Showing results: 16 - 30 of 623 items found.
-
Supreme Instrument Laboratories
Calibrator for calibration and testing of A.C. Milliammeters, Ammeters, Voltmeters, and D.C. Microammeters, Milliammeters, Ammeters, Millivoltmeters and Voltmeters having following technical specification
-
Dynamic Systems Inc.
Used for applications that require high temperatures (1800C-2000C) for extended periods of time, the High Temperature Mobile Conversion Unit offers enhanced capabilities to accommodate more damanding requirements.The unit is based on the General Purpose MCU which allows for the use of standard specimen grips and accesories.
-
Bird Dog 3 - 3 Channels -
Seismic Source Co.
*32-bit, high speed, ADC chip for lower noise and increased accuracy*Three different operation with a single unit*8 Gigabytes of Data Storage, Expandable to 16*GPS based time and location saved for every record*Stable and rugged unit for use in all conditions*Three-Component Test Mode, checks 3 elements at onceto save time and effort*All test data saved in non-volatile memory for later download and retrieval*Connects to PC via Ethernet or optional Wi-Fi, provides control, data download and real time display and analysis of data and results
-
PX773x -
VX Instruments GmbH
The PX773x is a high precision, high speed source and measurement unit, which is designed for automated high throughput testing.
-
PXS840x -
VX Instruments GmbH
The PXS(e)840x is a high precision, high speed source and measurement unit, which is designed for automated high throughput testing.
-
DIO2 -
APPLICOS
The DIO-II module is a multimode digital source and capture unit. In Low Speed Mode it provides a 20-bit parallel or 24-bit serial I/O capability running at speeds up to 50 MHz. In High Speed Mode, the DIO-II provides a 16-bit parallel I/O capability up to 200 MHz. In both Modes, the Clock is generated by a low jitter PLL source that is capable of generating clocks from 320 kHz up to 1 GHz.
-
40-201-004 -
Pickering Interfaces Ltd.
This high bandwidth differential fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
40-201-008 -
Pickering Interfaces Ltd.
This high bandwidth differential PXI fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
40-190B-402 -
Pickering Interfaces Ltd.
The Dual Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel.
-
40-190B-302 -
Pickering Interfaces Ltd.
The Dual Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
40-190B-502 -
Pickering Interfaces Ltd.
The Dual Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel.
-
PXS(e)840x -
VX Instruments GmbH
The PXS840x PXI SMU family is a high-speed, 4-quadrant source measure unit. Carry out measurements directly on the DUT with the integrated CMU and VMU.
-
50-190-201 -
Pickering Interfaces Ltd.
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
50-190-001 -
Pickering Interfaces Ltd.
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
50-190-101 -
Pickering Interfaces Ltd.
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.