Showing results: 826 - 840 of 8202 items found.
-
MODEL LCA-9PC -
Transducer Techniques, Inc
The LCA-9PC Module provides low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-9PC comes with DB9 male and female connectors, which require soldering to user-furnished mating female or male wire connectors. On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film otentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.
-
MODEL LCA-RTC -
Transducer Techniques, Inc
The LCA-RTC Module provide low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-RTC comes with removable screw-clamp terminal connectors, which accept wires without soldering.On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film potentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.
-
VISQUE® -
Vieworks Co., Ltd.
Patented algorithms for kinetic analysis of molecular diffusion phenomenon- Tmax, Tarrival, Imax, Iarrival, Trising, 1st Peak, FluAngio, DyAngio, etc.Kinetics visualization with feature mapsTime-series kinetics graphs
-
MSG1M / MSG2M / MSG3M -
Aplab Limited
- Wide frequency range- Sine, triangle, square, ramp, pulse, TTL (Sync) & DC outputs- Low distortion high resolution on low frequency output attenuation up to 80dB- Variable DC offset control- Four digit digital display with frequency indication in Hz, KHz, MHz/Amplitude display
-
SG-10 -
GME Technology
Model SG-10 architecture is based on the latest advances in DDS technology. Microprocessor control delivers clean and accurate DC to 10MHz waveforms with frequency accuracy of 0.02% and 0.1 Hz frequency resolution.
-
ScanTAP IsoPod -
Corelis, Inc.
The Corelis ScanTAP IsoPod™ is an add-on accessory that provides a galvanic isolation barrier between the target system and the boundary-scan (JTAG) controller hardware. While the Corelis boundary-scan controllers are highly robust and reliable, the complete electrical isolation helps prevent damage to the controller from harsh electrical environments where over-voltage and over-current can damage components.This Corelis ScanTAP IsoPod was designed to add an additional layer of protection with minimal cost and effort. Open the box and plug it in; everything just works.
-
ATS800R -
Rohde & Schwarz GmbH & Co. KG
The R&S®ATS800R CATR based 5G NR mmWave test chamber provides a very compact over the air (OTA) testing environment for testing 5G FR2 antennas, modules and devices in R&D. The R&S®ATS800R has a very small footprint and wide frequency range, and offers maximum functionality and test coverage in a small space. The flexible setup options and range of extensions make the R&S®ATS800R a solid and future-proof environment for your FR2 testing needs.
-
EIB 5000 series -
Heidenhain Corp.
*Reduced cabling*Overload protection for direct drive motors*Faster response behavior for excessive temperatures*Greater cost-effectiveness
-
Pickering Interfaces Ltd.
We have the expertise and ability to turn your high-level requirements for a microwave switching subsystem into the fully integrated solution that you need. You provide us with your unique configuration and specification, and our engineers will work closely with you to provide a well-defined, fully integrated and supportable end product that will satisfy your microwave testing needs.
-
M9393A -
Keysight Technologies
9 kHz to 8.4 GHz, 14 GHz, 18 GHz, or 27 GHz Frequency extension to 50 GHz (minimum frequency of 3.6 GHz) with Option FRX40 MHz (standard), 100 MHz, or 160 MHz analysis bandwidth, and optional wideband IF output with Option WB1Up to 4 time-synchronous channels
-
-
783127-01 -
NI
PXIe, 250 kHz to 20 GHz, PXI RF Analog Signal Generator - The PXIe-5654 features a combination of exceptional phase noise and frequency tuning time. These features address applications such as blocker test/receiver desensitization, high-performance intermodulation distortion measurements, and various electronic warfare applications. The PXIe-5654 is designed to meet the challenging requirements of RFIC characterization, satellite test, and radar applications. Some PXIe-5654 options include a PXIe-5696 Amplitude Extender Module. The PXIe-5696 supports a frequency range of 250 kHz to 20 GHz and an extended amplitude range up to 27 dBm.
-
784777-02 -
NI
PXIe, 250 kHz to 20 GHz, PXI RF Analog Signal Generator - The PXIe-5654 features a combination of exceptional phase noise and frequency tuning time. These features address applications such as blocker test/receiver desensitization, high-performance intermodulation distortion measurements, and various electronic warfare applications. The PXIe-5654 is designed to meet the challenging requirements of RFIC characterization, satellite test, and radar applications. Some PXIe-5654 options include a PXIe-5696 Amplitude Extender Module. The PXIe-5696 supports a frequency range of 250 kHz to 20 GHz and an extended amplitude range up to 27 dBm.
-
784777-01 -
NI
PXIe, 250 kHz to 20 GHz, PXI RF Analog Signal Generator - The PXIe-5654 features a combination of exceptional phase noise and frequency tuning time. These features address applications such as blocker test/receiver desensitization, high-performance intermodulation distortion measurements, and various electronic warfare applications. The PXIe-5654 is designed to meet the challenging requirements of RFIC characterization, satellite test, and radar applications. Some PXIe-5654 options include a PXIe-5696 Amplitude Extender Module. The PXIe-5696 supports a frequency range of 250 kHz to 20 GHz and an extended amplitude range up to 27 dBm.
-
784776-02 -
NI
PXIe, 250 kHz to 20 GHz, PXI RF Analog Signal Generator - The PXIe-5654 features a combination of exceptional phase noise and frequency tuning time. These features address applications such as blocker test/receiver desensitization, high-performance intermodulation distortion measurements, and various electronic warfare applications. The PXIe-5654 is designed to meet the challenging requirements of RFIC characterization, satellite test, and radar applications. Some PXIe-5654 options include a PXIe-5696 Amplitude Extender Module. The PXIe-5696 supports a frequency range of 250 kHz to 20 GHz and an extended amplitude range up to 27 dBm.