Showing results: 6781 - 6795 of 8202 items found.
-
DAB/DAB+ -
TestTree
Combined with a Network Monitoring System or not, the EdgeProbe Advanced provides a powerful broadcast network alert & diagnosis tool allowing Digital Radio network operators to monitor global trends and anticipate potential failures.EdgeProbe Advanced is able to monitor DAB/DAB+ signals at transmitter outputs as well as at modulator input, through its RF inputs (up to 4 in 1RU), and at Head-End/distribution links, through its ETI and IP (EDI) inputs.
-
782385-11 -
NI
The TB-2645B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 16x16 or 1-wire dual 16x16 matrix. You can directly connect the TB-2645B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2645B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
782385-12 -
NI
The TB-2645B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 16x16 or 1-wire dual 16x16 matrix. You can directly connect the TB-2645B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2645B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
782385-10 -
NI
The TB-2644B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 8x32 or 1-wire dual 8x32 matrix. You can directly connect the TB-2644B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2644B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
782385-07 -
NI
The TB-2643B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 4x64 or 1-wire dual 4x64 matrix. You can directly connect the TB-2643B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2643B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
782385-08 -
NI
The TB-2643B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 4x64 or 1-wire dual 4x64 matrix. You can directly connect the TB-2643B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2643B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
782385-09 -
NI
The TB-2644B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 8x32 or 1-wire dual 8x32 matrix. You can directly connect the TB-2644B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2644B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
N2797A -
Keysight Technologies
Testing devices over extreme temperature ranges is quite common these days. The N2797A single-ended active probe is the industry’s first low-cost high input impedance active probe with rugged probe tips for environmental chamber testing of ICs and devices. It gives the ability to probe signals at drastic temperature swings ranging from –40 °C to +85 °C. The probe provides 1.5 GHz of bandwidth and a 2 m long cable.
-
Safran - Navigation & Timing
Now more than ever, it’s critical to protect military systems from the threat of GNSSGlobal navigation satellite system (GNSS): A general term describing any satellite constellation that provides positioning, navigation, and timing (PNT) services on a global or regional basis. See also GPSGlobal Positioning System is a navigation satellite system. See also signal jamming and spoofing by using anti-jamming GPS and spoofing detection solutions.
-
N9935C -
Keysight Technologies
Capture elusive signals with up to 120 MHz gap-free, real-time bandwidth.Make accurate spectrum analyzer measurements (± 0.3 dB) without warmup.Perform over-the-air measurements for 5G NR and LTE.Use GPS/GNSS for geolocation and timestamping.Carry one lightweight unit at 3.4 kg (7.4 lb).What's included:Base model: spectrum analyzer (SA)AC/DC adapterLocalized power cordRechargeable Li-ion batterySoft carrying case with backpack and shoulder straps
-
TE6100 -
TEAM SOLUTIONS, INC.
The TE6100 is the first 100 MS/SEC measuring instrument that consists of a Digital Storage Oscilloscope, Spectrum Analyzer, Transient recorder and Voltmeter. This new PXI based, compact measuring instrument, can solve almost every measurement problem. Analyzing signals is done with an 8-bit resolution and a maximum sampling speed of 100 MHz. The input ranges 0.1 Volt full scale to 80 Volt full scale. The record length is 32K/64K samples.
-
60-802-415 -
Pickering Interfaces Ltd.
The 60-802-415 is a 4-channel, 15-bank RF multiplexer suitable for switching 50Ω signals up to 40GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
60-802-316 -
Pickering Interfaces Ltd.
The 60-802-316 is a 4-channel, 16-bank RF multiplexer suitable for switching 50Ω signals up to 26.5GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
60-802-309 -
Pickering Interfaces Ltd.
The 60-802-309 is a 4-channel, 9-bank RF multiplexer suitable for switching 50Ω signals up to 26.5GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
60-802-209 -
Pickering Interfaces Ltd.
The 60-802-209 is a 4-channel, 9-bank RF multiplexer suitable for switching 50Ω signals up to 18GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.