Showing results: 2911 - 2925 of 6660 items found.
-
ST-8850 -
Standard Instruments Co., LTD.
This digital meter is ideal for general sound level measurements. The device features analog AC/DC outputs for connecting to an analyzer or recorder. Coming with a wide range of 30dB to 130dB, this sound level meter is great for measuring noise in factories and checking acoustics in auditoriums. 1.5dB accuracy. Meets IEC651 type 2 standard. Max. hold and data-hold functions. Built-in calibration check.
-
HD3000L -
Hildebrand Prüf- und Meßtechnik GmbH
Type 1: Slim Probe 1, foot DIA. 8 mm for hard to reach areas or irregular shapes.Type 2: Chisel shaped (angled foot) for hard to reach or narrow areas.Type 3: Slim Probe 2, DIA. 5.0 mm. A thinner foot for reaching hard to get places or irregular shapes. Custom designed durometers conform to the Hildebrand Company standard.
-
ForTest Italia Srl
The T9731 is specifically designed for measure the adequate air flow rate in complete adherence to the standard EN 14683 for surgical masks testing.Full scale from 10 mbar to 10,000 cc/minFlow measurement accuracy : 1% RDG + 0.1% FSFlow measurement resolution : 1 cc/minDirect pressure accuracy : 0,5% RDG + 3 DGTDirect pressure resolution : 0.001 mbar (0.1 Pa)
-
AMETEK Sensors, Test & Calibration
Our temperature indicators, combined with STS sensors, are fully traceable reference thermometers used to verify temperature in any type of calibrator, liquid bath, or dry-blocks. Combine with both “smart” and standard temperature sensors to directly measure critical temperatures in process environments and custody transfers. The DTI series includes one portable bench top indicator and one light-weight, hand-held indicator.
-
TRD System -
Spherea Technology Ltd.
The TRD System helps users develop and document the strategy and structure of test programs using TRD format screens, flowchart generation tools and documentation formats, all in accordance with the most popular military standard format ( MIL-STD-1519) or with unique custom formats. It also has the ability to automatically generate an ATLAS test program from the TRD information provided by the user.
-
SERIES
80 -
Test Connections Inc.
MAXIMUM CURRENT: 6 amps continuousat working travel, non-inductiveRESISTANCE: At 35 mA test current,35 mOHMS meanMaterials and FinishesPLUNGER: Heat treated berylliumcopper, 24 Kt gold plated over nickelBARREL: Nickel silver with 24 Kt goldplated ID and OD over nickelSPRING: (Standard) Beryllium copper,silver plated. (-1) Stainless steel,silver plated
-
HUBDISK-1 -
U. S. Digital
US Digital offers a wide variety of standard hub / disk assemblies (optical encoder disks attached to an aluminum hub) to aid with mounting on a shaft. Encoder disks may also be ordered as a stand alone item (see the Disks page). These rotary encoder disks are made from mylar polyester film. This material allows for a wide temperature range and is virtually unbreakable.
-
HUBDISK-2 -
U. S. Digital
US Digital offers a wide variety of standard hub / disk assemblies (optical encoder disks attached to an aluminum hub) to aid with mounting on a shaft. Encoder disks may also be ordered as a stand alone item (see the Disks page). These rotary encoder disks are made from mylar polyester film. This material allows for a wide temperature range and is virtually unbreakable.
-
TCR Series -
Innovative Technical Systems
Precision radar cross section measurements demand precision calibration targets like the TCR Series trihedral corner reflectors. Manufactured to close mechanical tolerances, TRC trihedrals provide reliable and repeatable calibration standards over a wide frequency range through 100 GHz. Surface flatness and perpendicularity are maintained to 1/100 of a wavelength to insure close agreement with theoretical performance.
-
8510-CS -
Wuxi Tianmu Instrument Technology Co., Ltd.
Determination of elements: carbon and sulfur combined measurementAnalytical principle: tube furnace combustion infrared absorption method detectionAnalysis range: carbon: 0.0010%-10.000% ( expandable to 99.9999%) Carbon: 0.0005%-0.500% ( expandable to 99.9999%)Analysis error: carbon: in line with GB/T223.69-1997 standard sulfur: in line with GB/T223.68-1997 standardAnalysis time: 20-100 seconds adjustableElectronic balance: not quantitatively weighed, weighing range: 210g/0.001g
-
MC6-Ex -
Beamex Oy Ab
The MC6-Ex is an intrinsically safe field calibrator and communicator. It is ATEX and IECEx certified and can be used in all hazardous zones / divisions. The MC6-Ex includes a field communicator for HART, FOUNDATION Fieldbus and Profibus protocols. Each calibrator is delivered with a traceable, accredited calibration certificate as a standard. t is a documenting, multifunction calibrator and communicator that offers calibration capabilities for pressure, temperature and various electrical signals.
-
Instron
Instron® High-Temperature Extensometers are perfect for testing advanced composites, metals, polymers and other materials at elevated temperatures. This series incorporates a capacitive sensor that does not require any cooling. The extensometers come standard with a sensor conditioner unit providing a 0-10 V output with exceptionally low noise. These extensometers can be attached to round and flat specimens to perform tensile, compression, and cyclic tests.
-
Ironwood Electronics
The male pin adapter consists of standard high temperature FR4 with pressed in terminal pins and threaded inserts for mounting the socket. The top side of adapter has gold plated pads to receive socket interconnect and the bottom side has 0.006″ to 0.018″ diameter pin tails. These pins can be soldered to the plated thru holes in the target board. Then socket can be mounted to the threaded insert.
-
Applied Image, Inc.
The Sinusoidal Array SINE M-7 has an image size of 22mm x 30mm which makes it small enough to fit into a standard 35mm projection frame. The gray scale is contained in the outer rows. It is made on 35mm perforated film.The TM-G variations are produced on a wider film (without perforations) and cemented between glass. They are available at each modulation (-35, -60, -80).
-
OPTIMASS 1400 -
Datum Electronics, Ltd.
Optimass 1400 Flowmeter is a high-accuracy Coriolis mass flowmeter for general ship fuel applications in the marine industry, including fuel mass, density and volume flow measurement (±0.15% of MV) in the harshest conditions on ships.The OPTIMASS 1400 is a cost-effective twin straight tube Coriolis mass flowmeter for a wide range of standard applications with gases and liquids (up to 170,000 kg/h or 6,235 lb/min).