Showing results: 571 - 585 of 1180 items found.
-
SG380 Series -
Stanford Research Systems, Inc.
The SG380 Series RF Signal Generators use a unique, innovative architecture (Rational Approximation Frequency Synthesis) to deliver ultra-high frequency resolution (1 µHz), excellent phase noise, and versatile modulation capabilities (AM, FM, ØM, pulse modulation and sweeps) at a fraction of the cost of competing designs.
-
Monarch Instrument
Smart Laser Sensor is an internal battery-powered optical sensor utilizing a visible Class 3R Laser for a TTL pulse output. Operating range up to 65 feet with reflective tape and up to 3 feet* (1 m) off contrasting color targets, key-ways, bolt heads or blades.
-
Liquid Instruments
Moku:ArbitraryWaveformGenerator can generate custom waveforms with up to 65k points and update rates of up to 1 GS/s. Waveforms can be loaded from a file or input as a piecewise-continuous mathematical function with up to 32 segments. In pulsed mode, waveforms can be output with more than 250,000 cycles of dead time between pulses.
-
GX1120 -
Marvin Test Solutions, Inc.
The GX1120 is a high performance, two-channel PXI arbitrary waveform generator that offers function generator and arbitrary waveform generator functionality within one instrument. Built-in waveforms are available for use with both the DDS or AWG modes of operation and include Sine, Triangle, Ramp, Noise, and pulse waveform generation.
-
V812 -
CAEN S.p.A.
The Mod. V812 is a 1-unit wide VME module housing a 16 channel constant fraction discriminator. The module accepts 16 negative inputs and generates precise ECL pulses when the input signals exceeds a given threshold: constant fraction technique allows to precisely determine the timing of the discrimination.
-
Pulse Instruments
Multiple timing signals ("clocks") are required by CCDs, IR FPAs, and some CMOS image sensors to transport electrical charge across the array to a sense amplifier for conversion into image data. Pulse Instruments offers a line of "clock drivers" for generating these timing signals. The parameters of these clocks (clock rate, pulse width, pulse amplitude, rise- and fall-times, etc.) greatly influence the behavior and performance of the imaging device. Our products take logic-level inputs from a pattern generator and allow the user to adjust the output parameters to suit their device and testing requirements. Clocks can be "tweaked" in real-time to determine optimal operating parameters for a particular device, or else programmed in accordance with a test plan for automated production test.
-
Insight Product Company
*Frequency band, GHz: 33-37 *Output power, typical, W: 10 (40 dBm) *Gain, dB, typical: 30*Gain flatness: 2 dB Max *Pulse width, Max.: 100 nanoseconds - 60 microseconds *Pulse reptition frequency: up to 100 KHz *Oprating temparture: -40 deg. Celsius to 60 deg. Celsius *Dimensions: 245 mm x 124 mm x 30 mm
-
IM 1910 Serie -
Ajinkya Electronic Systems
The IM 1910 Series Flow Loggers offered by us are micro controller based digital and highly versatile loggers. These can work with external flow sensors offering either electrical output like 4-20mA or 0-10 V or pulses and are used for measuring flow of different kinds of liquids, such as water, diesel & oils.
-
VCH-604 -
VREMYA-CH JS Company
High-Frequency Switch VCH-604 is designed for switching high-frequency (1 – 100 MHz) and pulse TTL signals. VCH-604 contains two groups of channels; each group has 25 inputs and 2 outputs. VCH-604 can be controlled from PC via GPIB and RS-232 interfaces or directly from front panel.
-
6602 -
VI Control Systems Ltd.
Interface board for converting signals on a National Instruments PCI/PXI 6602 timing board to and from fiber optic signals. Bursts, delayed pulses, and frequencies can be generated on outputs. The input channels can be used to measure frequency or period. Digital inputs or outputs can be substituted on channels that are not needed for timing purposes.
-
ZMAG CM -
Foerster Instruments, Incorporated
To avoid this, FOERSTER offer a powerful demagnetization unit: the ZMAG CM. The pulse method used enables high penetration depth to demagnetize the components effectively and promptly. The Siemens control and pre-configuration allows an easy integration of the unit into your production process. Thus, your process quality and reliability can be significantly increased.
-
HE950 -
Electro-Sensors, Inc.
Features • Square-wave pulse frequency output, NPN open-collector • Zero speed operation with no signal loss • 5-24 VDC powered • Gap sensing capability up to 3 mm • Senses broad range of ferrous targets (pulser discs / wraps with steel slugs, keyways, bolt heads, and gear teeth)
-
FM582 -
Sundance Multiprocessor Technology Ltd.
The offset adjustment does not clip the signal at the highest range (+/- 5V). That is why the “max input signal amplitude” has been specified as 10V, even though the selection of signal ranges only goes up to 5V. This way, a +10V pulse with -5V offset could still be digitised without clipping.
-
USBcount50 -
TEAM SOLUTIONS, INC.
USBcount50 is a new concept in USB Frequency Counter products. PC based frequency counters deliver many user benefits including flexibility, ease of use and economy. They are an invaluable tool during design and debug of digital circuits and can be used to quickly to verify generated frequencies, pulse widths and duty cycles .
-
MAE3 -
U. S. Digital
The MAE3 is an absolute magnetic kit encoder that provides shaft position information over 360 of rotation with no stops or gaps. This magnetic encoder is designed to easily mount to, and dismount from, an existing shaft to provide digital feedback information. The MAE3 is available with an analog or a pulse width modulated (PWM) digital output.