Filter Results By:
Products
Applications
Manufacturers
-
product
Comb Generator, 10 MHz to 50 GHz
U9391F
The Keysight Technologies, Inc. U9391F comb generators were developed to provide precision phase calibration, for non-linear measurements using the PNA-X nonlinear vector network analyser (NVNA), referenced to the National Institute of Standards and Technology (NIST) standard. Additionally, the comb generators can be used to calibrate PNA and PNA-X network analyzers for phase and delay measurements of frequency converters without requiring reference or calibration mixers.
-
product
10 MHz – 18 GHz USB Power Sensor
U2000H
U2000H USB Power Sensor measures average power over the frequency range 10 MHz to 18 GHz and power range -50 dBm to +30 dBm.
-
product
Waveguide Power Sensor
Q8486D
Excellent SWR for reducing mismatch uncertainty50 MHz calibration port Accurate calibration and traceability to US National Institute of Standards and Technology (NIST) millimeter-wave sensor calibration Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters, plus the E1416A VXI and discontinued 70100A and 43X power meter Accurate average power measurements over -70 to -20 dBm Frequency range 33 GHz to 50 GHz Diode power sensing element
-
product
InfiniiMax Probe, 5 GHz
1132B
Provides extremely low input capacitance, flat frequency response, and patented resistor probe tip technology.
-
product
Frequency Converter Test Solution Up To 50 GHz
N5245BP
The N5245BP provides the N5245B 50 GHz PNA-X network analyzer, application software and accessories for frequency converter test up to 50 GHz. This bundle product
-
product
Remote High Performance Receiver
E1709A
The measurement signal frequency changes as the stage velocity changes. The Keysight E1709A ensures minimal phase processing errors due to frequency changes. The receiver also provides immunity to errors induced by changes in measurement signal power that occur due to small pitch, roll and yaw movements during stage motion. These features help provide the most accurate measurements under system motion.
-
product
Semi-Rigid Cable, 3.5 Mm (Test Port) To 3.5 Mm
85131C
The Keysight 85131C is an 81 cm (32 in) long1 semi-rigid cable with a 3.5 mm female2-to-PSC-3.5 mm female connector. Cable frequency range is DC to 26.5 GHz with a return loss of 17 dB or better. Insertion loss is 0.43 * sqrt(f) + 0.3, where f is frequency in gigahertz, for the test port connector and 2.5 dB at maximum frequency for the device connector. Phase stability of the semi-rigid / flexible cables is specified with a 90-degree bend using a 4 to 3-inch radius. Stability1 of the 85131C is less than 0.06 dB, and phase is 0.16 * f + 0.5, where f is frequency in gigahertz.
-
product
SNS Series Noise Source 10 MHz to 18 GHz (ENR 6 dB)
N4000A
The SNS series N4000A noise source is designed for accurately measuring devices with low noise figure, with a frequency range of 10 MHz to 18 GHz and nominal ENR 6 dB.
-
product
DC - 12 GHz Packaged High Efficiency Divide by 8 Prescaler
HMMC-3128-BLK
TheHMMC-3128-BLK is a packaged DC - 12 GHz divide by eight prescaler designed for use in high frequency communications, microwave instrumentation, and EW radar systems where low phase-noise PLL control circuitry or broadband frequency translation is required.
-
product
Cable Assembly, Type-N (m) to Type-N (m), DC to 6.0 GHz
11500B
The Keysight 11500B is a 58 cm (23 in) type-N male to type-N male cable assembly with a frequency range of DC to 6.0 GHz.
-
product
Custom Systems
With our custom VNA your ATE works as one software system running on a single computer. We can customize the analyzer module to fit in your system, provide extra frequency range coverage as compared to our standard VNA models should you need it in your specific application or characterize the expected performance outside the frequency limits of our standard VNAs.
-
product
ATE Connecting Solutions
C.C.P. Contact Probes Co., LTD.
Customized pogo towers with high frequency capability.
-
product
PXIe Microwave Signal Generator, 1 MHz to 44 GHz
M9383A
Modular test solution for design validation that can be efficiently leveraged into manufacturing Flexibility to solve your immediate test needs, but upgradable for what comes next – whether that’s upgrading for frequency coverage, or a rapid shift to high volume production.Pre-5G signal confidence you need with 1% EVM @ 28 GHz, 800 MHz bandwidth
-
product
Frequency Ranges
1398A
The useable frequency range is from 5 Hz to more than 10 times higher than that listed in the table below, e.g. T2.5-1 volt and T5-2 volt can be used beyond 10 MHz.
-
product
RS232 I2C Adapter LowPower
*I2C frequency adjustable up to 100kHz*Maximum power consumption <5mA*Interrupt input for external events*Simple software interface (ASCII commands)
-
product
PXIe Frequency Reference: 10 MHz And 100 MHz
M9300A
The M9300A PXIe frequency reference is a PXIe-compatible, compact, modular instrument that can be used with the Keysight M9301A synthesizer, M9310A source output, and M9311A modulator to create the world’s fastest vector signal generator, the M9381A. Create a CW source, the M9380A, by combining the M9300A with the M9301A and M9310A or use it as the 10-MHz or 100-MHz reference with other PXI solutions. Control the instrument through a soft front panel and programmatic interfaces tuned to your application development environment of choice.
-
product
Line Input Test
Measure the dB level and frequency of the iAudioInterface2 line input or line output (also works with any dock input audio source).
-
product
TERAHERTZ ROOM TEMPERATURE DETECTORS FROM 37.5 GHZ To 996 THz
Insight Product Company offers Golay cells that detect electro-magnetic waves at terahertz frequency ranges from 0.0375 to 996 THz.
-
product
High Frequency RF and Microwave USB Programmable Signal Generators
LMS Series
The Lab Brick LMS series of high frequency RF and microwave USB-compatible, synthesized signal generators cover a frequency range from 0.5 MHz - 20 GHz with low noise, fast 100-microsecond switching time, and fine 100 Hz frequency resolution. They require no additional DC supply voltage and offer advanced features such as phase-continuous linear-frequency sweeping, internal/external 10 MHz reference, and optional pulse modulation. GUI software can track and control several connected signal generators, simplifying multiple-signal test setups. Each device stores settings in internal memory, allowing it to power up in a specific instrument state.
-
product
Static Frequency Converter Systems with Built-in Isolation System
FC3X Series
- VFI independent output as per IEC62040- User friendly controls and indications- Compact design with inbuilt transformer- Rugged and field proven for Industrial and Defence application- Ultra light weight- Higher efficiency of operation means significantly lower running costs- State of the art IGBT based PWM technology, to increase crest factor tolerance & dynamic stability- Continuously delivers full output power at ambient as high as 45ºC- Can feed upto 400% rated current for half cycle- Very high MTBF
-
product
RF Detectors
RF detectors from Fairview Microwave are available with N Type or SMA connector series inputs and BNC or SMA connectors for outputs. Fairview RF detectors are zero bias Schottky diode and have negative video out. These zero bias Schottky diode detectors for RF have a minimum frequency between 10 MHz and 2 GHz and maximum frequency range between 2 GHz and 26.5 GHz.
-
product
PXIe Vector Modulator
M9316A
The M9316A PXIe Vector Modulator is a 3-slot module with integrated wideband IQ modulator and arbitrary waveform generator (AWG) designed to work with the M9383A PXIe Microwave Signal Generator. When ordered with M9383A, it can support 1MHz to 20 GHz frequency coverage, up to 160 MHz RF bandwidth, and up to 1 Giga-sample of AWG playback memory. (See M9383A PXIe Microwave Signal Generator options.
-
product
PIN Photodiode
PIN photodiode is a kind of photo detector, it can convert optical signals into electrical signals.This technology was invented in the latest of 1950's. There are three regions in this type of diode. There is a p-region an intrinsic region and an n-region. The p-region and n-region are comparatively heavily doped than the p-region and n-region of usual p-n diodes. The width of the intrinsic region should be larger than the space charge width of a normal p-n junction. The PIN photo diode operates with an applied reverse bias voltage and when the reverse bias is applied, the space charge region must cover the intrinsic region completely. Electron hole pairs are generated in the space charge region by photon absorption. The switching speed of frequency response of photo diode is inversely proportional to the life time. The switching speed can be enhanced by a small minority carrier lifetime. For the photo detector applications where the speed of response is important, the depletion region width should be made as large as possible for small minority carrier lifetime as a result the switch speed also increases.
-
product
Laser Diode
A laser diode, also known as an injection laser or diode laser, is a semiconductor device that produces coherent radiation (in which the waves are all at the same frequency and phase) in the visible or infrared (IR) spectrum when current passes through it.
-
product
General Purpose Pressure Sensors For High Frequency
PCB® Series 113B dynamic pressure sensors set the standard for extremely fast, micro-second response with a wide amplitude and frequency range. These characteristics allow them to excel in high-frequency applications, where minimum sensor diameter is required.
-
product
Accelerometers
356A02
Sensitivity (10 %)10 mV/g1.02 mV/(m/s) Measurement Range:500 g pk4900 m/s pk Frequency Range: (5 %)1 to 5000 Hz1 to 5000 Hz Frequency Range: (10 %)0.5 to 6000 Hz0.5 to 6000 Hz Resonant Frequency:25 kHz 25 kHz Broadband Resolution (1)0.0005 grms 0.005 m/s rms Non-Linearity: (400 g, 3920 m/s)1 % 1 % Non-Linearity (500 g, 4900 m/s)2 % 2 % Transverse Sensitivity:5 % 5 %.
-
product
Accelerometers
352C33
Sensitivity (10 %) 100 mV/g10.2 mV/(m/s) Measurement Range:50 g pk 490 m/s pk Frequency Range (5 %)0.5 to 10000 Hz0.5 to 10000 Hz Frequency Range (10 %)0.3 to 15000 Hz0.3 to 15000 Hz Resonant Frequency:50 kHz50 kHz Broadband Resolution(1)0.00015 grms0.0015 m/s rmsNon-Linearity:1 %1 % Transverse Sensitivity:5 %5 %.
-
product
Ground Isolated ICP® Pressure Sensors For High Frequency
PCB® Series 102B is a ground isolated version of the Series 113B. These sensors have all of the same features and benefits of the 113B Series, plus the added benefit of isolation, which helps prevent ground loop problems. This series can accommodate an optional ablative coating (Prefix: CA) to protect the diaphragm from thermal shock in flash-temperature applications.
-
product
Miniature Piezoelectric Accelerometers
Structured with highly sensitive piezoceramic sensing elements, miniature Ceramic Shear ICP® Accelerometers have an excellent signal-to-noise ratio, high measurement resolution, and are ideal for conducting low-level vibration measurements. Due to their inherent higher sensitivity, a ceramic ICP® accelerometer can be assembled with a smaller mass than comparable quartz units, resulting in a sensor that is lighter in weight, has a higher frequency response, and has a lower noise floor. To further reduce the mass of the sensors, all ceramic shear accelerometers are housed in either tough, lightweight, laser-welded, hermetically sealed, titanium or aluminum housings. By minimizing the mass of the sensor, mass loading effects are reduced, which maximizes the accuracy of the data obtained.
-
product
Piezoresistive MEMS Shock Accelerometers
Piezoresistive shock accelerometers, manufactured by MEMS technology, have low power consumption while still providing +/- 200 mV full scale output. They afford a wider operating temperature range when compared to mechanically isolated ICP® accelerometers. Their frequency response ranges from DC (0 Hz) to 20 kHz. To lessen the severity of response when their resonant frequency is excited, they incorporate squeeze film damping, achieving values of 0.02 to 0.06 of critical.