Showing results: 676 - 690 of 1180 items found.
-
Vektrex Electronic Systems
The Vektrex SpikeSafe™ DC / Continuous Pulse (DCP) Current Sources provide reliable DC or pulsed drive for LED or laser diode reliability testing, IESNA LM-80 maintenance testing, and other test applications requiring DC or continuous pulse current. Models support currents from 500mA to 60A and compliance voltages from 50V to 400V. All models feature individual channel control, accurate pulsing over long output cables, precise current, precision pulsing for improved measurement repeatability, and high power density — typically 6.4kW-8kW.
-
Thermo Fisher Scientific Inc.
Identify and help correct ESD and latch-up susceptibility issues on sensitive integrated circuit components prior to full-scale production with the Thermo Scientific™ MK.2-SE ESD and Latch-Up Test System. The MK.2-SE test system provides advanced capabilities to test high pin count IC devices to Human Body Model (HBM) and Machine Model (MM) ESD standards. The system’s pulse delivery design addresses wave form hazards such as trailing pulse and pre-discharge voltage rise, and performs Latch-Up testing per the JEDEC EIA/JESD 78 Method.
-
MFCh -
Holding Informtest
*Frequency reproduction accuracy ± 2 x 10 -9 *Output frequency 1 Hz - 10 MHz *Output pulse signal 1 kHz The MFC is designed to generate high-frequency pulse signals with a frequency of 1 kHz and a frequency in the range from 1 Hz to 10 MHz along two output lines. The MFC is designed to operate in measuring systems based on the VXIbus trunk. In the MFC, a rubidium frequency standard is used as a reference frequency source. Time to reach the mode when the power source of the rubidium standard is turned on, no more than 10 min
-
TM1000 -
T&M Tools Limited Co
Designed to aid in the testing of fiber optic cable when using an OTDR. The OTDR LaunchFiber box is used with Optical Time Domain Reflectometers (OTDR's) to help minimize the effects of the OTDR's launch pulse onmeasurement uncertainty.
-
MPA-XL -
CDP Systems Corp.
MPA-XL is a cost-effective terawatt Ti: sapphire amplifier system. It gives up to 200 mJ energy of the stretched pulse and further compression with 65% efficiency. A standard air compressor can be placed into a custom designed vacuum chamber.
-
CYHCS-LF -
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for accurate measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor.
-
5120A -
Peaceful Thriving Enterprise Co Ltd
*With CE, GS and UKCA Approval.*Operates by two LR41, 1.5V batteries.*Test for voltage, continuity.*By contact method, check on 110-250V AC.*By non-contact method, check on 110-500V AC.*Detecting pulse of the high-tension ignition
-
Avtech Electrosystems, Ltd.
These instruments generate current pulses whose amplitude is largely independent of the load voltage. This makes them ideal for pulsing device whose voltage may vary with time (for instance, the voltage drop of laser diodes may vary with temperature, or explosive squibs which change impedance during ignition). This voltage independence is a trade-off with speed. If faster rise times are required, consider using pulsed voltage instruments instead.
-
Badger Meter
Cox FC30 flow computers service both liquid and gas applications. The FC30 features batching, 40-point flow meter linearization tables, and temperature viscosity correction using Strouhal/Roshko advanced linearization methods and multiple flow and control inputs. Relay outputs are independently assignable for alarms and general purpose warnings. The FC30 has serial communications, both RS232 and 485, and isolated analog and pulse outputs.
-
FG-274 -
Texio Technology Corp.
* Output Waveforms of Sine, Square, Triangle and Pulse.* The design of DDS and FPGA technology provide high quality waveforms.* High frequency stability and accuracy: 20ppm.* Low Distortion at -55dBc.* Wide output frequency range: 4MHz* Maximum frequency resolution of full range: 100mHz.* TTL/CMOS output* Variable DC offset control* Variable Duty ratio control* Output overload protection* Store/Recall function
-
SICK Sensor Intelligence
Versatile, compact and flexible – Incremental encodersIncremental encoders are used when retention of absolute position upon power loss is not required. These encoders provide information about the position, angle and number of revolutions. The number of lines per revolution determines the resolution. The current position can be determined by counting these pulses from a reference point. Upon activating the machine, a reference run to the reference point is required to determine the absolute position of the encoder.
-
CSpark Research
The MCA1K is a compact multi channel analyzer (MCA) for processing gaussian inputsIt is capable of sorting input pulses from shaping amplifiers into 512 discrete bins.Each Bin can record up to 16M counts before an overflow event occurs.The unit is powered via USB , and the data can be visualized via the included Python based software.The software also includes analytical tools to fit the data and extract parameters
-
Series 18 -
Electro-Sensors, Inc.
Features • Square-wave pulse frequency output • NPN or PNP output options • Single channel or bi-directional options • 5-24 VDC powered • Hall Effect or Magnetoresistive sensing options • Standard and wide temperature options • Rugged M18x1 stainless steel sensor housing (all models) • Four housing options • All sensors are epoxy filled and sealed against liquids and dusts • Works with Electro-Sensors magnetic pulser discs/wraps
-
MesaPhotonics, LLC
Our autocorrelator is designed for those who do not require the sophisticated pulse characterization provided by our FROG Scan systems. Mesa Photonics' autocorrelators are built around the same advanced servo motor used in our FROG Scan systems and can be upgraded later to a complete FROG Scan or FROG Scan Ultra by purchasing a conversion kit. The servo motor precision corresponds to 1 fs temporal steps.
-
IWATSU Electronic Co., Ltd.
*Switching current waveform and pulse response characteristics of power devices*Current measurements of inverter system*AC current measurements (at large DC offset)*Impulse high current measurements*Bus Bar high current measurements