Filter Results By:

Products

Applications

Manufacturers

Signal

detectable impulse of electromagnetic radiation or quantum state superposed.

See Also: Signal Sources, Signal Processing, Signal Integrity, Signal Proccessing, Signal Analyzers, Signaling, Signal Conditioning, Signal Generators, Signal Meters, Signal Conditioners, Fidelity, Hunting


Showing results: 7711 - 7725 of 8202 items found.

  • NI-9403, 5 V/TTL, 32 Bidirectional Channels, 7 µs C Series Digital Module

    780179-01 - NI

    5 V/TTL, 32 Bidirectional Channels, 7 µs C Series Digital Module - The NI‑9403 is a configurable digital I/O interface for input or output with shift‑on‑the‑fly capabilities. Each channel features transient isolation between the I/O channels and the backplane. With reconfigurable I/O (RIO) technology (CompactRIO only), you can use the LabVIEW FPGA Module to program the NI‑9403 for applications such as custom, high-speed counter/timers; digital communication protocols; and pulse generation. In a CompactDAQ chassis, you can use the NI‑9403 only as a static (software-timed) digital I/O module. You cannot use these modules to route timing or triggering signals.

  • PCIe-7841, Virtex-5 LX30 FPGA, 200 kS/s Multifunction Reconfigurable I/O Device

    781100-01 - NI

    Virtex-5 LX30 FPGA, 200 kS/s Multifunction Reconfigurable I/O Device - The PCIe‑7841 features a user-programmable FPGA for high-performance onboard processing and direct control over I/O signals for complete flexibility of system timing and synchronization. You can customize these devices with the LabVIEW FPGA Module to develop applications requiring precise timing and control such as hardware‑in‑the‑loop testing, custom protocol communication, sensor simulation, and high-speed control. The PCIe‑7841 features a dedicated A/D converter per channel for independent timing and triggering. This design offers specialized functionality such as multirate sampling and individual channel triggering, which are outside the capabilities of typical DAQ hardware.

  • Enhanced Time Domain Analysis With TDR

    S96011B - Keysight Technologies

    Use S96011B to perform enhanced time domain analysis for high-speed data applications. Includes all functionality of the S96010B (TDR/TDT mode). In addition, the S96011B enables more detailed measurements and evaluations, such as eye diagram / mask modes, without adding PLTS software. Jitter and emphasis / equalization capabilities enable simulation of real-world signals and environment. The S96011B covers up to 53 GHz bandwidth. Full calibration is available and the automatic deskew ensures easy removal of fixture and probe effects. To get the best accuracy, use mechanical calibration kits or ECal with DC option (i.e. N469xD or N4433D with Option 0DC).

  • Digital Wideband Transceiver Analysis

    S94610B - Keysight Technologies

    Digital Wideband Transceiver Analysis is an add-on software to Device Measurement eXpert (DMX) that adds cross-domain stimulus response measurements for digital/RF mixed-signal device characterization. Included Waveform Creator helps define digital IQ test stimulus waveforms that are used in the RF signal generators for receiver tests or downloaded to the digital-to-analog converters for transmitter tests. The DUT control is customizable to accommodate various data converters and transceiver types by defining device operation settings, transmit/receive switching, reading and writing digital IQ waveform from and to DUTs. Acquired RF or digital data is processed in the VNA’s applications for faster, accurate measurements and analysis.

  • Spectrum Analysis, Up To 13.5 GHz

    S930901B - Keysight Technologies

    The S930901B spectrum analysis adds high-performance microwave spectrum analysis to the PNA family up to 13.5 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Simultaneous spectrum measurements can be done using up to five test and reference receivers. This multi-channel SA can be used with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.

  • NI-9403, 5 V/TTL, 32 Bidirectional Channels, 7 µs C Series Digital Module

    779787-01 - NI

    5 V/TTL, 32 Bidirectional Channels, 7 µs C Series Digital Module - The NI‑9403 is a configurable digital I/O interface for input or output with shift‑on‑the‑fly capabilities. Each channel features transient isolation between the I/O channels and the backplane. With reconfigurable I/O (RIO) technology (CompactRIO only), you can use the LabVIEW FPGA Module to program the NI‑9403 for applications such as custom, high-speed counter/timers; digital communication protocols; and pulse generation. In a CompactDAQ chassis, you can use the NI‑9403 only as a static (software-timed) digital I/O module. You cannot use these modules to route timing or triggering signals.

  • Spectrum Analysis, Up To 70 GHz

    S930907B - Keysight Technologies

    The S930907B spectrum analysis (SA) adds high-performance microwave spectrum analysis to the N522xB/N524xB PNA family up to 70 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Simultaneous spectrum measurements can be done using up to five test and reference receivers. This multi-channel SA can be used with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.

  • Enhanced Time-Domain Analysis With TDR

    S95011B - Keysight Technologies

    This application enables the analyzer to perform enhanced time domain analysis for high-speed data applications. All functionality of the S95010B are included (TDR/TDT mode). In addition, the S95011B enables more detailed measurements and evaluations, such as eye-diagram / mask modes, without adding PLTS software. Jitter and emphasis / equalization capabilities enable simulation of real-world signals and environment. The S95011B covers up to 53 GHz bandwidth. Full calibration is available and the automatic deskew ensures easy removal of fixture and probe effects. To get the best accuracy, mechanical calibration kits or ECal with DC option (i.e., N469xD or N4433D with Option 0DC) are recommended.

  • Spectrum Analysis, Up To 26.5 GHz

    S930902B - Keysight Technologies

    The S930902B spectrum analysis adds high-performance microwave spectrum analysis to the PNA family up to 26.5 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Simultaneous spectrum measurements can be done using up to five test and reference receivers. This multi-channel SA can be used with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.

  • Real-time Spectrum Analyzers

    SSA3000X-R - SIGLENT Technologies

    The SIGLENT SSA3000X-R real-time spectrum analyzers are powerful and flexible tools for complex RF signal monitor and analysis. With a capability of 40 MHz analysis bandwidth and 7.2 µs 100% POI, the analyzer can provide multi-dimensions data displays, advanced triggering, and RF data capturing, to solve modern RF spectrum challenges, like hopping frequency, conflict channel, spectrum interference, etc. They also provide standard tracking generator for network analysis, optional wideband digital modulation analysis, and EMI pre-compliance test. Applications include broadcast monitoring/evaluation, cellular site, IoT, WiFi, Bluetooth surveying, research and development, education, production, and maintenance.

  • Compact Receiver Module

    MixAMC-I - Virginia Diodes, Inc.

    Virginia Diodes'' standard Spectrum Analyzer Extension Modules (SAXs) provide high performance broadband down-conversion and frequency extension of microwave specturm analyzers into the THz range. VDI now offers integrated MixAMC modules that provide industry leading performance in a compact package. These integrated MixAMC modules are used to down-convert millimeter-wave / THz signals only. Spectrum Analyzer Extension mode is not currently available for the MixAMC-I products. Integrated MixAMC modules utilize a low frequency LO input (<20 GHz) and have a seprate IF output port. Integrated MixAMC modules configured for high IF bandwidth may be available upon request.

  • Spectrum Analysis For E5081A Up To 20 GHz

    S960904B - Keysight Technologies

    The Keysight S960904 spectrum analyzer (SA) software application adds high-performance spectrum analysis to the E5081A ENA-X up to 20 GHz. With fast-stepped FFT sweeps resulting from optimized data processing, the SA software application provides quick spurious searches over broad frequency ranges. The application enables simultaneous spectrum measurements using test and reference receivers. The multichannel SA pairs with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application uses source-power and receiver-response calibration and fixture de-embedding, providing highly accurate in-fixture and on-wafer spectrum measurements.

  • NI-9326, 6-Channel, 150 V, 128 kHz C Series Frequency Input Module

    786999-02 - NI

    6-Channel, 150 V, 128 kHz C Series Frequency Input Module - The NI-9326 is a channel-to-channel isolated frequency input module for CompactDAQ and CompactRIO systems. This module includes six differential input channels with a 0 Vrms to 150 Vrms input range. The NI-9326 also features configurable thresholds for connection to a variety of variable reluctance sensors, single channel encoders, and hall-effect sensors. You can use the included embedded counters to perform frequency measurements or edge-counting for tracking total counts on a periodic signal. Additionally, the NI-9326 supports configurable Butterworth filters to help you perform low-noise frequency measurements.

  • NI-9205, cDAQ-9171, and cRIO-9940 USB Voltage Measurement Bundle

    865683-01 - NI

    NI-9205, cDAQ-9171, and cRIO-9940 USB Voltage Measurement Bundle - The USB Voltage Measurement Bundle with NI-9205, cDAQ-9171, and cRIO-9940 includes the NI-9205 C Series Voltage Input Module and the cDAQ-9171 CompactDAQ Chassis for voltage measurements. This bundle also includes the cRIO-9940 Backshell for strain relief and operator protection from high-voltage signals. The included NI-9205 features a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. Additionally, the NI-9205 provides up to 60 V of overvoltage protection between input channels and common, and it is rated for 1,000 Vrms transient overvoltage protection.

  • NI-9326, 6-Channel, 150 V, 128 kHz C Series Frequency Input Module

    786999-01 - NI

    6-Channel, 150 V, 128 kHz C Series Frequency Input Module - The NI-9326 is a channel-to-channel isolated frequency input module for CompactDAQ and CompactRIO systems. This module includes six differential input channels with a 0 Vrms to 150 Vrms input range. The NI-9326 also features configurable thresholds for connection to a variety of variable reluctance sensors, single channel encoders, and hall-effect sensors. You can use the included embedded counters to perform frequency measurements or edge-counting for tracking total counts on a periodic signal. Additionally, the NI-9326 supports configurable Butterworth filters to help you perform low-noise frequency measurements.

Get Help