Showing results: 586 - 600 of 1180 items found.
-
CF106 -
Calmet Smart Calibration Devices
Universal miniature scanning head for detecting (counting) impulses from inductive, LED and LCD energy meters. Additionally it enables counting of manually triggered impulses (Start/Stop push button function). Sometimes (when access is difficult) it is the only way to count pulses from inductive, LED and LCD meters.
-
LD Class -
Teledyne OEM Solutions
The versatile LD Class consists of dual-headed, positive displacement piston pumps, delivering unmatched performance for analytical, flash, and small-scale preparative chromatography applications. With the patented SSI low dead-volume Pulse Dampener, advanced cam technology and dual piston mechanism, the LD Class provides virtually pulse-free operation.
-
Saluki Technology Inc.
Saluki S1433 series signal generator is a hand-held instrument specially designed for field testing. It has the functions of CW signal output, FM/AM/Pulse modulation, large dynamic range amplitude adjustment, step/list sweep etc. The integrated design of 8.4-inch large capacitive touch screen is convenient for users’ operation.
-
BDS-SM Series -
Becker & Hickl GmbH
*Pulse Width Down to 60 ps*Repetition Rate 20 MHz /50 MHz / 80 MHz / CW (Switchable)*Free Beam or Fiber Output*All Electronics Integrated*No External Driver Unit*Simple +12 V Supply*40 mm x 70 mm x 120 mm
-
Citizen Chiba Precision Co., Ltd.
*Use of Nd magnets allows excellent responsiveness and high output in a compact size.The rotor is evenly balanced to suppress mechanical vibrations.Uses slotless coils which prevent cogging and allow smooth revolutions, even at low speeds. *Miniaturization and inclusion of a high pulse encoder means highly precise positioning is possible.
-
CDN61000-5C -
Lisun Electronics Inc.
• Application Range: ≤4kV, 1.2/50us pulse, 8 wire unshielded twisted pair (UTP) • Test Voltage: Max 4KV, 2 kV (1.2/50 µs pulse when RJ45 connector is connected. Maximum test voltage is 1.5kV when RJ45 female is unconnected or auxiliary terminal is not protected.) • Coupling mode: 90V gas- discharge tube+250ohm Resistor/Each Wire, 8 Wires Simultaneously-Ground (Common Mode) • Input and output interface: RJ45 connector • Terminal layout (RJ45 connector): First pair of lines: pins 1/2 Second pair of lines: pins3/6 Third pair of lines: pins 4/5 Fourth pair of lines: pins 7/8 • Max. operating speed: 1000MBit/s • Max operating voltage: Max 50V DC • Max operating current: Max 1A Related Instruments
-
MFD350B -
Rinch Industrial Co.,Limited
Your product description goes here.MFD350B Portable Digital Ultrasonic Flaw Detector is a economical and practical model improved on MFD500B. Except for the differences of its measuring range, working frequency and transmitted pulse parameter, the other performances are the same as MFD500B.Based on ultrasonic pulse reflection testing principle, MFD350B controls all testing process by the mini-processor. And it has low power design and can do charge with two models such as online chargeing and offline charging. And it can work continuously about 8 hours.With large capacity, digital multi-color TFT LCD, original imported stable IC, small size, light weight, stable performance and favorable price, MFD350B is one of our company’s high promoted super cost performance and economically ultrasonic flaw detector.
-
Harpia-TF -
Light Conversion Ltd.
HARPIA‑TF is a time-resolved fluorescence measurement extension to the HARPIA‑TA mainframe that combines two time-resolved fluorescence techniques. For the highest time resolution, fluorescence is measured using the time-resolved fluorescence upconversion technique, where the fluorescence light emitted from the sample is sum-frequency mixed in a nonlinear crystal with a femtosecond gating pulse from the laser. The time resolution is then limited by the duration of the gate pulse and is in the range of 250 fs. For fluorescence decay times exceeding 150 ps, the instrument can be used in time-correlated single-photon counting (TCSPC) mode that allows for measuring high‑accuracy kinetic traces in the 200 ps – 2 μs temporal domain. HARPIA‑TF extension is designed around the industry leading Becker&Hickl® time-correlated single-photon counting system, with different detector options available.
-
ifm efector, inc.
*Encoder for precise position determination and linear measurement*Defined pulse sequence for the reliable detection of rotational speeds*Inclination sensors for precise measurement of angles of inclination on X and Y axes*High measurement accuracy across the total angular range in two axes*High protection rating for the requirements of harsh industrial environments
-
UVisIR Inc.
UVisIR'sreal-time long scanning autocorrelator measures laser pulses from femtosecond to picosecond. It is easy-to-use, real-time, dispersion-free, high-sensitivity and background-free! Long scanning range: 10fs-100ps. Real-time, dispersion-free and background-free scanning. High sensitivity: High-voltage(-1000VDC) PMT embeded! (Diode version is also available!). Broadband wavelength range: 500-1700nm.
-
Teledyne Defense Electronics
Teledyne RF & Microwave offers all types of detectors with both analog & threshold designs operating from 10MHz to 26GHz, with excellent power temperature stability.With over 50 ITAR-Free designs, many packaging options and with up to 10nS pulse response, Teledyne is able to offer the right detector for your particular application.
-
Spectrum Instrumentation
Digital I/O cards, pattern or pulse generators and digital data acquisition cards are all focused on digital signals. Input and output signals have two logic levels called low state (0) and high state (1). The electrical representation of these logical levels depends on the logic family and the supported I/O standard.
-
Circutor, sa
Solutions for monitoring and recording any value you wish to manage (electricity, water, gas consumption, temperatures, flow rates, pressures, units produced, etc.), either through communications or through pulse logger systems. The control system family contains the LINE solution to create a comprehensive energy management systems (SGEi), LM pulse loggers and MDC controllers to avoid surcharges in the electric bill by preventing the contracted capacity in electrical installations from being exceeded.
-
B1500A -
Keysight Technologies
Current-voltage (IV) measurement capabilities of spot, sweep, sampling and pulse measurement in the range of 0.1 fA - 1 A / 0.5 V - 200 VAC capacitance measurement in multi frequency from 1 kHz to 5 MHz and Quasi-Static Capacitance-Voltage (QS-CV) measurement capabilitiesAdvanced pulsed IV and ultra-fast IV measurement capability from minimum 5 ns sampling interval (200 MSa/s)Up to 40 V high voltage pulse forcing for non-volatile memory evaluation
-
Laurel Electronics, Inc
Designed to time single events or processes which produce start and stop pulses. Resolution to 0.2 s, duration from 1 s to 999,999 hours. Time may be displayed in HH.MM.SS clock format with 1 s resolution or in decimal H, M or S format with six-digit resolution. Multiple events can also be accumulated.