  • 6U CompactPCI 2-slot SSL 33MHz VIO 5V BW 32-Bit

    80952-002-6610 - ELMA Electronic, Inc.

    6U CompactPCI Backplane 2-slot, PICMG 2.0 R3.0, system slot left, supports full hot swap function according to PICMG 2.1 R2.0 hot-swap specification, clock frequency 33MHz, V(I/O) +5V, bus width 32-bit, power input connection with Fastons connectors

  • 6U CompactPCI 3-slot SSL 33MHz VIO 5V BW 64-Bit

    80952-003-6600 - ELMA Electronic, Inc.

    6U CompactPCI Backplane 3-slot, PICMG 2.0 R3.0, system slot left, supports full hot swap function according to PICMG 2.1 R2.0 hot-swap specification, clock frequency 33MHz, V(I/O) +5V, bus width 64-bit, power input connection with Fastons connectors

  • 6U CompactPCI 3-slot SSL 33MHz VIO 5V BW 32-Bit

    80952-003-6610 - ELMA Electronic, Inc.

    6U CompactPCI Backplane 3-slot, PICMG 2.0 R3.0, system slot left, supports full hot swap function according to PICMG 2.1 R2.0 hot-swap specification, clock frequency 33MHz, V(I/O) +5V, bus width 32-bit, power input connection with Fastons connectors

  • Power Monitor, AC-Powered

    PMA/PQA - North Atlantic Industries

    NAI's PMA and PQA Power Monitors are used to monitor voltage, frequency, and phase characteristics of single- or three-phase power lines. This allows normal operation of system loads when the power line characteristics are within predetermined limits. These power monitors are ideally suited for rugged defense and industrial applications.

  • 200KHz / 10000Freq.Point LCR Meter

    MCH-2816A - MCH Instruments Co.,Ltd.

    It has high test frequency of 300kHz and 0.01Hz stepping arbitrary programming, and it has 10mV-2V signal level, all making it meet the precision test requirements of production line quality control, in-coming inspection and lab. Its HANDLER, RS232c interfaces are used for the component automatic sorting system, which provides the conditions for computer telecommunication and test recording. Flexible frequency-response analysis:Due to non-ideal inductor, capacitor and resistor, in order to precisely evaluate the characteristics of one component in one frequency band, MCH2816 could use its signal generation ability with 10mHz resolution to correctly analyze frequency response of the component parameters in any frequency band. In particular, it can do the precise measuring of the resonant impedance of the low-frequency ceramic resonant devices which has wide impedance range.

  • FM Tokenless Transmitter & Receiver

    MS 1522 - Meltronics Systemtech

    Transmitter and Receiver units are designed to work at 24V DC voltage (nominal) with variation between 19.2 V to 28.8V. The system is designed to work with carrier frequency 1800/2700 Hz and modulated frequency 65Hz/85Hz. For 1800Hz Carrier Frequency RED border is used in Front Panel and for 2700Hz Carrier Frequency BLUE border is used in Front Panel. Maximum power consumed by transmitter and receiver are 1.2W and 8W, respectively. Sense level for receiver is less than –19 dBm and No sense level for receiver is more than –22 dBm with 1mw (0 dBm) transmitter power. The equipment is designed to work satisfactorily with temperature variation from 0°C to 55°C with relative humidity of 95% at 35°C. Suitable test points are provided in the back of the equipment to monitor the necessary parameters.

  • Phase Noise Analyzers

    AnaPico Ltd

    The APPH is a fully contained signal source analyzer with a frequency range of 1 MHz to 7, 26 and 40 GHz. It offers an indispensable set of measurement functions for evaluating signal sources ranging from VHF to microwave frequencies but also active and passive non self oscillating devices like amplifiers, or frequency dividers.

  • Spectrum Analyzer Modular AFM AXIe

    Holding Informtest

    The software and hardware complex "Modular Spectrum Analyzer AFM AXIe" for the analysis of RF signals with a frequency of up to 10 GHz is intended for use in automated testing programs, research in the frequency domain of periodic signals in the RF and microwave ranges, as well as for analyzing the parameters of signals with analog modulation (AM, World Cup, FM).

  • Lock-in Amplifier

    HF2LI - Zurich Instruments AG

    The Zurich Instruments HF2LI (high-frequency, 2 inputs) is a digital lock-in amplifier covering the frequency range between DC and 50 MHz. It features 2 physical input channels so that it can replace 2 devices in many measurement setups. The 128-bit digital signal processing delivers superior precision thus boosting both the noise performance and the dynamic reserve. With these unprecedented capabilities, the HF2LI brings lock-in amplification to a new level and enables new applications in a frequency range that was previously tied to analog instrumentation. The computer is connected by a high-speed USB interface, which allows data acquisition at high rates. The HF2LI is delivered with a fully featured graphical user interface and a choice of programming interfaces that greatly add to the usability of the instrument.

  • PCI Dual Channel Multi-Band Down Converter

    LS-27-D - Lumistar Inc.

    The Lumistar LS-27-D3 TwoChannel Quad Band PCI Down Converter product is a 3rd generation high-density, high performance down converter designed using the sameadvanced technology as in the industry leading LS-25 PCIReceiver. The down-converter converts one or two independent channels of up to four RF frequency bands down to a 70 MHz IF output. The LS-27-D3 is typically used in conjunction with theLumistar LS-35 Series Digital IF Receiver/Combiner to provide one or two independent telemetry receivers, or a dual diversity combining receiver, with up to two multi-mode demodulators and bit synchronizers in a two-slot PCI interface. The number of channels and frequency band designations can be specified at the time of order. Please see the data sheet for the LS-35-R Digital IF Receiver/Combiner for more information.

  • PD Test Systems

    Shanghai Himalayal Co.

    1. Number of channels: 2/4 electric signal interfaces & 1 EXT interface 2. Sampling frequency: maximum 200MGa/s 3. Sampling precision: 12bit 4. Range: 0.1mV~20V 5. Range switch: 1mV, 2mV, 5mV, 10mV, 20mV, 50mV, 100mV, 200mV, 500mV, 1V, 2V, 5V 6. Frequency band range: 1Hz-60MHz 7. Range non-linear error: 5% 8. Range of capacitance for test object: 6pF~250µF 9. Power source mode: internal lithium cell / AC 220V 10. Display: 6.5 inches TFT LCD 11. Resolution: 640×480 12. PV: 4GB 13. Hard disk: 32G stiff disk used for storing the test data

  • 6 Channel Function Generator / Flow Simulator

    DP-cPCI-2601 - Data Patterns Pvt. Ltd.

    DP-cPCI-2601 is a 6 Channel 2MS/s Waveform Generator with high frequency performance, versatility and compact size in an economical cPCI bus format. Signal output in the range of 10 mHz to 5 KHz with 14 bit vertical resolution makes this single slot, 6U-sized cPCI card a powerful solution to meet most demanding test stimulus.DP-cPCI-2601 uses Direct Digital Synthesis (DDS) technique to generate stable and accurate output waveforms down to 0.01 Hz resolution. DP-cPCI-2601 offers Sine, Square, Ramp, Triangle, Pulse as built-in wave shapes and user defined arbitrary waveform.DP-cPCI-2601 can frequency sweep any of its function outputs. User can sweep upwards using linear sweeps.

  • Chroma LCR Meters

    Chroma Systems Solutions, Inc.

    Some of the key features to look for in an LCR meter (also known as an impedance meter) are: accuracy, test frequency, measured parameters, test voltage and test current. Additionally, an easy to understand display of test results and the ability to access and use these results has become increasingly important. Component testing often requires much more than simply a resistance, capacitance or inductance value at a given test frequency and stimulus voltage. An LCR meter or impedance meter must have the flexibility to provide multi-parameters over wide frequency and voltage ranges.

  • Charged Plate Monitor

    Model 280A - SIMCO-ION, Technology Group

    Simco-Ion’s Model 280A incorporates enhanced circuitry that enables it to more accurately measure the performance of high frequency AC ionizers, as well as pulsed DC ionizers and steady-state DC ionizers. The Model 280A can be used as a portable CPM and is capable for of up to 6 hours of operation on the internal battery before recharge.

  • Current Probe For Non-Intrusive Measurement Of AC, DC, And Waveform Currents

    CP 305 - GMC-I-PROSyS

    The CP 305 current probe has been designed for use with oscilloscopes respectively for accurate, non-intrusive measurement of AC, DC and complex waveform currents.Using advanced Hall Effect technology the CP 305 can measure currents accurately up to 450A peak over the frequency range of DC to 20 kHz.