Showing results: 1321 - 1335 of 2443 items found.
-
Festo Corporation
Voltage 0...250V DC, 230 V AC Cable length 0.3, 2.5, 5, 7.5, 0.2...10 m Plug connection M8, M12 / female thread M5 Electrical Via reed contact Contactless PNP, NPN Pneumatic.
-
Sequoia Series -
AMETEK Programmable Power, Inc.
The California Instruments Sequoia Series combines intelligence and flexibility with high power to create an advanced platform of AC solutions. Using a state-of the-art SiC power switching architecture, this full four quadrant product combines compactness, robustness, and functionality in a floor-standing chassis.
-
СВС-50М (СВС-100М) -
Kharkovenergopribor Ltd.
CBC-M-series systems are designed for high-voltage testing of electrical protective equipment and insulated hand tools. Withstand tests are carried out with AC voltage (CBC-50M: UAC ≤ 50 kVRMS; CBC-100M: UAC ≤ 100 kVRMS) at industrial frequency (f = 50 Hz).
-
MEET International Ltd.
*Detects AC voltage by non-contact method: 70VAC to 250VAC*Finds broken wire location*Wrong connection check*Ground / Earthing disconnection check*Detects static radiation of TV / monitor*Checks operating condition of ionizer*Microwave leakage detection: ≥5mw/cm2
-
1998B -
Peaceful Thriving Enterprise Co Ltd
The 2 pole Voltage Tester provides a clear indication of AC or DC voltages levels via bright LED's from 6V to 600V. It is constructed in accordance with the latest safety standards and is ergonomically designed which is durable enough for both industrial and domestic uses.
-
DU3315/3316 -
Delta United Instrument Co., Ltd.
3 in 1 tester with AC, DC, IR functions ( IR function is optional for DU3316 only)ARC Detction:DU3315 /DU3316 Standard function40 x 4 LCD text displayFast cut-off time : 0.4ms5 sets of memory, 3 steps for each memory
-
CB-300A -
ELMA Electronic, Inc.
3U centrifugal 300 cfm blower for pressurizing consoles, computers and electronic systems with cool, filtered air. Includes easy-to-remove, washable dust filter, 3-conductor AC cord and removable, brushed aluminum grille. Installs on 19” panel mounting rails.
-
CB-500A -
ELMA Electronic, Inc.
7U centrifugal 500 cfm blower for pressurizing consoles, computers and electronic systems with cool, filtered air. Includes easy-to-remove, washable dust filter, 3-conductor AC cord and removable, brushed aluminum grille. Installs on 19” panel mounting rails.
-
325 SVD -
Standard Electric Works Co., Ltd
● Compact, easy to wear and convenient in use● Designed for indoor and outdoor use● Water-proof design. (IP65)● Equipped with self-testing functions● Able to sense all kinds of AC High Voltage System● Low power consumption● CE Certifiedright LED visual indication
-
1251 -
Ballentine Laboratories, Inc.
The BLI Series of Micropotentiometers consist of a Model 1251 terminating resistor and a Model 1351 Thermoelement housing. These micropots are true RMS current to voltage converters for calibrating AC instruments. The NIST calibration range is from dc to 500 MHz (available to 1.2 GHz)
-
Klein Tools, Inc.
Voltage testers detect a wide range of AC voltage in overhead conductors with both audible and visual signals. Available in dual range and broad range, these testers are water resistant and include a durable carrying case, meaning they can be taken along and used on a variety of jobsites.
-
LX-08 -
Link Instruments
The LX-08 series of high voltage logic analyzer adapters provides a safe isolated method of measuring high voltage control signals with a low voltage logic analyzer. All inbound signals are optically isolated and attenuated to a safe level for the delicate inputs typically found on logic analyzers. The inputs on the LX-08 are capable of withstanding voltages up to +/- 300V AC/DC, higher voltage configurations are available upon request. Rather than probing with multiple neon screwdrivers, the LX-08 can provide simultaneous viewing of up to 8 circuits in the STANDALONE mode via the indicator array. Need to catch a transient event or map out a timing sequence? Just add a logic analyzer to the outputs of the LX-08 and turn it into a high voltage logic analyzer. High voltage signals that were hazardous for a logic analyzer can now be measured safely. Typical outputs of a high speed PLC sequencer can be precisely timed and measured from both sides of the control relay. With the built in user selectable AC filter circuit, an AC signal can be measured as DC events or AC cycles.
-
Mors Smitt Group
*Heavy duty Elkonite contact tips*AC and DC versions available*AC versions available with or without internal rectifier PCB*Automated vision system and operator inspection*Comprehensive automated end of line testing*Test Certificates supplied with each relay*Certificate of Conformity supplied with each order*Recertification and repair services available
-
ECTS2 -
Adaptive Power Systems, Inc.
Now in its second generation, the ADAPTIVE POWER EMC Compliance Test Systems use a greatly enhanced harmonics and flicker measurement system and newly designed flicker impedance options to support single and three phase AC harmonics, flicker and AC and DC immunity compliance testing up to the maximum required current of 75A per phase.
-
Extech BTL10 -
Extech Instruments Corporation
The Extech BT100 is a Battery Capacity Tester. This product can be used to test the condition of batteries both quickly and easily. As an AC milliohm meter, the tester measures DC voltage and AC resistance while the battery is in use, helping to save time on repetitive testing trials or large quantities of batteries. Includes PC software for downloading readings to a PC.