Showing results: 271 - 285 of 508 items found.
-
Procter & Chester Measurements Ltd
Pressure: Measures gas or liquid pressure. Pressure is an expression of the force required to stop a fluid from expanding. The transducer generates a signal from the pressure imposed upon it. Torque: Measures the torque (or twisting motion) on a static or rotating system. The static torque element has little movement and therefore more economic to manufacture and purchase. Rotary or dynamic torque is more complicated as the signal needs to be transferred using slip rings, wireless telemetry or rotary transformers/inductance technology so that the strain gauged shaft can continuously rotate. Displacement: Measures distance. The displacement transducers that PCM offer are slightly different to standard units. They have a strain gauge/wheatstone bridge. The benefit here is that if the customer has existing electronics that uses strain gauge/load cell technology, they can use them with these sensors.
-
Load Cell Central
We carry a wide range of digital displays for strain gage load cells. There are many options available to our load cell displays such as analog outputs to interface with a PLC, digital outputs for computer interfaces, I/O and relay outputs to control batching and checkweighing scales, and wireless load cell indicators.
-
LCT-U -
Thames Side Sensors Limited
The Advanced Diagnostic Load Cell Tester Model LCT-U is a stand-alone hand-held device specially designed for fast, comprehensive troubleshooting of strain gauge load cells. The LCT-U can quickly diagnose problems with all common types of load cell available today, including 6-wire load cells (with sense wires).
-
Dynamic Load Monitoring Ltd.
The Detrenching Grapnel is manufactured from high tensile steel, suitable for withstanding the harsh offshore environments. The structure and material of the grapnel is tested using finite element analysis which is performed during the design phase. This simulates the various stresses and strains acting on the grapnel in a variety of differentseabed conditions and allowed for optimisation of the design.
-
410112739 -
Virginia Panel Corporation
Enclosure, Part # 410 112 739 gives you the ability to discrete wire to your UUT with secure strain relief provided by the cable clamps located on the back end. Once the cable clamps are open, you can remove the stiffener bar and install or remove cables without unplugging patchcords from the assembly.
-
Laurel Electronics, Inc
A high-sensitivity 5-digit meter for use with load cells, strain gauges and microvolt input signals where high accuracy and stability are required. Load cell operation allows 4- or 6-wire hookup and display in engineering units, such as lbs, kg or psi. Built-in excitation for up to four 350-ohm load cells in parallel.
-
Metra Mess- und Frequenztechnik in Radebeul e.K.
There are models with charge output and with IEPE compatible voltage output. The transducers of KS series have a shear type sensing element making them less susceptible to thermal transients and base strain. The accelerometers of KD series have a compression type sensing element combining rugged design, precision and low cost.
-
Encore Electronics, Inc.
Encore Electronics manufactures a wide range of analog signal conditioning equipment, including strain gage and pressure amplifiers, frequency-to-voltage converters, thermocouple isolation amplifiers and anti-aliasing filters.
-
Technica Optical Components, LLC
The T150 is a ruggedized high temperature non-metallic cable sensor designed for monitoring distributed temperatures and strains in environments to 260 Degrees Celsius with submillisecond response time. High temperature resistant non-metallic sensor. Ideally suited for applications where there is concern that the high temperature or chemical composition of the surrounding environment will cause damage to the sensors.
-
B068VFX-6F-0A -
Pickering Interfaces Ltd.
This connector block provides a simple method of connecting to high density 68 Way VHDCI connectors. The screw terminals use a rising cage clamp mechanism to minimize risk of copper strand breakage. Users should make their own cable strain relief arrangements and ensure appropriate electrical safety precautions are observed.
-
Lloyd Material Testing
The VE1 is a high precision video extensometer that uses a non-contacting optical measurement based on a digital camera and real time image processing to measure the longitudinal and transversal strain during tensile tests.
-
AMETEK Sensors, Test & Calibration
The VE1 is a high precision video extensometer that uses a non-contacting optical measurement based on a digital camera and real time image processing to measure the longitudinal and transversal strain during tensile tests.
-
Lord MicroStrain Sensing
As one of the first companies to utilize wireless sensor capabilities to allow digital sensors to interact with personal computers and the internet, LORD Microstrain® wireless sensor networks (WSN) enable simultaneous, high-speed sensing and data acquisition from multiple wireless strain gauges, accelerometers, temperature, and millivolt inputs for a variety of applications and industries.
-
2518/2519TDIN -
Sensoray Co., Inc
8 or 16 differential thermocouples, RTD's, strain gauges, thermistors, resistance, 4-20 ma, or voltage inputsIncludes screw terminals for field wiring10-Base-T Ethernet server with embedded TCP/IP stackIncludes interface DLLSingle supply operationEach channel is software programmable for sensor type, gain, low-pass filtering, scan rateOptional NEMA Enclosure
-
92-960-020-10A-F -
Pickering Interfaces Ltd.
This accessory is designed to allow users to directly terminate a cable with soldered connections to the connector. It is supplied with removable solder bucket contacts suitable for wires up to 16 AWG. When the product is used without a backshell users should make their own cable strain relief arrangements and ensure appropriate electrical safety precautions are observed.