Showing results: 991 - 1005 of 1583 items found.
-
85131C -
Keysight Technologies
The Keysight 85131C is an 81 cm (32 in) long1 semi-rigid cable with a 3.5 mm female2-to-PSC-3.5 mm female connector. Cable frequency range is DC to 26.5 GHz with a return loss of 17 dB or better. Insertion loss is 0.43 * sqrt(f) + 0.3, where f is frequency in gigahertz, for the test port connector and 2.5 dB at maximum frequency for the device connector. Phase stability of the semi-rigid / flexible cables is specified with a 90-degree bend using a 4 to 3-inch radius. Stability1 of the 85131C is less than 0.06 dB, and phase is 0.16 * f + 0.5, where f is frequency in gigahertz.
-
VOT-53 -
Standard Electric Works Co., Ltd
● 2000-count digital display (LCD type). ● Test leads positioned at 19mm apart.● Interchangeable probe tip for 2mm and 4mm.● Polarity test ● Audible continuity test.● Auto sensing function for: voltage (AC/DC), Ω, diode.● Measurement function: ACV/DCV: 1000V Resistance: 2000Ω Frequency: 30Hz~1kHz ● Phase rotation test : ● Waterproof design, protection class: IP65.● Phase / Neutral identification.● Rubberized double-molded housing.● Flashlight function.● Safety standard : EN 61010-1 CAT III 1000V EN 61010-1 CAT IV 600V EN 61243-3 EN 61326-1
-
TGF4000 Series -
Aim-TTi
The TGF4000 series of function/arbitrary generators offers signal generation capability up to 240MHz on two identical full performance channels that can operate independently or in coupled or tracking modes. Precise channel to channel phase control with a resolution of 0.001° is provided. A wide range of built-in waveforms is included and custom arbitrary waveforms can be used at sample speeds up to 800MS/s and replay rates up to 80MHz. PC based arbitrary waveform generation and editing software is provided.
-
KH30937F -
Beijing KeHuan Century EMC Technology Co,.LTD
KH30937F log-periodic antenna (hereinafter referred to as KH30937F ) is a linearly polarized broadband receiving antenna with a working frequency of 30MHz~1GHz . KH30937F has excellent standing wave ratio characteristics, accurate feeding position, and the best phase relationship between each period on the base. The antenna gain is basically constant, thus ensuring that the antenna factor changes linearly and smoothly with the frequency, which is helpful for accurate difference calculation between each frequency point.
-
AFX Series -
Pacific Power Source, Inc.
The AFX Series is a family of high power, single, split and three phase, AC, DC and AC+DC output capable Power Sources. Available models range from 6 kVA to 90 kVA with available configurations to 150kVA. Using a modern user interface for ease of use, the AFX Series is cost effective and fully programmable for both basic frequency conversion and advanced AC power line or DC power disturbance test applications.
-
Pacific Millimeter Products
These waveguide bandwidth integrated coupler/mixers are designed to allow phase locking or signal monitoring of compact millimeter wave systems. RF inputs and outputs are on opposite sides of a thin wafer to obtain minimum insertion length. These devices use silicon Schottky barrier beam-lead diodes on a rugged stripline circuit. Nominal coupling value is 10 dB. For coupling values greater than 10 dB, non-directional coupler models are available (consult factory).
-
SS15000-PAL & SS15000-IL -
AOI Systems LTD
AOI Systems ScanSpection uses two basic algorithm groups to inspect component and soldering. The first algorithm checks the component related parameters at once, with these being entered to a Model training phase. The second algorithm group is for solder and lead inspection and offers the ability to use the optimum algorithm for the type of inspection to be carried out. In addition the solder inspection and lead inspection can be attached to a package type rather than component type to assist in programming.
-
National Technical Systems
Differential scanning calorimetry (DSC) measures Specific Heat Capacity, Heat of Transition, and the Temperature of Phase Changes and Melting Points. DSC measures the rate of heat flow, and compares differences between the heat flow rate of the test sample and known reference materials. As a sample undergoes a transition (melting, crystallization, etc.), heat is absorbed or emitted. This change in heat flow is then measured by the system and can be analyzed. The difference determines variations in material composition, crystallinity and oxidation.
-
Osborne Transformer Corp.
Osborne High Frequency Current Transformers operate at frequencies higher than 50/60 Hertz. Their purpose is to reduce high frequency system currents to lower values that are appropriate for instrumentation and/or protection circuits. They have been designed to meet specified current ratios, and burden impedance at a specified transformation error. One area of unique Osborne expertise is in designing for phase shift when high frequency current transformers are to be used for power measuring applications.
-
ACMAS Technologies Pvt. Ltd.
HALT and HASS chambers from WEIBER provide extreme temperature & vibration capabilities used during the product design and manufacturing cycles to compress the time normally required to identify design and process weaknesses. HALT techniques are important in uncovering many of the weak links inherent to the design and fabrication process of a new product. HASS techniques are incorporated during the production phase to find manufacturing process defects that could cause product failures in the field.
-
Teledyne Lincoln Microwave
Teledyne Lincoln Microwave design and manufacture RF amplifiers utilising the latest semiconductor technology. Our portfolio includes low noise amplifiers (LNA’s), power amplifiers and pre-amplifiers. These can incorporate linearization, filtering, phase and amplitude control functionality.
-
CP11B -
Calmet Smart Calibration Devices
Single phase, class 0.02 and 0.05 power quality calibrator up to 120A and 560VAC with programmable power quality parameters. It makes possible to make automatic test of electricity meters, measurement transducers, current transformers and protection relays.
-
T&R Test Equipment Ltd.
Our primary current injection test sets cover from 750A through to 6000A. Available in single phase, testing applications include testing and timing of under and over current relays, circuit breakers and CT ratio testing.
-
440A -
Novatech Instruments , Inc.
The 440A generates a sinewave is via an RS232 serial interface. The frequency is accurate to 1.5ppm and can be locked to an external frequency reference. The phase can also be programmed with 14-bit resolution. It includes a Line Voltage AC Adapter and a CD containing windows software.
-
M-310 -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*The unique U type CT enabled to measure the load current of single or three phase cable without separating the cable to the wires.*Leakage current measurements with least affection from the external magnetic field.*Wide current measurements.(AC0.01mA-300A)