Showing results: 856 - 870 of 1779 items found.
-
42-880B-001 -
Pickering Interfaces Ltd.
The 40-880B-001 (PXI) and 42-880B-001 (PXIe) are dual SPDT 50Ω RF switches with 8GHz bandwidth. The 40/42-880B range has automatic termination of unused signals and are available as a dual switch in 1 slot, a quad switch in a two slots or hex and octal switches in three slots.
-
40-782B-552 -
Pickering Interfaces Ltd.
The 40-782B-552 (PXI) and 42-782B-552 (PXIe) dual transfer switches are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50Ω and a maximum operating frequency of 50GHz. Connections are made via front panel mounted high quality SMA-2.4 coaxial connectors.
-
42-788-211-E -
Pickering Interfaces Ltd.
The 40-788-211-E (PXI) and 42-788-211-E (PXIe) are single failsafe SP12T 8 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-211-E -
Pickering Interfaces Ltd.
The 40-788-211-E (PXI) and 42-788-211-E (PXIe) are single failsafe SP12T 8 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-042-E -
Pickering Interfaces Ltd.
The 40-788-042-E (PXI) and 42-788-042-E (PXIe) are dual failsafe SP8T 26.5 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-022-E -
Pickering Interfaces Ltd.
The 40-788-022-E (PXI) and 42-788-022-E (PXIe) are dual failsafe SP8T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-042-E -
Pickering Interfaces Ltd.
The 40-788-042-E (PXI) and 42-788-042-E (PXIe) are dual failsafe SP8T 26.5 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-022-E -
Pickering Interfaces Ltd.
The 40-788-022-E (PXI) and 42-788-022-E (PXIe) are dual failsafe SP8T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-222-E -
Pickering Interfaces Ltd.
The 40-788-222-E (PXI) and 42-788-222-E (PXIe) are dual failsafe SP12T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-122-E -
Pickering Interfaces Ltd.
The 40-788-122-E (PXI) and 42-788-122-E (PXIe) are dual failsafe SP10T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-132-E -
Pickering Interfaces Ltd.
The 40-788-132-E (PXI) and 42-788-132-E (PXIe) are dual failsafe SP10T 22 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-012-E -
Pickering Interfaces Ltd.
The 40-788-012-E (PXI) and 42-788-012-E (PXIe) are dual failsafe SP8T 8 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-222-E -
Pickering Interfaces Ltd.
The 40-788-222-E (PXI) and 42-788-222-E (PXIe) are dual failsafe SP12T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-112-E -
Pickering Interfaces Ltd.
The 40-788-112-E (PXI) and 42-788-112-E (PXIe) are dual failsafe SP10T 8 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-122-E -
Pickering Interfaces Ltd.
The 40-788-122-E (PXI) and 42-788-122-E (PXIe) are dual failsafe SP10T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.