778572-21 -
NI
40-Channel, 2 A, DPST PXI Relay Module—The PXI‑2521 is a general-purpose switch module that features independent double‑pole single‑throw (DPST) armature relays. Each relay is nonlatching with very low on-resistance and low thermal offsets. The PXI‑2521 is fully software programmable, and it supports onboard relay count tracking. With an efficient coupling of voltage/current capability and relay density, this switch module is ideal for automated test equipment (ATE) loads or for controlling heaters, lights, and fans.
-
778572-70 -
NI
40-Channel, 1 A, SPDT PXI Relay Module—The PXI‑2570 is a general-purpose switch module that features independent single‑pole double‑throw (SPDT) Form C armature relays. Each relay channel has a normally closed (NC), normally open (NO), and common (COM) terminal.
-
778572-69 -
NI
31-Channel, 2 A, SPST PXI Relay Module—The PXI‑2569 is a general-purpose switch module that features independent single‑pole single‑throw (SPST) Form A armature relays. It is fully software programmable and contains a 32,000‑step scan list for deterministic scanning capability. This module offers maximum relay density, so it is ideal for medium-power automated test loads.
-
778572-68 -
NI
31-Channel, 2 A, SPST PXI Relay Module—The PXI‑2568 is a general-purpose switch module that features independent single‑pole single‑throw (SPST) Form A armature relays. Each relay is nonlatching with very low on-resistance and low thermal offsets. The PXI‑2568 is fully software programmable. With an efficient coupling of voltage/current capability and relay density, this switch module is ideal for automated test equipment (ATE) loads or for controlling heaters, lights, and fans.
-
GX6196 -
Marvin Test Solutions, Inc.
The GX6196 is a 6U PXI switch and control board that can be used to create custom switching, signal conditioning, or specific UUT control interfaces. The board provides 96, 2 pole, form A relays, 8 digital I/O lines, and a serial digital interface. All of these resources are available via (5) inter-board connectors which interface to the user defined daughter / mezzanine board. The mezzanine board provides all connections to the unit under test (UUT) via two 78 pin D-sub connectors. The GX6196 is supplied with a front panel which accepts (2) 78 pin D-sub connectors.
-
40-780A-522 -
Pickering Interfaces Ltd.
This PXI microwave module is part of a range that gives you the highest RF & microwave switching performance available. Applications are mainly in the microwave region, however there are many uses in the RF spectrum where extremely low insertion loss and ultra high isolation are critical, they may also be used for lower frequency RF applications where power handling to 240W is required (700W for N-Type options).
-
42-780B-524 -
Pickering Interfaces Ltd.
The 40-780B-524 (PXI) and 42-780B-524 (PXIe) are quad failsafe SPDT 18 GHz unterminated microwave relay modules. The 40/42-780B range is available with one, two, three or four SPDT switches capable of switching frequencies up to 67 GHz in 50 Ω or 2.5 GHz in 75 Ω. Connections are made via front panel mounted high quality RF coaxial connectors, SMA or N-Type for 50 Ω and 1.6/5.6 in 75 Ω versions. Remote versions are also available which can support up to three SPDT relays in a single slot.
-
-
PXI-7901 -
ADLINK Technology Inc.
ADLINK PXI-7901 is a general-purpose (GP) switch module implementing 16-CH independent single-pole double-throw (SPDT) relays (1 Form C). PXI-7901 can connect one input to one output and be used as signal switching and routing for measurement system or ATE. Thanks to its high switching capacity, PXI-7901 can also be used to turn on or turn off devices such as motors, fans, heaters, and lights. The contact position of the relays can be changed either by direct software commands or by following the instructions previously stored in the on-board scan list. The scan list advances upon the trigger from external measurement devices, such as a DMM. The scan list could also advance when the scan-delay timer expires. In the PXI-7901, PXI trigger functions are supported and software programmable. Multiple modules can therefore be synchronized without additional field wiring.
-
1260-13 -
Astronics Corporation
The Astronics 1260-13 offers general purpose signal switching and control of external devices. The module provides 40 channels of DPST switches.
-
781420-16 -
NI
8x46, 0.3 A, Reed Matrix Module for SwitchBlock - The SWB‑2816 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, … individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.
-
781421-17 -
NI
16x22, 0.3 A, Reed Matrix Module for SwitchBlock - The SWB‑2817 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.
-
781420-17 -
NI
16x22, 0.3 A, Reed Matrix Module for SwitchBlock - The SWB‑2817 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.
-
781421-16 -
NI
8x46, 0.3 A, Reed Matrix Module for SwitchBlock - The SWB‑2816 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.
-
781421-15 -
NI
4x86, 0.3 A, No Row Access, Reed Matrix Module for SwitchBlock - The SWB‑2815 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.