Showing results: 346 - 360 of 473 items found.
-
IMV Corporation
A compact Signal Amplifier to make optimal signal processing being connected with the Servo type Accelerometers. It is used for Vibration Acceleration Measurement, Waveform Observation, for various Analysis in combination with the AC Voltage Meter, Oscilloscope, FFT Analyzer respectively. Furthermore, Voltage signals from the Microphones or Sound Level Meters can be output to the instruments like Recorders along with the Vibration Signals.
-
Dewesoft d.o.o.
Our temperature data loggers and temperature recorders allow temperature logging from any temperature sensor type like thermocouples, RTDs, and thermistors. Temperature loggers are modular by design and can expand from 1 to 1000's of temperature measurement points. Simple to set up and use. Free award-winning Dewesoft X data acquisition software included.
-
TGU-4510 -
Gemini Data Loggers Ltd.
Dual channel temperature recorder 32,000 readings capacity High accuracy and reading resolution Fast data offload Splashproof case Low battery monitor User-replaceable battery USB or serial download cables User-programmable alarms
-
Astronics Corporation
The TS 717 Test Set for ARINC 717 is a convenient, easy-to-use tool for test and maintenance of aircraft systems that are tied to the Digital Flight Data Recorder (DFDR). The compact interface/cable hardware is conveniently stored in a rugged carrying case for easy transport and quick deployment.The webFLT™ is a wireless functional tester for aircraft systems using the Digital Flight Data Recorder ARINC 717 bus. It connects directly to the aircraft system test plug and transfers data to the test computer via an 802.11 b/g wireless link, eliminating cabling in the crowded cockpit that can be tripped over or damaged.
-
201LP -
Datatest Inc
The Redkoh Model 201LP is a three wire particulate monitor that measures particulate levels in air ducts on a real time basis. The Model 201LP is powered by an external 24V dc supply and its continuous 4-20 ma output can be connected directly to a PLC, recorder, or digital readout. Changes in the 4-20 ma output are directly related to changes in the concentration of particulate in the gas stream.
-
ST-8850 -
Standard Instruments Co., LTD.
This digital meter is ideal for general sound level measurements. The device features analog AC/DC outputs for connecting to an analyzer or recorder. Coming with a wide range of 30dB to 130dB, this sound level meter is great for measuring noise in factories and checking acoustics in auditoriums. 1.5dB accuracy. Meets IEC651 type 2 standard. Max. hold and data-hold functions. Built-in calibration check.
-
DEFI2-T -
JFE Advantech Co., Ltd.
DEFI2-T is a high-precision miniature water temperature recorder for long-term observations (approx. 573 days for 1 minute interval observation). The reduced size of the DEFI2-T allows the device to be installed in large numbers in a single mooring system, allowing investigating temperature fluctuations at increased spatial resolution. Also, AAA alkaline batteries used by DEFI2-T are easily available, reducing the operating costs.
-
Telerik A.D.
Automated testing has come of age with Progress® Telerik® Test Studio. With the industry's fastest test recorder, its patent-pending mixed element find logic makes tests more stable and reliable while keeping test maintenance to a minimum. Test Studio maximizes test coverage ensuring optimal app quality and addresses QA’s top challenges.
-
HIOKI E.E. Corp
While Memory Hicorders don’t have sampling speeds that are as fast as those of digital oscilloscopes, these waveform recorders can be used to record various types of signals without worrying about potential differences between them and without using isolation amplifiers.
-
Smartech Inc.
*Max & Min Measurement*Over Range Display*Under range display*A & C Weighting*FAST & SLOW response*Analog AC/DC Outputs for connection to frequency analyzer or X-Y shaft recorder*Datalogger function*Adjustable Alarm Levels*Backlight
-
TGU-4017 -
Gemini Data Loggers Ltd.
Self-contained temperature recorder Delayed start option 32,000 readings capacity High accuracy and reading resolution Fast data offload Splashproof case Low battery monitor User-replaceable battery USB or serial download cables User-programmable alarms
-
ILA -
Dwyer Instruments Inc.
10:1 Distance to Target Ratio, 32 to 932F. Dwyer Series ILA Non-Contact Sensors, measure temperatures from 32 to 932F (0 to 500C) and provide a linear 4 to 20 mA, 0 to 5 VDC or thermocouple output. The 2-wire signal is compatible with almost any indicator, controller, recorder, data logger, etc., without the need for special interfacing or signal conditioning.
-
SIGNAL 5 -
Engineering Design
SIGNAL 4.0 provides a powerful graphical environment for viewing, measuring, and manipulating signals, while retaining all the programmability of SIGNAL 3.1. SIGNAL 4.0 is easy to learn and convenient to use. New features include multi-window graph displays with multiple measurement cursors and flexible zooms, drag-and-drop layout for publication graphs, an on-screen spreadsheet for screen measurements, a macro recorder for easy programming,
-
OS-2000 Series -
Ono Sokki
OS-2000 series have been received well as time-series data analysis software which can perform flexible data-edit from huge amount of time-series data. The OS-2000 series can handle original format of other company's recorder and general-purpose formats of CSV and WAVE. In addition, simultaneous display, layout and overlapping can be performed smoothly without restrictions by the kind of data format or the number of sampling frequency.
-
W-M-350 -
James Instruments Inc.
The W-M-350 Recording Test Hammer gives you the same quality as the W-M-250 but with the added feature of a built-in automatic chart recorder. Every test you take is automatically recorded as a bar chart on a paper strip.This creates a field record to verify your findings.In addi- tion to this paper record,you can see each test as it happens through the large easy to read window