Showing results: 616 - 630 of 1583 items found.
-
Eiden Co., Ltd.
This device is equips with the simulator. The following condition can be simulated. Non Liner: Non-linear assumed the satellite repeater - AWGN: C/N assumed the rain attenuation.- Phase Noise: Phase noise assumed the LNB - Frequency Drift: Frequency drift assumed the LNB- Echo: Reflection by the reception wiring and so on The MPEG-2 TS and the TLV (Type Length Value) can be transmitted. The test stream generator is equipped. Thus, the files can be rewritten through the USB2.0 interface. A seven-inches WVGA touch-panel is equipped. Thus, an excellent operation ability is provided. The remote control through the Ethernet is possible.
-
Teledyne RF & Microwave
Teledyne RF & Microwave IQ Demodulators are fully space-qualified designs providing stringent phase and amplitude matching, and superior output third order intercept performance. To meet high LO and IF rejection requirements diplexers are used at the I and Q ports. All components and processing fully meet MIL-PRF-38534, Class K and MIL-DTL-28837. Teledyne RF & Microwave can provide performance to meet most receiver system requirements, including single or moving LO frequencies and tight phase and amplitude matching. Customers can specify our designs for space, military, or commercial applications.
-
Teledyne Lincoln Microwave
Four port devices can be realized by joining two 3 port devices via the appropriate ports. As system performance requirements become more demanding, new design approaches must be adopted. These include Faraday rotation devices and phase shift circulators. The bandwidth and isolation limitations of 3 port devices are overcome through a distributed architecture that enables more ferrite material to be incorporated into the transmission path, thereby achieving an increase in the biasing magnetic field. Phase shift circulators can be designed to handle higher RF power than 3-port devices.
-
61610 -
Chroma Systems Solutions, Inc.
Power Rating:61511/61611: 12KVA61512/61612: 18KVAVoltage Range: 0-150V/0-300V / AutoConfigurations with input voltage of 220V or 480VFrequency: DC, 15Hz-1500HzSingle-phase or three-phase output selectableProgrammable slew rate setting for changing voltage and frequencyProgrammable voltage and current limitHigh output current crest factor, ideal for inrush current testingTurn on, turn off phase angle controlTTL signal which indicates output transientComprehensive measurement capability, including current harmonicsAnalog programmable interfacesRemote interface: GPIB, RS-232, USB and EthernetCapable of delivering power output up to 90KVA by implementing Master-slave parallel operation
-
1813 EL -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2 Lines × 16 characters LCD.● Very low consumption.● Suitable for domestic version.● Better than 3% accuracy (current).● Menu-driven.● Accurate digital readout of disconnection time.● Accurate digital readout of disconnection sensitivity.● Automatic data hold function.● Zero crossing circuitry permit testing at 0° or 180°.● Disconnection phase polarity shown on LCD display.● Auto off and off override.● Polarity trip indicator (positive or negative phase)● Wiring polarity indicator.● Measure voltage between Line and Earth before testing.● 60Hz available.
-
NF Corp.
Detecting and measuring AC signal''s amplitude or phase buried in noise, as high sensitive AC Voltmeter with noise immunity.This equipment is used by many customers like at the fields of physics and science including spectroscopic analysis.
-
SR620 -
Stanford Research Systems, Inc.
The SR620 measures time interval, frequency, pulse-width, rise and fall time, period, phase and events. Time intervals are measured with 25 ps rms resolution, making the SR620 one of the highest resolution counters available.
-
APS-4000 -
Matrix Technology Inc.
APS4000 Series is an AC power source from 350VA to 1200VA, output frequency: 45Hz-250Hz continuously adjustable (special frequency can be customized); Output phase voltage: withstand 1V-150VAC, high-grade 151V-300VAC, automatic gear 1V-300V.
-
PADL6 -
GigaBaudics Co.
The PADL6 is a programmable delay line instrument designed for adjusting the time delay or phase of radio, microwave or even digital signals with bandwidths from DC to 6 GHz. Delays are controlled via a TTL level bus.
-
ERAVANT
A Scalar Network Analyzer is a type of RF network analyzer that is used to measure only the amplitude properties of a DUT (Device Under Test). Unlike a Vector network Analyzer, it does not measure both amplitude and phase of the DUT.
-
Qualitrol
Qualitrol Bushing Monitor System is an on-line Tanδ (PF) and Capacitance monitoring system for substation bushings. It measures the phase difference induced by capacitive layers of bushings and calculates the rate of change to predict defects in bushing insulation.
-
S95083B -
Keysight Technologies
The Keysight S95083B measurement software includes the scalar mixer / converter plus phase (SMC+Phase) measurement class. It provides fully calibrated conversion gain / loss, relative phase, and absolute group delay measurements of mixers and converters without the need for reference or calibration mixers. Eliminating the calibration mixer requires a U9391C / F / G comb generator and an external DC power supply. A vector mixer characterization (VMC) is also included for measuring group delay of frequency-converting devices. VMC can be used to characterize a user-supplied calibration mixer.
-
DARE Electronics
DARE has a complete line of AC or DC operated power monitors available in numerous package styles including 50 Hz, 60 Hz, and 400 Hz models. In addition, DARE has a series of external aircraft power monitors that continuously monitor the quality of electrical power in aircraft electrical systems, ground power equipment, auxiliary power units (APU?s), and other equipment for pre-determined over / under voltage conditions, over / under frequency conditions, loss of phase, improper phase sequence or phase rotation.
-
ViTec Co. Ltd
To develop an installation for contactless registration of beats of a rapidly rotating object. The installation should record the range and phase of the object beats simultaneously in several sections perpendicular to the axis of rotation. The results should be recorded in a file of the specified format.
-
TES Electrical Electronic Corp.
Communication with PC. 4000 continuity point data logger, 25 point manual data logger. True power/ apparent Power/ Power Fractor Measurement. True RMS. V,A,W cap Ind, phase indicator.