Showing results: 3106 - 3120 of 6646 items found.
-
Sensors -
Foerster Instruments, Incorporated
We offer a comprehensive range of standard and customised sensors, probes and coils for component testing. If the wide selection of standard sensors does not optimally solve your testing task, we offer you an individual new development specially adapted to your testing task. Thanks to our many years of experience, you receive reliable sensor technology for reproducible test results.
-
CX-I.5S -
Shenzhen Chuangxin Instruments Co., Ltd.
Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.
-
CX-8000 -
Shenzhen Chuangxin Instruments Co., Ltd.
Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.
-
Arden Photonics LTD
Arden’s MPX Modal Explorer makes measurement of Encircled Flux easy, and accurate, and it complies with international standards. But if you are measuring laser-based transmission light sources for multimode systems you may need to use a test jumper assembly and fiber shaker in order to avoid “speckle”. Industry standards (for example IEEE 802.3aq and FOTP– 203) call for the use of a mechanical fiber shaker.
-
ProDAQ 3080 -
Bustec Ltd.
The ProDAQ 3080 VXIbus Gigabit Ethernet slot-0 interface provides access to VXIbus instruments through a standard Gigabit Ethernet interface using the VXI-11 protocol. It is designed to function as a bridge between the established, time-tested, proven base of VXIbus instruments and the Ethernet, allowing users to build any size of test and measurement system simply by connecting the instruments via standard LAN to a computer.
-
MPX-SR3 -
Arden Photonics LTD
Arden’s MPX Modal Explorer makes measurement of Encircled Flux easy, and accurate, and it complies with international standards. But if you are measuring laser-based transmission light sources for multimode systems you may need to use a test jumper assembly and fiber shaker in order to avoid “speckle”. Industry standards (for example IEEE 802.3aq and FOTP– 203) call for the use of a mechanical fiber shaker.
-
ACMAS Technologies Pvt. Ltd.
For testing various size Walk in Solar Panel Test Chamber WIEBER designs and manufactures Walk in Solar Photovoltaic Testing Chamber. The test are to be performed according to various standards of ASTM, IEC, UC etc. Solar panels need to pass environmental tests as per IEC and other standards requirements to prove their long term performance and resistance to temperature and humidity extremes.
-
Kikusui Electronics Corp.
a high performance electrical safety analyzer that complies to a wide range of universal standards. Hipot, Insulation Resistance, Ground Bond, Leakage Current (touch current and protective conductor current) and partial discharge can all be tested. A total of 6 models are available for standard compliance tests in a wide variety of applications including R&D, quality assurance manufacturing lines and laboratory tests.
-
MTB-3200 -
The Eastern Specialty Company
Run standard meter accuracy tests and complex meter accuracy tests under widely varying loading conditions with TESCO’s Meter Test Board (MTB-3200). TESCO’s Three Phase Meter Test Board (MTB-3200) is an innovative meter accuracy test system offering unsurpassed functionality and ease of use. All of the features needed to test meters today and tomorrow are standard.
-
U9391M -
Keysight Technologies
U9391M comb generators were developed to provide precision phase calibration, for non-linear measurements using the PNA-X nonlinear vector network analyser (NVNA), referenced to the National Institute of Standards and Technology (NIST) standard. Additionally, the comb generators can be used to calibrate PNA and PNA-X network analyzers for phase and delay measurements of frequency converters without requiring reference or calibration mixers.
-
SL100 -
TEAM SOLUTIONS, INC.
The SL100 uses a standard 16450 UART with baud rate settings that makes it capable of communicating with a Chrysler CCD Vehicle bus. The SL100 uses a protected interface driver chip, as prescribed by the bus specification, to connect with vehicle peripherals in a robust and highly noise immune way. The card automatically configures to become another COM port by using the built-in O.S. drivers that are tried and tested and are optimized to work in the Windows environment.
-
Testwell CTC++ -
Verifysoft Technology GmbH
Testwell CTC++ is the leading Code Coverage Tool for measuring Code Coverage on host and all embedded targets (even very small ones). The tool is compliant to Safety Standards. Hundreds of companies all over the world use Testwell CTC++ with great success. Testwell CTC++ is the first choice for companies which have to achieve and to proof high code coverage in aerospace, automotive, transportation, healthcare and other industries.
-
NovoTest
Concrete Cover Meter NOVOTEST Rebar Detector (rebar locator) is designed in accordance to EN 12504-4, ASTM C597-02, ISO 1920-7:2004, IS13311, CECS 21 standards and is intended for operational monitoring of reinforced (searching rebars inside building structures) concrete products and structures for process control in the factories and building sites, surveys buildings and structures. The device measures the protective layer of concrete by magnetic method.
-
STMicroelectronics
Darlington devices are high-voltage, high-current switch arrays containing multiple open-collector Darlington pairs or multiple Darlington transistors with common emitters, and integral suppression diodes for inductive loads. The nominal current rating of each output is 500 mA for the 7- and 8-output devices and up to 1.5 A for quad-output devices. The inputs are pinned opposite the outputs to simplify the application board layout. These devices interface standard logic families.
-
FTM-1 – UKAS -
Rhopoint Metrology Ltd
Baty dial thickness gauges are direct reading instruments for quick and accuratemeasurement of rod, strip or sheet material, such as paper. All standard instruments aresupplied with 10mm (0.39″) diameter at contacts. The well balanced frame andhandgrip make these thickness gauges very easy to use for the measurement of sheet easy to use for the measurement of sheet materials.The lifting lever and springloaded spindle ensures controlled contact pressure on the sample.