Filter Results By:

Products

Applications

Manufacturers

Phase

the difference between two features of a waveform, measured in any of multiple manners (distance, time, angle, wavelength, etc.)

See Also: Phasing, Phase Standards, Phase Meters, Phase Angle, 3 Phase, Time


Showing results: 1471 - 1485 of 1583 items found.

  • Safety

    Chroma Systems Solutions, Inc.

    The purpose of safety testing medical electronic equipment is to be sure that a device is safe from electrical hazards to the patient and caregivers. There are a number of UL, European and Canadian standards that serve as the ruling body on how medical products will be tested, one in particular, IEC60601 (the International Electrical Safety Standard for medical electronic equipment) is experiencing “global harmonization,” meaning it has been accepted and implemented around the world. The IEC60601 standard is mainly intended for product development where safety considerations must be taken into account early in the design phase of a product, however much of it is applied to production line testing since it is the only way for a manufacturer to be sure they are shipping safe product.

  • Powermetrix Remote Manager®

    Powermetrix Systems

    Powermetrix extends the functionality of its industry leading line of handheld three phase analyzers with Powermetrix Remote Manager (PRM)®. PRM® enables wireless control of essential and various meter and meter site analysis and accuracy tests remotely. Real-time wireless transfer of testing and site data enables immediate reporting of test results. Using Bluetooth, PRM® enables seamless, remote wireless control of your Powermetrix analyzer with your secure Windows laptop or tablet, elevating your current testing and data collection capabilities. Add a higher level of safety operability with your PowerMaster® analyzer remotely with PRM®.

  • RF Ports Alignment Software

    Rohde & Schwarz GmbH & Co. KG

    With the R&S®RF Ports Alignment software together with the option R&S®SMW-K545, Rohde & Schwarz provides a standard and tailored solution for calibrating amplitude, time and phase of multi-channel SMW setups. The RF Port Alignment automatically collects the gathered correction data for the multi-channel setup using a connected vector network analyzer such as the R&S®ZNA or R&S®ZNB. Thanks to an intuitive graphical user interface the test engineer is guided through the calibration procedure step-by-step in a convenient way. With a calibrated multi-channel setup, tests of advanced systems in wireless communication or of radar receivers can be performed straightforward.

  • Electroacoustic Analysis System

    CRY6151B - CRYSOUND

    CRY6151B is a full-featured electroacoustic tester newly launched by CRY Sound. It is powerful and stable. It can measure the performance indicators of headphones (USB, Bluetooth, anti-noise), microphones (electret, MEMS, moving-coil type), headphone and microphone assemblies, receivers/headphone speakers, speakers/loudspeakers (common, Bluetooth), loudspeaker crossover devices, and other electroacoustic devices, such as sensitivity (SPL), impedance, distortion (THD), resonance frequency F0, left and right headphone balance, left and right headphone position, phase polarity, microphone current and voltage, SNR, microphone directivity, speaker's TS parameters, telephone receiving and sending loudness ratings, etc. Its test frequency range can be up to 20 Hz - 20 kHz.

  • NI-9237, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module

    779521-01 - NI

    50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The NI‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the NI‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools.

  • NI-9237, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module

    780264-01 - NI

    50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The NI‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the NI‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools.

  • NI-9237, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module

    780264-02 - NI

    50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The NI‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the NI‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools.

  • Gaussian Optics Lens Antennas

    SAG-1441544002-06-S1 - ERAVANT

    Gaussian optics lens antennas are offered with either a circular or rectangular waveguide interface. While Gaussian optics lens antennas with a rectangular waveguide interface can only support linear polarization, models with a circular waveguide interface can support various polarization types including horizontal, vertical, left-handed circular, and right-handed circular polarization for broader applications. Gaussian optics lens antennas are designed and constructed to offer high efficiency, low side lobes and a rugged mechanical configuration. A corrugated feed horn and dielectric lens allow these antennas to form well-defined Gaussian beams. Additionally, the dielectric lens provides phase error corrections and serves as a radome to protect from environmental conditions.

  • Dual Channel Bit Synchronizer for Rates up to 45 Mbps

    LS-45-DB - Lumistar Inc.

    The Lumistar LS-45-DB Dual Channel Bit Synchronizer Daughterboard provides optimal reconstruction of a serial PCM data stream that has been corrupted by noise, phase jitter, amplitude modulation, or base line variations. The all-digitaldesign assures a high performance, consistent product, with excellent reliability and long-term stability. Dual channel design can feed each channel of the LS-55-DD dual decom. The LS-45-DB also has a post D combiner that allows for optimal ratiocombining of the two input signals A unique Built-in-Test feature allows performance verification for the Bit Synchronizer to ensure the highest level of operation. Auto-test BIT is performed for a short duration on the application of power and tests more than 90% of the Bit Synchronizer components. This test verifies that power is properly applied, verifies that there are no internal bit errors, and performs other tests to ensure that the bit synchronizer is fully operational with status indication of results. Command-test BIT performs the same functions and can be initiated by the user at any time through the Lumistar software when used on Lumistar PC products. The user has the ability to generate internal pseudo-random patterns and calculate internal bit error rates with or without the injection of forced errors.Various status indicators are also available through the software. The Bit Synchronizer also contains a BER reader as well as frame sync pattern indicator.

  • Biconical Antennas

    Schwarzbeck Mess Elektronik

    Biconical Antennas have dipole like characteristics (e.g. circular directional pattern in the H-plane,"8"-shaped in the E-plane, fixed phase center, comparable gain), with an enormous wide bandwidth achieved by the double cone elements. One of the earliest and worldwide most popular biconical antenna designs is the BBA 9106 with balun VHA 9103 B. During the last years a growing need for expanded frequency ranges arised, which led to the design of biconical antennas reaching down to frequencies of 20 MHz and up to 18 GHz and above. A further increase of bandwidth was achieved with qualified 4:1 baluns, providing a typical gain increase of approx. 6 dB at the lower frequency range. The biconical elements can be mounted and dismounted within a few seconds providing perfect contact repeatability thanks to special clamping fixtures. A small wrench made of insulating material is supplied with the balun, it is tied to the balun head and thus always available whenever needed. Biconical antennas can be used for many applications, in which half-wave dipoles have been used traditionally. An enormous reduction of measurement time can be achieved, because the time consuming tuning of the antenna elements to the half wavelength is not needed, an important condition for sweeped broadband measurements. In typical dipole applications several discrete frequencies are measured, in contrast the biconical antenna allows continuous sweeps, where site anomalies are discovered much easier.

  • Solar Analyzers

    Meco Instruments Pvt. Ltd.,

    Max. solar system power (Pmax) search by Auto-scan: 1000V, 12A (12000W capability)The analyzer and the Remote Solar Detector is connected by Bluetooth wireless communication (Bluetooth 2.1 + EDR Class 1)The Remote Solar Detector is moisture-proofIntelligent test logic with no personnel attendance required in the field Solar system analyzer waits and tests the system until appropriate sunlight irradiance is detectedMax. voltage (Vpm) at Pmax, Max. current (Ipm) at Pmax Voltage at open circuit (Voc), Current at short circuit (Isc)Efficiency (%) calculation of solar systemTemperature measurement of solar panelsIrradiance measurement of sun lightSeries resistance (Rs) calculation of solar panelsWith data logging/open function, the I-V curves of solar system can be analysed / recorded for a period of time (e.g. 60 min.)Conversion of I-V curve under OPC to data under standard test condition (STC) based upon IEC standardProvide Operating Condition (OPC) and Standard Test Condition (STC) test reports for verification of solar panel performance (OK or NO OK)Users can set up the parameters of solar panelsUsers can set up the series number of solar panels. Parameters of many solar panels can be measured in one measurementThe Irradiances and Temperatures of solar panels can be continuously measured, monitored and recordedContinuously measure/monitor/record the DC power output of solar system and the AC power output of inverter (1 phase or balanced 3 phases)Calculate the efficiency of DC to AC power conversion and the efficiency of the max.output power

  • Near Field Probes 30 MHz up to 3 GHz

    RF1 set - Langer EMV-Technik GmbH

    The RF1 near field probe set consists of 4 passive near field probes for making measurements in the development phase of E-field and magnetic field in the ranges of 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF1 set allow for measurements close to the electronic assemblies, e.g. on single IC pins, conducting paths, components and their connectors in order to localize interference sources. Field orientation and field distribution on an electronic assembly can be detected through a trained special use of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.

  • SDC-A Series Multi-Octave Downconverter

    SDC-A - Saluki Technology Inc.

    SDC-A Series Multi-Octave Downconverter belongs to our microwave upconverter series that has a high performance and an octave overage by RF signal. Its frequency step is precise and accurate to 10Hz with a variety of IF and signal bandwidth choices.This series of converters is mainly used for electronic countermeasure system, radar system, and satellite communication system. Its excellent phase noise, clutter suppression, and in-band flatness data can provide a transparent RF transmission channel to all videos or data communications. All programming commands can be set through a local panel or through network remotely. SDC-A series microwave downconverter is available in 2U/ 4U sizes.Applications: T&M Systems / Satellite Communications / MIMO / Radar System

  • Fully Automatic Transformer Turns Ratio Tester

    DY100 - Neutronics Manufacturing Co.

    DY-100 is a new generation, fully automatic, transformer turns ratio tester designed for measuring ratio, ratio error of single and three phase transformers. The entire test is done automatically and quickly. Operator enters the test parameters and DY-100 tak es over; powers up the voltage, balances the bridge, takes the readings, and displays the results on the LCD screen. Prints testresults through its built-in printer. A key feature of the DY-100 is automatic measure transformer connection group. LV and HV windings are automatically isolated once the measurement is over. True portability is achieved by the lightweight (only 10 kg), single unit design housing the DY-100. The DY-100 is encased in an aluminum alloy cabinet.

  • Broadband Ridged Square Antennas

    ERAVANT

    A weather resistant, quad ridged, dual polarized antenna feed designed for outdoor application that operates from 0.7 GHz to 4 GHz. The antenna offers 8.0 dBi nominal gain and a typical half power beamwidth of 68 degrees on the E-plane and 98 degrees on the H-plane. The typical side lobe level is -10 dB and the port isolation is 20 dB at center frequency, respectively. The antenna supports linear polarized waveforms and can form the circular polarized waveform if the two ports are fed with 90 degree phase differenced and equal amplituded signals. The antenna has four 0.20” holes for mounting. The RF ports of the antenna are equipped with two female SMA (F) coaxial connectors.

Get Help