Showing results: 3976 - 3990 of 8202 items found.
-
42-785C-561-T -
Pickering Interfaces Ltd.
The 40-785C-561-T (PXI) and 42-785C-561-T (PXIe) are single failsafe SP6T 3 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
42-785C-441-T -
Pickering Interfaces Ltd.
The 40-785C-441-T (PXI) and 42-785C-441-T (PXIe) are single failsafe SP4T 40 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
42-785C-422-T -
Pickering Interfaces Ltd.
The 40-785C-422-T (PXI) and 42-785C-422-T (PXIe) are dual failsafe SP4T 18 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
42-785C-431-T -
Pickering Interfaces Ltd.
The 40-785C-431-T (PXI) and 42-785C-431-T (PXIe) are single failsafe SP4T 26.5 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
42-785C-421-T -
Pickering Interfaces Ltd.
The 40-785C-421-T (PXI) and 42-785C-421-T (PXIe) are single failsafe SP4T 18 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
42-785C-521-T -
Pickering Interfaces Ltd.
The 40-785C-521-T (PXI) and 42-785C-521-T (PXIe) are single failsafe SP6T 18 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
42-785C-531-T -
Pickering Interfaces Ltd.
The 40-785C-531-T (PXI) and 42-785C-531-T (PXIe) are single failsafe SP6T 26.5 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
42-785C-522-T -
Pickering Interfaces Ltd.
The 40-785C-522-T (PXI) and 42-785C-522-T (PXIe) are dual failsafe SP6T 18 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
42-785C-432-T -
Pickering Interfaces Ltd.
The 40-785C-432-T (PXI) and 42-785C-432-T (PXIe) are dual failsafe SP4T 26.5 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
42-785C-442-T -
Pickering Interfaces Ltd.
The 40-785C-442-T (PXI) and 42-785C-442-T (PXIe) are dual failsafe SP4T 40 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
42-785C-532-T -
Pickering Interfaces Ltd.
The 40-785C-532-T (PXI) and 42-785C-532-T (PXIe) are dual failsafe SP6T 26.5 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
42-785C-542-T -
Pickering Interfaces Ltd.
The 40-785C-542-T (PXI) and 42-785C-542-T (PXIe) are dual failsafe SP6T 40 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
AFL
AFL provides cost-effective fiber microscopes with integrated protective infrared filters that minimize the risk of viewing a live fiber. AFL also provides video inspection products with no direct optical path between fiber and the users eye. These products employ a video signal path (like a camcorder viewfinder) and convert the optical image to a safe, high resolution video image.
-
42-785C-451-T -
Pickering Interfaces Ltd.
The 40-785C-451-T (PXI) and 42-785C-451-T (PXIe) are single failsafe SP4T 50 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
N2752A -
Keysight Technologies
The N2752A InfiniiMode differential probe is a new generation of low-cost differential active probes compatible with Keysight InfiniiVision and Infiniium oscilloscopes’ AutoProbe interface. It comes with new operation modes and convenient measurements of differential, single-ended, and common mode signals with a single probe tip, without reconnecting the probe to change the connection. The N2752A probe’s InfiniiMode provides the following modes of operation.