42-190C-012 -
Pickering Interfaces Ltd.
The 40-190C-012 (PXI) and 42-190C-012 (PXIe) are fault insertion switches with 74 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
40-196-001 -
Pickering Interfaces Ltd.
The 40-196 is a 10 Channel 5A Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Shorting relays on each channel enable UUT signals to be subjected to external user applied fault conditions or to be shorted to the adjacent signal in the same channel. Relays in line with the signal allow open circuit conditions to be simulated on either side or both sides of a channel signal pair. The switching topology of the 40-196 allows channels to be interconnected so that complex fault insertion systems can be constructed.
-
40-192A-012-HI -
Pickering Interfaces Ltd.
The 40-192A-012-HI is a PXI fault insertion switch with hardware interlock using solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test:
-
40-191B-012-HI -
Pickering Interfaces Ltd.
The 40-191B-012-HI is a PXI fault insertion switch with hardware interlock using solid state switching elements and is capable of carrying 40A on single channel or 30A on all channels at the same time and provides a robust solution to high current fault insertion.
-
40-193A-001-HI -
Pickering Interfaces Ltd.
The 40-193A-001-HI is a 7-Channel Fault Insertion switch with hardware interlock and one fault bus, designed for the simulation of fault conditions in automotive systems. The module is capable of switching current up to 20A.
-
40-193A-002-HI -
Pickering Interfaces Ltd.
The 40-193A-002-HI is a 7-Channel Fault Insertion switch with hardware interlock and two fault buses, designed for the simulation of fault conditions in automotive systems. The module is capable of switching current up to 20A.
-
778572-10 -
NI
68-Channel, 2 A PXI Signal Insertion Switch Module—The PXI‑2510 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2510 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls
-
Sensorform OFI-FLS -
Suparule Systems Ltd.
The Sensorform OFI-FLS is a Fault Passage Indicator for Overhead Lines, which is designed to assist in the rapidlocation and isolation of faults on Medium Voltage networks (1-38kV). When the current in the phase exceeds a preset level, the fault is indicated by means of both a mechanical flag indicator and high-intensity LED indicators.
-
LineTroll 110Eμ -
Nortroll
Linetroll 110E contains magnetic and electric field sensors surveying line current and line voltage. The magnetic sensor automatically adapts to line current, detecting preset current increases. The electric field sensor is monitoring the presence of line voltage. The sensor signals are processed and compared with user set alarm criterias.
-
LineTroll R400D -
Nortroll
LineTroll R400D Fault Indicator indicates earth- and short-circuit faults and can distinguish between permanent and transient faults. The indicator has two sensors and use both the electrical field and the magnetical field to detect faults on all three phases.
-
STB Electrical Test Equipment, Inc
From the company who builds the popular analog ground fault detector comes the newest phase rotation indicator on the market. No other manufacturer offers a phase rotation indicator like STB's DX2 that will read up to 5kV! The phase rotation indicator is used to determine the phase sequence of three-phase voltages. This meter is most commonly used for phasing-in a power line which has supplied power to motors and plants. It is essential for testing departments of public utility systems for laboratory and field testing. The convenient and durable carrying case allows user to safely transport the unit to wherever the job takes them.