cable and is offered in different lengths.

  • SpaceWire-USB Brick Mk3

    326 - STAR-Dundee

    The SpaceWire Brick Mk3 is a USB 3.0 (also works with USB 2.0 and USB 1.1) to SpaceWire interface device that is suitable for use in all stages of SpaceWire equipment development: initial SpaceWire evaluation, instrument simulation, control system simulation, unit testing, integration support, and EGSE. The SpaceWire Brick Mk3 provides two SpaceWire interfaces, support for high speed data transfer, the capability to inject various types of errors on demand, the ability to transmit and receive time-codes and act as a time-code master, and comes complete with highly optimised host software for low latency transmission of SpaceWire packets directly to and from the host PC.

  • Temperature & Humidity Testing

    Environment Associates Inc.

    Environment Associates is outfitted with multiple chambers to suit all types of temperature and humidity testing needs, including: table-top, standard-reaching, fixed or portable walk-in chambers, and if needed, drive-in chambers. All Environment Associates test chambers are equipped with separate data-acquisition equipment for temperature and humidity monitoring. Our temperature and humidity chambers can be readily equipped with specialized data acquisition to digitally record chamber conditions and the test article at multiple data points. Many of our temperature and humidity chambers are equipped with high-performance, maximum-size compressors to produce superior ramp rates equal to or greater than 15°C per minute.

  • CPCI Or PXI PCM & ARINC 717 Board

    MS 1703 - Meltronics Systemtech

    *Bus Interface - PXI / CPCI Bus*Microprocessor and FPGA design based Board*One Channel ARINC 717 Transmitter and Receiver*Generates all PCM telemetry signals like NRZ, Bi-Phase, Differential Bi-phase, DM signals*Used to test all types of PCM based telemetry equipments*Configurable output signals format (parity, word length, Minor, Major frame, Bit position)*User can configure the words and there positions in the frame*The word can be either a square / triangle wave data or constant data*1 MB Shared Memory for Data Storage*Driver interface for Windows2000/XP/VISTA and LINUX OS

  • 100 Ampere Micro OHM Meters

    Neutronics Manufacturing Co.

    Introduction: Measuring the line loop contact resistance by bridges is not the ideal method as the test current is only a few milli amperes. Thus the value is not the true value of the contact resistance. Model HL- 100 is a direct reading tester,  and uses a test current of 100A DC,  resulting in true v alue and accur ate measurements. Model HL- 100 adopts digital circuit technique and is used for measuring contact resistance of switch control equipments at test current of 100A DC. The measurements are accurate as the test is highly stable.HL- 100 is a new,  fully automatic micro controlled tester that measures contact resistance at 100A DC with built in printer. The advantages of HL-100

  • Frequency Tripling Test Transformer

    SBF - Wuhan Sangao Electrical Test Installations Limit Co.

    Specificationstripping test transformer1.easy to operate, with stable features.2.Can meet the induced voltage withstand request ofTtripping est transfromer,frequency tripling transformer, frequency tripling generator, frequency power generatorproduct features1.Easy to operate, with stable features.2. Can meet the induced voltage withstand request of the transformer, mutual inductor.product parameters1. Output voltage: three phases 380V 50HZ2. Input voltage: single phase 0~300V/0~500V(continuously adjustable) frequency:150HZ3. Output capacity: 5KVA and above.Harmonic distortion:<5%-8%4. No-load running time:≤5minutes5.duration of the measured equipment under rated voltage: 40 seconds

  • RF Milliwatt Meters

    Type NDB-2 and NDB-3 - National RF, Inc

    National RF’s Type NDB-2 and NDB-3 RF Milliwatt Meters are affordable pieces of test equipment for both the RF laboratory and the home experimenter. Both provide a digital reading of RF power in dB reference 1 milliwatt of power into a 50 ohm load (i.e. 0 dBm). The circuitry consists of a low noise logarithmic amplifier that drives a digital A/D converting meter circuit. The lowest power levels that can be read are about –73 dBm (approximately 40 microvolts or .00000003 milliwatts). The maximum power input should not exceed 10 milliwatts (+10 dBm or .010 watts) when inputed without attenuation. An internal attenuator is provided and described in the next section.

  • 2-Slot USB/LXI Modular Chassis

    60-104-001 - Pickering Interfaces Ltd.

    This 2-slot USB/LXI modular chassis offers a small lightweight form factor, making it ideal for portable, benchtop, and space restrictive applications. The chassis is designed for desk or rack mounting and features remote control via USB or LXI Ethernet. Remote control over a network enables the switching function of a test system to be located as close as possible to the target equipment. The 60-104 chassis supports one or two 3U PXI modules and accepts Pickering's PXI products, it is the perfect platform to construct small scale applications. Possible systems include switching matrices up to 1104 crosspoints, 396 channel multiplexer or up to 36 channels of programmable resistor/sensor emulation.

  • 256 Channel Power Supply

    IDPS750 - Salland Engineering

    Salland Engineering’s Independent Device Power Supply (IDPS) can expand your existing Automated Test Equipment (ATE) with up to 256 independent DPS sources to increase parallel testing. It offers Force Voltage (FV) and Measure Current (MI) that can be used for continuity tests, parametric supply current (IDD) and quiescent supply current (IDDQ) measurements or simply for powering devices under test. The IDPS750 is targeted to reduce test costs for a wide range of applications including smart cards, memory, microprocessors and FPGA’s. Its design makes it useful in applications where many resources are required, or were the original ATE supplies do not meet your required specifications.

  • GPON ONT

    ONT-2GE-V-RFDW - Hangzhou Softel Optic Co., Ltd.

    2GE+1POTS+WiFi+CATV GPON/EPON HGU WiFi Mesh terminal devices are designed for fulfilling FTTH and triple play service demand of fixed network operators. These boxes are based on the mature Chipset (Realtek) technology, which have high ratio of performance to price, and the technology of IEEE802.11b/g/n/ac WiFi, Layer 2/3, Wi-Fi EasyMesh,and high quality VoIP as well. Support full management of HGU devices through SOFTEL OLT. They are highly reliable and easy to maintain, with guaranteed QoS for different service. And they are fully compliant with technical regulations such as IEEE802.3ah,ITU-T G.984.x and technical requirement of GPON Equipment from China Telecom.

  • Signal Chain µModule Receivers

    µModule® - Analog Devices Inc.

    Analog Devices µModule® (micromodule) receivers consist of high performance, high speed ADCs with fixed-gain, high speed amplifiers and antialias filters. Our integrated ADC and driver products include integrated bypass capacitance and simplify the high frequency layout required to preserve ac performance. The board space savings are significant for instrumentation applications such as spectrum analyzers, oscilloscopes ,and communications test equipment, or for communications applications such as high sensitivity receivers, software-defined radio (SDR), or signal intelligence receivers. Our portfolio uses system-in-package (SiP) technology similar to multichip modules (MCM) to integrate components with different technologies, along with passive components to make an integrated subsystem.

  • VLF Testing and Diagnostics Unit

    Frida TD - BAUR Prüf- und Messtechnik GmbH

    Cable testing and diagnostics with the BAUR frida TD. The portable and high performance high-voltage testing and diagnostics device is available in two different configurations: frida: Used for cable and cable sheath testing of medium-voltage cables and electrical equipment up to 20 kV. Another function is insulation testing on electrical equipment.frida TD: Expands the functional scope of frida with the tan delta diagnostics and Monitored Withstand Test (MWT) that combines the cable testing and dissipation factor measurement. This allows for an accurate and comprehensive assessment of the cable condition.* Cable testing and dissipation factor diagnostics in one device* Easy and quick test setup* Automatic testing and diagnostic sequences* Compact dimensions and lightweight

  • PXI 34x4 Signal Insertion and Monitor Matrix

    40-525A-001 - Pickering Interfaces Ltd.

    This is a PXI signal insertion and monitor matrix with switched pass thru connections on both X and Y axis. It is also availablein a 16x4 format and can be used for signal insertion and monitoring purposes on connections between the UUT and test system. Each pass thru connection from LX to X can be open or closed to allow the programmatic disconnection of the signal to check the response of the UUT. The matrix can be used to connect test equipment, such as a DMM or scope, to monitor the pass thru signals via Y connections while the LY connections can be used to insert a fault condition or insert external signals. When external signals are injected the LX connections can be opened and the LY connections closed.