Showing results: 436 - 450 of 1871 items found.
-
MS 1723 -
Meltronics Systemtech
- Bus Interface:- 32 Bit PCI Bus with PMC Interface- Speed of operation up to 66MHz- Spartan-3AN FPGA and Arinc429 controller based design- 8 transmit and 8 receive independent channels- Driver interface for Windows2000/XP/VISTA and LINUX OS- Self Test future
-
MS 1802 -
Meltronics Systemtech
*Bus Interface - PCI Bus*Number of Channels 198*Compatibility - TTL*Power on state - Inputs (high-Z), pulled up or down (jumper selectable)*Handshaking - Input, Output, or bi-directional*Data transfers - Interrupts, programmed I/O*Driver interface for Windows2000/XP/VISTA and LINUX OS
-
H73000700 -
6TL Engineering
This module, named “6TL-MMI”, is designed to be the interface between an operator and a SYSTEM as well as being a metered power distribution unit (PDU) for it. The module is providing also safety controls, data bus interfaces, temperature control and timers. The 6TL-MMI is suitable for any ATE, and specially for those based on CAN bus controlled devices, because in addition to the above functionalities, this module is also providing galvanic isolation up to 1500V for the CAN bus. This isolation will block potential disturbance towards the DUT.
-
Excalibur Systems, Inc.
M4KH009 modules can operate as a Central Computer Complex (CCC) and/or up to sixteen Peripheral Units (PUs) simultaneously, or as a Bus Monitor. In addition, a Concurrent Bus Monitor enables concurrent monitoring of the bus during CCC and PU simulation. The module also supports error injection and detection, and all control parameters and data may be updated in real time. Note: The M4KH009 Module is a "double size" module, and occupies two vertically adjacent sockets in the EXC-4000 carrier Board.
-
M4KH009 -
Excalibur Systems, Inc.
H009 modules can operate as a Central Computer Complex (CCC) and/or up to 16 Peripheral Units (PUs) simultaneously, or as a Bus Monitor. In addition, a Concurrent Bus Monitor enables concurrent monitoring of the bus during CCC and PU simulation. The module also supports error injection and detection, and all control parameters and data may be updated in real time. Note: The M4KH009 Module is a "double size" module, and occupies two vertically adjacent sockets in the EXC-4000 carrier Board.
-
NI
LIN Interface Devices are bus interfaces for developing applications with the NI-XNET driver. The NI-XNET device-driven DMA engine couples the LIN bus to host memory to minimize message latency. You can import, edit, and use signals from LDF databases in integrated LIN databases. LIN Interface Devices work well for applications requiring real-time, high-speed manipulation of many LIN frames and signals, such as hardware-in-the-loop simulation, rapid control prototyping, bus monitoring, and automation control.
-
PXIe-XMC-IO -
ALPHI Technology Corporation
The carrier card interfaces an XMC mezzanine module to a PXI Express bus in a PXIe Chassis computer system. The PXIe bus adapter board allows a PXIe (PXIe bus master) to control and communicate with the hosted XMC module. It acts as an adapter to route signals between the system’s PXIe bus and the XMC module connector.
-
Euresys Inc.
Two CoaXPress CXP-12 connections: 2,500 MB/s camera bandwidthPCIe 3.0 (Gen 3) x4 bus: 3,300 MB/s bus bandwidthLow-profile card. Delivered with standard and low-profile brackets.Fan-cooled heatsinkFeature-rich set of 10 digital I/O linesExtensive camera control functionsMemento Event Logging Tool
-
Euresys Inc.
Four 250 MPixels/s JPEG encodersCompatible with 8-bit/pixel Bayer CFA camerasTwo streams per camera: JPEG stream and RGB preview streamFour CoaXPress CXP-12 connections: 5,000 MB/s camera bandwidthPCIe 3.0 (Gen 3) x8 bus: 6,700 MB/s bus bandwidth
-
MHS Elektronik
Our experience in the CAN bus area is evident in our Tiny CAN product range. Starting with our robust and inexpensive hardware adapters to the cross-platform Tiny-CAN-API to the monitoring tool Tiny-CAN-Monitor - both beginners and professionals will find a variety of solutions for the development of CAN bus systems.
-
Reach Technologies Inc.
Reach Technologies' CAN Logger is a high performance, high channel count, DSP enabled, automotive bus data logger. The CAN Logger is ideal for capturing all or specific bus traffic for vehicles under test. The CAN Logger is also perfect for real-time monitoring of specific signals.
-
9286-1015 -
Strobe Data Inc.
15" x 15" Backplane Adapter. Not to be used in production environment. Used with any I/O bus adapter during installation of Hawk system. Presents Nova/Eclipse bus signals on dual 50-pin connectors. Two 10 ft. (3 m) ribbon cables included.
-
783702-02 -
NI
LIN Transceiver Cable—The TRC-8546 is designed to provide flexibility in connecting a LIN bus to the NI-9860, PXIe-8510, and/or the native NI-XNET port on a cDAQ-9134 or cDAQ-9135 controller. You can connect the TRC-8546 to the port to support a LIN interface. The TRC-8546 is an isolated cable that includes the necessary transceiver for the bus type.
-
-