Showing results: 541 - 555 of 4207 items found.
-
3671 -
Saluki Technology Inc.
3671 series network analyzer provides frequency response, single-port, response isolation, enhanced response, full-dual port, electronic calibration etc. Offer various display formats, such as logarithmic amplitude, linear amplitude, phase, group delay, Smith chart and polar coordinates. 3671 series can accurately measure the amplitude frequency characteristics and phase frequency characteristics and group delay characteristics of microwave network.
-
KM 2239 B / KM 2240 -
Kusam Electrical Industries Limited
Stroboscope is a flash - frequency velocity measuring device. It is a rotation speed measuring device that makes use of persistence of vision (when the light source synchronize with the rotation speed of an object at a pre-set flashing frequency, a relatively static phenomenon called visual persistence will occur).In the course of observation of an object that rotates or moves at a high speed ,adjust the flashing frequency of the device to synchronize it with rotation or movement speed of the object. .
-
DS Instruments
Measure the strength of radio frequency signals in dBm or watts.
-
RTS03 -
KEYCOM Corp
RTS03 measures relative permittivity (dielectric constant), dielectric loss tangent in the frequency range between 5GHz and 26.5GHz based on a correlation between measurement frequency and transmission attenuation as the microwave passes through the flat plane sample.
-
AtlanTecRF
Incorporating fundamental frequency phase locked oscillators and double balanced mixers, the translators block convert frequencies from uplink to either downlink or L-Band and from L-Band to downlink for instantaneous monitoring of frequency, power levels and modulation.
-
F900 -
ASL
The Model F900 is designed specifically for resistance thermometry to provide you with the best possible accuracy. The 25Hz or 75Hz operating frequency provides fast, continuous measurement with high immunity to thermal emfs and supply frequency noise sources.
-
RFATT AXIe-0 -
Holding Informtest
*Dual channel AXIe attenuator with frequency range from 9 kHz to 10 GHz.*The module is designed to work as part of information measuring systems as a normalizer of radio frequency signals (power control: signal amplification or attenuation).
-
HMMC-3028 -
Keysight Technologies
The HMMC-3028 is a DC - 12 GHz divide by eight prescaler designed for use in high frequency communications, microwave instrumentation, and EW radar systems where low phase-noise PLL control circuitry or broadband frequency translation is required.
-
HMMC-3022 -
Keysight Technologies
The HMMC-3022 is a DC - 12 GHz divide by two prescaler designed for use in high frequency communications, microwave instrumentation, and EW radar systems where low phase-noise PLL control circuitry or broadband frequency translation is required.
-
R42XXE -
Elmika
The R42XXE Vector Network Analyzers are designed for measuring of S-parameters, VSWR and impedance of waveguide networks in the full frequency ranges of standard waveguides between 33 and 170 GHz. Frequency accuracy is ±0.2%. The measurement range of reflection factor modulus is from 0 to 1. The measurement range of reflection factor phase is from 0 to ±180° for 0.1< |Гx|<1 with accuracy ±7.5 o in 18-75 GHz frequency range and ±9.6° in 75-170 GHz frequency range. The measurement range of transmission factor phase is from 0 to ±180 o with accuracy ±(5+0.1 |Ax|) o for Ax >-50 dB in frequency range to 75 GHz, for Ax >-30 dB - to 170 GHz. Data can be displayed in the rectangular, Smith or polar diagrams. VNA requires Personal Computer with USB interface.
-
VM-810 -
Vivax-Metrotech Corp
Using the correct frequency makes a world of difference when locating buried utilities. The depth of the utility, size, material, and amount of congestion (proximity of other utilities) all need to be taken into consideration for the correct frequency selection. Large diameter, direct buried pipes with bell housing ends that use insulators and rubber gaskets, such as water or gas require a higher frequency while smaller diameter, well-grounded direct buried or long distance in conduits work, better with a lower frequency. The VM-810 operates at 83.1kHz which is ideal for water and gas utilities which generally are larger pipes with bell housings and gaskets. The VM-810’s higher frequency is also good for locating ungrounded small diameter drop wires and inducing signals through the soil, onto services when direct connecting is not an option.
-
85131C -
Keysight Technologies
The Keysight 85131C is an 81 cm (32 in) long1 semi-rigid cable with a 3.5 mm female2-to-PSC-3.5 mm female connector. Cable frequency range is DC to 26.5 GHz with a return loss of 17 dB or better. Insertion loss is 0.43 * sqrt(f) + 0.3, where f is frequency in gigahertz, for the test port connector and 2.5 dB at maximum frequency for the device connector. Phase stability of the semi-rigid / flexible cables is specified with a 90-degree bend using a 4 to 3-inch radius. Stability1 of the 85131C is less than 0.06 dB, and phase is 0.16 * f + 0.5, where f is frequency in gigahertz.
-
FG-274 -
Texio Technology Corp.
* Output Waveforms of Sine, Square, Triangle and Pulse.* The design of DDS and FPGA technology provide high quality waveforms.* High frequency stability and accuracy: 20ppm.* Low Distortion at -55dBc.* Wide output frequency range: 4MHz* Maximum frequency resolution of full range: 100mHz.* TTL/CMOS output* Variable DC offset control* Variable Duty ratio control* Output overload protection* Store/Recall function
-
VCH-1008 -
VREMYA-CH JS Company
The VCH-1008 Passive Hydrogen Maser is a compact hydrogen maser with excellent frequency stability and utilises state-of-the-art technology. Full digital processing of the modulation and servo loop signals makes it ideal for high accuracy applications. An internal GPS/GLONASS option is available and provides automatic output signal frequency calibration.Key applications:- National Time Keeping Service- Space tracking and navigation- Verification of frequency signals - Scientific research
-
MGC-1 -
Macintyre Electronic Design Associa
The MGC-1 is a low noise high sensitivity single axis AC magnetic field sensor used for the measurement of audio frequency fields. Because of its innovative design, the MGC-1 amplitude response is insensitive to the frequency of the field over its 5 Hz to 10 kHz frequency band. Accuracy at 1 kHz is ±1%, and the amplitude response stays within 2 dB peak-to-peak over the bandwidth.