Showing results: 421 - 435 of 581 items found.
-
Orbit Controls AG
Transmitters are used for industrial applications to convert process signals into standardized isolated output signals 0-10V or 0 / 4-20mA. In addition to the process signals, various sensors can also be connected, e.g. Pt-100, thermocouples, potentiometric sensors, inductive, capacitive and optical initiators, resistors, etc. The transmitters are supplied with 230VAC or 24VDC and housed in a DIN housing for 35mm rail mounting.
-
Dewesoft d.o.o.
Our temperature data loggers and temperature recorders allow temperature logging from any temperature sensor type like thermocouples, RTDs, and thermistors. Temperature loggers are modular by design and can expand from 1 to 1000's of temperature measurement points. Simple to set up and use. Free award-winning Dewesoft X data acquisition software included.
-
S1500 Series -
Huato Electronic co., ltd
The S1500 series product is a portable paperless data logger. With 8/12/16 channel universal input and thermocouple input function, it can detect thermocouple, RTD, NTC, DC current, DC voltage, frequency, pulse count and other signals at the same time, and the collected data can be vividly displayed through various forms such as digital interface, bar graph interface, real-time curve, etc. The device has rich peripheral interfaces such as USB, TF card, RJ45, WIFI, etc. It is a portable recording instrument with rich functions, highly integrated and intelligent.
-
Universal Testing Device -
Delphin Technology AG
The universal testing device is intended for a diverse range of measurement and automation tasks in laboratories and in test engineering. Thermocouples, RTDs and other sensors can be directly connected. Electrical AC/DC values can also be acquired with the universal testing device.
-
Tempsens Instrument Pvt. Ltd.
Tempsens offers a complete range of temperature calibration types of equipment for calibration of Contact Type Sensors (Thermocouple, RTD) and Non-Contact Type Sensors (Pyrometer). Our Calibration range is from -196°C to 3200°C
-
IT Series -
Physitemp Instruments
Physitemp multisensors are made with our specially manufactured thermocouple wire. We test and grade this wire to standards better than the accepted ''Special Limits of Error'' and guarantee 0.1°C accuracy in the range of 0-50°C . All multisensor probes conform to NIST standards. These multisensor probes are custom-made and should be ordered to your requirements on number of sensors and spacing between sensors.
-
WIKA Alexander Wiegand SE & Co. KG
Temperature transmitters convert the input signal from a wide range of sensors, such as resistance sensors and thermocouples, but in some cases also from potentiometers, into a standardised output signal (e.g. 0 ... 10 V or 4 ... 20 mA). With digital temperature transmitters, the sensor type and the measuring span can be freely configured, along with many further options such as the error signalisation or a measuring location identification.
-
AMETEK VTI Instruments
The RX product family includes 24-channel IEPE/voltage instruments (RX0424), 24-channel high performance bridge measurements (RX0124), 24-channel high performance charge vibration measurements (RX0224), and 32-channel thermocouple measurement systems (RX1032).VTI Instruments’s family of rugged instrumentation is designed and built to operate in some of the most extreme environmental conditions imaginable, without compromising measurement accuracy or performance.
-
781510-01 -
NI
16-Channel, 68 S/s Aggregate, ±78 mV, Isothermal C Series Temperature Input Module - The NI‑9214 is a high-density thermocouple input module that is designed for higher channel count systems. The NI‑9214 includes features to increase overall accuracy, such as CJC sensors in the terminal block, component layout to minimize thermal gradients, and an autozero channel for offset error compensation.
-
855 -
TEGAM Inc.
The ideal solution for anyone that needs a hand held, multi-purpose calibrator to perform field or lab tests on temperature probes or thermometers. The 855 meter will simulate, source, measure and record the same thermocouple types as the 850, K-J-T-E, and adds N-B-R-S-G-C-D types. The meter also supports 1000, 100k, 100 RTD''s but does not support thermistor''s.
-
APCI-3200-16 -
TEAM SOLUTIONS, INC.
18-bit resolution, 16-bit accuracyEach channel can be configured either for thermocouples/RTD or as an analog voltage input channel16 analog input channels for thermocouple typesJ, K, T, E, R, S, B, N - or 8 diff. analog input channels for the acquisition of resistance temperature detectors (Pt100)- or 16 SE/8 differential analog voltage input channels, ± 2.5 V8 independent current sources for resistance temperature detectors (RTD) and one current source for cold junction compensationCold junction compensation (on separate screw terminal board PX 3200)Gain and offset calibrationLinearisation through table and calculation for the thermocouple types J, K, T, E, R, S, B, N and RTDsProgrammable gain16-bit accuracy with sample rates of 20, 40, 80 or 160 Hz (other rates on request)4 digital input channels, 24 V and 3 digital output channels, open collector, isolated
-
APCI-3200-4 -
TEAM SOLUTIONS, INC.
18-bit resolution, 16-bit accuracyEach channel can be configured either for thermocouples/RTD or as an analog voltage input channel4 analog input channels for thermocouple typesJ, K, T, E, R, S, B, N - or 2 diff. analog input channels for the acquisition of resistance temperature detectors (Pt100)- or 16 SE/8 differential analog voltage input channels, ± 2.5 V8 independent current sources for resistance temperature detectors (RTD) and one current source for cold junction compensationCold junction compensation (on separate screw terminal board PX 3200)Gain and offset calibrationLinearisation through table and calculation for the thermocouple types J, K, T, E, R, S, B, N and RTDsProgrammable gain16-bit accuracy with sample rates of 20, 40, 80 or 160 Hz (other rates on request)4 digital input channels, 24 V and 3 digital output channels, open collector, isolated
-
ILA -
Dwyer Instruments Inc.
10:1 Distance to Target Ratio, 32 to 932F. Dwyer Series ILA Non-Contact Sensors, measure temperatures from 32 to 932F (0 to 500C) and provide a linear 4 to 20 mA, 0 to 5 VDC or thermocouple output. The 2-wire signal is compatible with almost any indicator, controller, recorder, data logger, etc., without the need for special interfacing or signal conditioning.
-
CMP 6 -
Kipp & Zonen B.V.
The CMP 6 pyranometer is intended for routine global solar radiation measurement research on a plane/level surface.Fully compliant with ISO-9060 specification for a First Class pyranometer, the CMP 6 features a sixty-four thermocouple junction (series connected) sensing element. The sensing element is coated with a highly stable carbon based non organic coating, which delivers excellent spectral absorption and long term stability characteristics
-
AMETEK Sensors, Test & Calibration
Our calibration software provides an easy way to calibrate gauges, RTD´s, thermocouples, transmitters, thermoswithes, and pressure switches. Complete a full calibration from entering the details of the gauge to printing out a calibration certificate. Reduce operating time by automating calibration procedures, reduce sources of error by automatically reading and storing values from the reference, and customize certificate templates to fit your needs.