40-782B-532 -
Pickering Interfaces Ltd.
The 40-782B-532 (PXI) and 42-782B-532 (PXIe) dual transfer switches are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50Ω and a maximum operating frequency of 26.5GHz. Connections are made via front panel mounted high quality SMA coaxial connectors.
-
40-788-021-E -
Pickering Interfaces Ltd.
The 40-788-021-E (PXI) and 42-788-021-E (PXIe) are single failsafe SP8T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-021-E -
Pickering Interfaces Ltd.
The 40-788-021-E (PXI) and 42-788-021-E (PXIe) are single failsafe SP8T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-041-E -
Pickering Interfaces Ltd.
The 40-788-041-E (PXI) and 42-788-041-E (PXIe) are single failsafe SP8T 26.5 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-041-E -
Pickering Interfaces Ltd.
The 40-788-041-E (PXI) and 42-788-041-E (PXIe) are single failsafe SP8T 26.5 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
Pickering Interfaces Ltd.
The 40-788-121-E (PXI) and 42-788-121-E (PXIe) are single failsafe SP10T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-131-E -
Pickering Interfaces Ltd.
The 40-788-131-E (PXI) and 42-788-131-E (PXIe) are single failsafe SP10T 22 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-221-E -
Pickering Interfaces Ltd.
The 40-788-221-E (PXI) and 42-788-221-E (PXIe) are single failsafe SP12T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-221-E -
Pickering Interfaces Ltd.
The 40-788-221-E (PXI) and 42-788-221-E (PXIe) are single failsafe SP12T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-121-E -
Pickering Interfaces Ltd.
The 40-788-121-E (PXI) and 42-788-121-E (PXIe) are single failsafe SP10T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-121-E -
Pickering Interfaces Ltd.
The 40-788-121-E (PXI) and 42-788-121-E (PXIe) are single failsafe SP10T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-131-E -
Pickering Interfaces Ltd.
The 40-788-131-E (PXI) and 42-788-131-E (PXIe) are single failsafe SP10T 22 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-011-E -
Pickering Interfaces Ltd.
The 40-788-011-E (PXI) and 42-788-011-E (PXIe) are single failsafe SP8T 8 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-011-E -
Pickering Interfaces Ltd.
The 40-788-011-E (PXI) and 42-788-011-E (PXIe) are single failsafe SP8T 8 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-132-E -
Pickering Interfaces Ltd.
The 40-788-132-E (PXI) and 42-788-132-E (PXIe) are dual failsafe SP10T 22 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.