Showing results: 601 - 615 of 1606 items found.
-
-
-
85130D -
Keysight Technologies
The Keysight 85130D test port adapter protects the test set port from being directly connected to the device under test. These adapters have a special rugged female connector that connects to the network analyzer test port. This special connector does not mate with a standard male connector but converts the rugged test set port to a connection that will mate with the device under test. This set contains a 3.5 mm to PSC-3.5 mm male adapter and a 3.5 mm to PSC-3.5 mm female adapter. The frequency range for these adapters is dc to 26.5 GHz with a return loss of 28 dB or better.
-
85130H -
Keysight Technologies
The Keysight 85130H test port adapter protects the test set port from being directly connected to the device under test. This adapter has a special rugged female connector that connects to the network analyzer test port. This special connector does not mate with a standard male connector but converts the rugged test set port to a connection that will mate with the device under test. This set contains a 1.85 mm to 1.85 mm male adapter and a 1.85 mm to 1.85 mm female adapter. The frequency range for these adapters is dc to 67 GHz with a return loss of 23 dB or better.
-
510109118 -
Virginia Panel Corporation
Interconnect Adapters funnel wiring from modules to a VXI card. The adapter has removable side, top and bottom plates. Connector cover plates and cable clamps are ordered separately.
-
Keysight Technologies
The Keysight U1180A thermocouple adapter and lead set are compatible with all series of Keysight Handheld Digital Multimeters. The set includes a J/K type Thermocouple adapter, thermocouple bead J-type and a thermocouple bead K-type.
-
PACC-ZD006 -
Teledyne LeCroy
Small IC adapter for ZD differential probeQty 2
-
PACC-ZD005 -
Teledyne LeCroy
Swivel tip adapter for ZD differential probeQty 1
-
X281A -
Keysight Technologies
The Keysight X281A adapter transforms waveguide transmission line into 50-ohm coaxial line. Power can transmitted in either direction, and each adapter covers the full frequency range of its waveguide band with SWR less than 1.3.
-
85130F -
Keysight Technologies
The Keysight 85130F test port adapter protects the test set port from connecting directly with the device under test. It has a special rugged female connector designed for connecting to the network analyzer test port. This special connector does not mate with a standard male connector but converts the rugged test set port to a connection that will mate with the device under test. The set contains a 2.4 mm to PSC-3.5 mm male adapter and a 2.4 mm to PSC-3.5 mm female adapter. The frequency range for these adapters is dc to 26.5 GHz with a return loss of 26 dB or better.
-
85130G -
Keysight Technologies
The Keysight 85130G test port adapter protects the test set port from connecting directly with the device under test. It has a special rugged female connector that connects to the network analyzer test port. This special connector does not mate with a standard male connector but converts the rugged test set port to a connection that will mate with the device under test. This set contains a NMD-2.4 mm (f) to NMD-2.4 mm (m) adapter and a NMD-2.4 mm (f) to PSC-2.4 mm (f) adapter. The frequency range for these adapters is dc to 50 GHz with a return loss of 23 dB or better.
-
-
-
-
PACC-ZD001 -
Teledyne LeCroy
Y lead Adapter for ZD differential probes Qty 1