Filter Results By:

Products

Applications

Manufacturers

Thermocouples

Thermocouples are junctions of two dissimilar metals that produce a very small voltage proportional to the temperature of the junction.


Showing results: 526 - 540 of 581 items found.

  • Ammeter

    AC Rectifier Type Coil Meter - Bee Instruments

    measures the alternating voltage and current with the help of rectifying elements and permanent magnet moving coil type of instruments. However the primary function of rectifier type of instruments work as voltmeter. Now one question must arises in our mind why we use rectifier type of instruments widely in the industrial world though we have various other AC voltmeter like electrodynamometer type instruments, thermocouple type instruments etc? The answer to this question is very simple and is written as follows.

  • NI-9219, 100 S/s/channel, 4-Channel C Series Universal Analog Input Module

    779781-02 - NI

    100 S/s/channel, 4-Channel C Series Universal Analog Input Module - The NI‑9219 is designed for multipurpose testing. With the NI‑9219, you can measure signals from sensors such as strain gages, resistance temperature detectors (RTDs), thermocouples, load cells, and other powered sensors, as well as make quarter-bridge, half-bridge, and full-bridge current measurements, with built-in voltage and current excitation. Each channel is individually selectable, so you can perform a different measurement type on each channel.

  • NI-9219, 100 S/s/channel, 4-Channel C Series Universal Analog Input Module

    785994-01 - NI

    100 S/s/channel, 4-Channel C Series Universal Analog Input Module - The NI‑9219 is designed for multipurpose testing. With the NI‑9219, you can measure signals from sensors such as strain gages, resistance temperature detectors (RTDs), thermocouples, load cells, and other powered sensors, as well as make quarter-bridge, half-bridge, and full-bridge current measurements, with built-in voltage and current excitation. Each channel is individually selectable, so you can perform a different measurement type on each channel.

  • Combustion Check Gas Analyzer

    KM 5410 - Kusam Electrical Industries Limited

    * Hand-pump with filter to isolate dirt and particles.* Thermocouple offset adjustment ±3°C (6°F).* Automatic power off battery saver.* 2 channel display(LCD).* Display Back-Light.* Analyzer Directly Measures: Flue Gas Oxygen Content in % and Flue Gas Temperature in °F or °C* Analyzer Computes: When the measured oxygen level is below 17.9%, Flue Gas Carbon Dioxide content in %, , Excess Air in %(0 to 400%), Flue Natural Gas/Oil #2/Propane in %

  • MINX Sensors

    MINX0003 - ExpressSense

    ExpressSense introduces the MINX sensor suite, a plug-and-play sensor solution, featuring five built in sensors, delivering automatically-generated process control charts as a web page, viewable from any network connected device. User configured triggers enable email or text alerts to inform user when specific conditions are detected, or MINX can automatically control another device or machine. MINX can be installed and setup in as little as 10 minutes. MINX includes all hardware and software, plus no subscriptions are needed and all the data is kept locally on the unit for maximum security and value!MINX Sensors: Ambient Temperature & Humidity; Optical distance or count optical events; Measure shock/vibration/acceleration amplitude or count events; Remote Temperature via thermocouple; Measure user supplied external analog sensor (0-5V or 0-20mA), either amplitude or record events .

  • Miniature Digital Panel Meter

    CSMS-321 - Power True Systems Corp.

    Measuring DCA, DCV, Temperature. 1/32 DIN Size ( 48mmX24mm ). Accuracy: +/- 0.1%(DC), +/- 1%(Thermocouple), +/- 0.2%(Pt100). 3 1/2 Digits Display: 1999. Input Max. 2Adc +/- 10%; 300Vdc, T/C type K: 1200J, Pt100:600J. Aux Power 5Vdc +/- 10%; Isolated Aux. Power 5Vdc, 12Vdc, 24Vdc available in option. Easy to wire, screw type terminal. Outside dimensions is 1/32 DIN Standard ( 48 x 24mm ). High stability & low cost.

  • Limits and Scanners

    Watlow Electric Manufacturing Company

    Various configurations offer user-selectable or fixed-configuration sensor options including thermocouple, process, RTD and thermal switch inputs as well as user-settable or fixed limit values. Models with displays have user-selectable temperature units. Other features include sensor break protection, industry standard I/O options and UL® and CSA approval. EZ-ZONE models are RoHS compliant. Limits have FM approval for performance in safety limit applications. Watlow limits are designed and manufactured to withstand harsh industrial environments and come with a three-year warranty.

  • Hygro-Thermometer/Datalogger

    Extech SDL500 - Extech Instruments Corporation

    The SDL500 records data on an SD card in Excel format. Relative Humidity, Temperature, Dew Point, and Wet Bulb measurements. Adjustable data sampling rate. Stores 99 readings manually and 20M readings via 2G SD card. Type K/J Thermocouple input for high temperature measurements. Large backlit dual LCD display. Record/Recall Min, Max, Data Hold and Auto power off functions. Complete with 6 x AA batteries, SD card, carrying case and Humidity/Temperature probe.

  • Turnkey Data Acquisition Systems

    Series 6800 - Pacific Instruments, Inc.

    Based completely on the Series 6000 hardware and software platform, Series 6800 is a turnkey system configured for specific measurement types and environments. Systems are available for Strain/Bridge, Voltage/IEPE, Thermocouple and packaged for laboratory or portable applications. Systems range in channel count from 8 to 128 channels and can be easily expanded, should test requirements change. Included turnkey software helps facilities focus on testing, not developing software. If you don’t see a configuration that fits your application, we can likely build a system specific to your needs.

  • Type-K Pipe Clamp Temperature Probe (-4 to 200°F)

    Extech TP200 - Extech Instruments Corporation

    The Extech TP200 Type-K Pipe Clamp Temperature Probe produces a hands-free, super heat and sub cooling temperature measurement. The spring-loaded jaw ensures a secure grip on pipes from 6.35 mm (0.25 in) to 38 mm (1.5 in) in diameter. This probe can be used with any thermometer or multimeter with a Type-K thermocouple input. The measurement range is from -20°C to 93°C (-4°F to 200°F) with and accuracy of ±1.8°C (3.6°F). The TP200 comes complete with an attached 0.9 mm (36 in) cable and a Type-K connector.

  • sbRIO-9219, Non-Enclosed, 100 S/s/channel, 4-Channel C Series Universal Analog Input Module

    781027-01 - NI

    Non-Enclosed, 100 S/s/channel, 4-Channel C Series Universal Analog Input Module - The sbRIO‑9219 is designed for multipurpose testing. With the sbRIO‑9219, you can measure signals from sensors such as strain gages, resistance temperature detectors (RTDs), thermocouples, load cells, and other powered sensors, as well as make quarter-bridge, half-bridge, and full-bridge current measurements, with built-in voltage and current excitation. Each channel is individually selectable, so you can perform a different measurement type on each channel. Non-enclosed modules are designed for OEM applications.

  • BNC-2120, 68-Pin Female SCSI to Female BNC and Screw Terminal, DIN Rail, Desktop Mount, Shielded Terminal Block

    777960-01 - NI

    68-Pin Female SCSI to Female BNC and Screw Terminal, DIN Rail, Desktop Mount, Shielded Terminal Block - The BNC-2120 can be used with various NI multifunction I/O and analog output devices. The BNC-2120 simplifies the connection of analog signals, some digital signals, and two user-defined connections to the data acquisition device while maintaining the integrity of your measurements with a shielded enclosure. It also features a function generator, quadrature encoder, and cold junction compensation for thermocouple measurements. The BNC-2120 includes a DIN Rail and a desktop mount option.

  • Data Acquisition System

    DAQ - North Atlantic Industries

    Data Acquisition (DAQ) systems are used to collect information for the purpose of documenting or analyzing an electrical or physical phenomenon, for example: temperature or pressure. They serve as a focal point in tying a wide variety of sensors together that indicate temperature, flow, level or pressure. The sensors convert a physical occurrence into a measurable electrical signal, which can be factored into command and control decisions. These high-speed DAQ systems feature different analog and digital input and output modules that can be used with a wide range of signal types including 4-20 mA current, thermocouples, and RTDs.

  • Multiplexed- Low-Level Function Card

    Neff Instrument Corporation

    Low-level multiplexed systems have a single programmable gain, wide-band amplifier following the input multiplexer. To accommodate low-level signal signals such as those from strain gauges or thermocouples and at the same time high level signals from other sources, the throughput rate must be limited to enable the high bandwidth amplifier to settle to the correct value after switching to a new channel. This results in a relatively low aggregate throughput rate when compared to an amplifier-per-channel system. A major benefit of a well designed low-level multiplexed system is the extremely high performance/cost relationship.

  • Datapaq Solar Tracker System

    Fluke Process Instruments

    The SolarPaq® Thermal Profiling Systems from Fluke Process Instruments are designed specifically for solar photovoltaic (PV) manufacturing including applications like contact firing, contact drying, anti-reflection coating for the solar cell, lamination and other thin film processes. These systems, consisting of user-friendly Insight™ software, Datapaq® Q18 data loggers, stainless steel thermal barriers, thermocouples with PTFE or mineral insulation and accessories, provide users with the tools needed to gather accurate, repeatable results for process optimization, maximize cell efficiency and throughput, and more.

Get Help