Showing results: 1561 - 1575 of 1877 items found.
-
40-761-008 -
Pickering Interfaces Ltd.
This terminated octal 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
778572-43 -
NI
6.6 GHz, 50 Ω, Solid-State, Dual 4x1 PXI RF Multiplexer Switch Module—The PXI‑2543 features high-performance solid-state relays that offer unique benefits such as unlimited relay life and fast switching time. Front-mounted SMA connectors provide easy connection to your RF devices, and the module features termination on every COM line and channel.
-
778572-44 -
NI
6.6 GHz, 50 Ω, Solid-State, 8x1 PXI RF Multiplexer Switch Module—The PXI‑2544 features high-performance solid-state relays that offer unique benefits such as unlimited relay life and fast switching time. Front-mounted SMA connectors provide easy connection to your RF devices, and the module features termination on every COM line and channel.
-
777697-01 -
NI
48‐Channel, 1-, 2-, or 4-Wire, Electromechanical PXI Multiplexer Switch Module—The PXI‑2503 is a PXI switch module that you can configure as a multiplexer or matrix switch by using different terminal block accessories. It uses electromechanical relays with low thermal offset for accurate measurements and offers a 1,024‐step scan list for deterministic scanning.
-
778572-96 -
NI
26.5 GHz, 50 Ω, Dual 6x1 (SP6T) PXI RF Multiplexer Switch Module—The PXI‑2596 is an RF signal multiplexer switch with dual 6x1 multiplexer banks in the same module. It is ideal for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules. You can use the PXI‑2596 onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.
-
778572-97 -
NI
26.5 GHz, 50 Ω, 6x1 (SP6T) Terminated PXI RF Multiplexer Switch Module—The PXI‑2597 is ideal for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules. The internal termination of the PXI‑2597 helps prevent high-power reflections that arise from open channels on the module. You can use the PXI‑2597 onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.
-
34921A -
Keysight Technologies
The Keysight 34921A module for the 34980A Multifunction Switch/Measure Unit is the most versatile multiplexer for general purpose scanning. It has low thermal offset characteristics and a built-in thermocouple reference on the terminal block, making it ideal for temperature measurements directly to the internal DMM. The dense, multi-function switching with 100 channel/second scan rates addresses a broad spectrum of data acquisition applications.
-
34922A -
Keysight Technologies
The Keysight 34922A module for the 34980A Multifunction Switch/Measure Unit offers high density multiplexer switching in a compact size. It combines dense, multi-function switching with 100 channel/second scan rates to address a broad spectrum of data acquisition applications.
-
778572-95 -
NI
5 GHz, 50 Ω, 4x1 PXI RF Multiplexer Switch Module—The PXI‑2595 is ideal for applications that require the routing of high-frequency signals inside automated test equipment (ATE) systems because it can switch signals with very low insertion loss. The module also features excellent insertion loss, voltage standing wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use the onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.
-
778572-55 -
NI
2.5 GHz, 75 Ω, Terminated 4x1 PXI RF Multiplexer Switch Module—The PXI‑2555 is an RF signal multiplexer switch module. The internal termination of the PXI‑2555, which helps prevent high-power reflections that arise from open channels on the module, makes it ideal for use in video RF applications where such reflections can damage the source. The module also features excellent insertion loss, voltage standing wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use the onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.
-
778572-30 -
NI
128-Channel, 1-, 2-, or 4-Wire PXI Multiplexer Switch Module—The PXI‑2530B is a high-density, multiconfiguration reed-relay switch. With four multiplexer and three matrix configurations, the PXI‑2530B is an excellent solution for complex or high‑channel‑count systems. Multiplexer configurations include 128x1 (1‑wire), 64x1 (2‑wire), 32x1 (4‑wire), or eight banks of 16x1 (1‑wire). Matrix configurations include 4x32 (1‑wire), 8x16 (1‑wire), or 4x16 (2‑wire). You can implement these configurations by selecting the appropriate terminal block.
-
40-571A-303 -
Pickering Interfaces Ltd.
The 40-571A-303 is a 12-channel, 12-pole 3 Amp Power Multiplexer and is part of our BRIC family. The 40-571A range is designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing.
-
40-571-303 -
Pickering Interfaces Ltd.
The 40-571 is a Power Multiplexer designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is possible for most configurations, see switching specifications for restrictions). It is ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. It is available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts.
-
40-571-205 -
Pickering Interfaces Ltd.
The 40-571 is a Power Multiplexer designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is possible for most configurations, see switching specifications for restrictions). It is ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. It is available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts.
-
40-571-106 -
Pickering Interfaces Ltd.
The 40-571 is a Power Multiplexer designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is possible for most configurations, see switching specifications for restrictions). It is ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. It is available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts.