Showing results: 3661 - 3675 of 8202 items found.
-
40-788-021-TE -
Pickering Interfaces Ltd.
The 40-788-021-TE (PXI) and 42-788-021-TE (PXIe) are single failsafe SP8T 18 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-927-101 -
Pickering Interfaces Ltd.
This 21-slot PXIe Chassis provides one PXIe system slot and 20 hybrid-compatible slots for application flexibility. The chassis utilizes three PCI segments with a dedicated PCIe-to-PCI bridge module for the hybrid slots. The PXI-specific high-accuracy clocks and trigger signals are generated and controlled by an independent clock module attached to the rear of the backplane.
-
40-788-041-TE -
Pickering Interfaces Ltd.
The 40-788-041-TE (PXI) and 42-788-041-TE (PXIe) are single failsafe SP8T 26.5 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-131-TE -
Pickering Interfaces Ltd.
The 40-788-131-TE (PXI) and 42-788-131-TE (PXIe) are single failsafe SP10T 22 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-121-TE -
Pickering Interfaces Ltd.
The 40-788-121-TE (PXI) and 42-788-121-TE (PXIe) are single failsafe SP10T 18 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-041-TE -
Pickering Interfaces Ltd.
The 40-788-041-TE (PXI) and 42-788-041-TE (PXIe) are single failsafe SP8T 26.5 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-121-TE -
Pickering Interfaces Ltd.
The 40-788-121-TE (PXI) and 42-788-121-TE (PXIe) are single failsafe SP10T 18 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-131-TE -
Pickering Interfaces Ltd.
The 40-788-131-TE (PXI) and 42-788-131-TE (PXIe) are single failsafe SP10T 22 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-221-TE -
Pickering Interfaces Ltd.
The 40-788-221-TE (PXI) and 42-788-221-TE (PXIe) are single failsafe SP12T 18 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-221-TE -
Pickering Interfaces Ltd.
The 40-788-221-TE (PXI) and 42-788-221-TE (PXIe) are single failsafe SP12T 18 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-022-TE -
Pickering Interfaces Ltd.
The 40-788-022-TE (PXI) and 42-788-022-TE (PXIe) are dual failsafe SP8T 18 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-022-TE -
Pickering Interfaces Ltd.
The 40-788-022-TE (PXI) and 42-788-022-TE (PXIe) are dual failsafe SP8T 18 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-122-TE -
Pickering Interfaces Ltd.
The 40-788-122-TE (PXI) and 42-788-122-TE (PXIe) are dual failsafe SP10T 18 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-122-TE -
Pickering Interfaces Ltd.
The 40-788-122-TE (PXI) and 42-788-122-TE (PXIe) are dual failsafe SP10T 18 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-042-TE -
Pickering Interfaces Ltd.
The 40-788-042-TE (PXI) and 42-788-042-TE (PXIe) are dual failsafe SP8T 26.5 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.