Showing results: 121 - 135 of 439 items found.
-
1153 AI -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-Null key.● Test Auto-Stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Accept 8 rechargeable batteries or Alkaline of normal.● BS 16 edition.
-
1154 TMF -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-Null key.● Test Auto-Stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Accept 8 rechargeable batteries or Alkaline of normal.● BS 16 edition.
-
1152 MF -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-Null key.● Test Auto-Stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Accept 8 rechargeable batteries or Alkaline of normal.● BS 16 edition.
-
1151 IN -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at Switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-null key.● Test Auto-stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Accept 8 rechargeable batteries or Alkaline of normal.● BS 16 edition.
-
1155 TMF -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-Null key.● Test Auto-Stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Accept 8 rechargeable batteries or Alkaline of normal.● BS 16 edition.
-
PeakTech Prüf- und Messtechnik GmbH
This cable detector works acoustically and offers a quick and inexpensive solution to find voltage-free lines in the house installation, to test telephone lines, to identify individual cables / wires or to carry out a continuity test.
-
Cimbian UK Ltd.
Cable testing service available from Cimbian includes:Helping you with the test specificationBuilding the test interface, where necessaryCreating the test programBarcodingTest reportsSimple continuity testingMeasurement/verification of resistances and diodes (traceable to national standards)Hi-Pot testing to 1500VDC / 1000VAC
-
125 -
TEGAM Inc.
If you need a continuity function or harmonics are a problem then the Voltman TRMS is for you. Non sinusoidal waveforms from variable speed motors cause problems for most meters but the Voltman TRMS meter is specifically designed to produce accurate and dependable readings of distorted waveforms. When there is no voltage present the unit automatically tests for continuity, ground faults or shorts.
-
TX 01 -
Chauvin Arnoux Metrix
Communicating 5-1 V Telecom Insulation and Continuity Tester2 GΩ, Test voltage: 5-1 VContinuity, Voltage, Frequency, CapacitanceDistance = f(C)Storage, Communication
-
TRMS 6000 -
AstroAI Corp.
WIDE RANGE of tests for Voltage, Current, Resistance, Continuity, Capacitance, Frequency; Tests Diodes Transistors, TemperaturePROFESSIONAL LEVEL features include Auto-Ranging capability, and True RMS for measuring both AC Current and Voltage
-
AV-25V-GC1-05 -
Criterion Instruments Limited
This tester is designed for testing equipment wiht a line cord which can be plugged directly to the tester. The continuity test is to determine whether the ground wire of the line-cord is well connected to the metal frame of the unit under test.
-
MD251 -
Matco Tools
*Provides readings for volts, amps and ohms required for automotive electrical system tests, as well as diode and continuity tests*Beep-Jack audible warning beeps against improper a-terminal plug in and decreases the risk of damage
-
369A910 -
Di-Log
The only check box to provide comprehensive verification of 17th Edition and PAT test equipment. The Powercheck tests for full earth continuity, insulation, resistance, RCD trip time, RCD trip current, touch current and flash test verification.
-
1851 IN -
Standard Electric Works Co., Ltd
● Measures insulation (MΩ), Continuity (Ω) and AC voltage.● Three insulation test voltages(DC V) : 250V, 500V, 1000V.● 3½ digital LCD (2000 counts).● 68 × 34mm (2.677” × 1.338” ) large LCD display.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA load.● 210mA short circuit testing current for continuity.● External voltage warning indication.● Fuse protection.● BS 16 edition
-
1152 MF-M -
Standard Electric Works Co., Ltd
● High Contrast OLED display.● Designed for viewing in the dark, for mining industry.● Auto-range microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto-discharge on all tests and all ranges.● Leads auto-null key.● Test auto-stop.● Smart hold and stop on voltmeter AC/DC.● Ener-Save.● Continuity short circuit >220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Polarization index (PI).● Dielectric Absorption Ratio (DAR).● BS 16 edition.