Showing results: 181 - 195 of 219 items found.
-
0001-011 -
VI Control Systems Ltd.
A general purpose interface board for Mircromint's Answer Man Junior. Jumpers select one of three communication interfaces (RS-232, RS-485, or fiber optic RS-232). 12 bit ADCs and DACs are added for higher precision AD conversions. Answer Man Junior is included with the board.
-
Elmeasure India Pvt. Ltd
Multiple branches of load can be monitored togetherCan group the device as 3 phase load and single phase loadFaster communication through RS485 port (Modbus protocol)Simultaneous sampling of Volts and AmpsAccuracy Class 1.0 as per IEC 62053-21 & Class 0.5 as per IEC 62053-22 StandardsDisplays more than 25 parameters
-
EZA Series -
TDK-Lambda Corp.
*1U Rackmount Bidirectional Isolated DC-DC*2.5 kW: 48 Vdc (Battery) Û 320 Vdc (Grid)*11 kW: 240 Vdc (Battery) Û 320 Vdc (Grid)*2.2 kVac up to 3 kVac Isolation*High Efficiency > 92%*RS-485 Communications and Control*For Energy Regeneration applications
-
T8448 -
COMET SYSTEM, s.r.o.
CO2 concentration and temperature transmitter with serial RS485 output is specially designed for use in exacting interiors in building energy management and HVAC systems. It designed for easy installation on ordinary KU68 wiring boxes for household switches and sockets. Large dual line LCD is possible to switch off. Computerized design ensures long term stability and fail indication. Transmitter is designed for use in non-aggressive environment.
-
SparkFun Electronics
This is the newest revision of this board and this breakout board pairs an SP3485 RS-485 transceiver with an FT232RL USB UART IC to convert a USB stream to RS-485. The SP3485 is a half-duplex transceiver, so it can only communicate one way at a time, but it can reach transmission speeds of up to 10Mbps.
-
Analog Devices Inc.
The RS-485 specification meets the requirements for a truly multipoint communications network, and the standard specifies up to 32 drivers and 32 receivers on a single (2-wire) bus. Some RS-485 transceivers modify the input impedance to allow up to 8× more nodes to be connected to the same bus. Analog Devices offers a wide range of standard RS-485/RS-422 transceivers and iCoupler® isolated RS-485/RS-422 transceivers to suit many applications.
-
Wuntronic GmbH
RS485 Temperature, Humidity, Atmospheric Pressure and CO2 Transducers.
-
LAP-16128U -
Zeroplus Technology Corperation
Sample rate (Internal clock): 200MHz asynchronous operation. Sample rate (External clock): 100MHz synchronous operation. Channels may be selectively defulted to /Channels: 16 CH. Upgrade Oscilloscope to measure and decode I2C / UART (RS232C & RS485) / SPI Protocols and mixed signals.
-
LAP-16064U -
Zeroplus Technology Corperation
Sample rate (Internal clock): 100MHz asynchronous operation. Sample rate (External clock): 100MHz synchronous operation. Channels may be selectively defulted to /Channels: 16 CH. Upgrade Oscilloscope to measure and decode I2C / UART (RS232C & RS485) / SPI Protocols and mixed signals. Glitch Capture Capability: 5ns. Bandwidth: 75MHz.
-
LAP-321000U-A -
Zeroplus Technology Corperation
Sample rate (Internal clock): 200MHz asynchronous operation. Sample rate (External clock): 100MHz synchronous operation. Memory Depth (per channel): 1MbitsChannels: 32CH. Upgrade Oscilloscope to measure and decode I2C / UART (RS232C & RS485) / SPI Protocols and mixed signals. Glitch Capture Capability: 5ns. Bandwidth: 75MHz.
-
ND-6510 -
ADLINK Technology Inc.
ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.
-
ND-6520 -
ADLINK Technology Inc.
ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.
-
Model 290 -
Telebyte, Inc.
FEATURES: Break RS-485 Limit, Expand to 496 Nodes 16 Port Capacity; Each Port Settable to RS-422 or 2 Wire RS-485; Provides Isolation Between Ports; All Ports Surge Protected; Increased System Reliability. The Model 290 RS-232 to RS-422/RS-485 Concentrator offers a unique group of features for those applications using RS-422 and/or RS-485 for communications between a multiplicity of devices.
-
104i-COM-8SM Family -
Acces I/O Products, Inc.
The 104i-COM-8SM (PCI-104) family of multi-port, multi-protocol (RS-232, RS-422, RS-485), serial communication boards deliver up to eight high-speed serial communication ports for use in a wide variety of applications. The boards were developed for use by system integrators and manufacturers in the design of industrial and commercial systems. Based on the XR17D158, the boards have eight enhanced 16550 UARTs, each with a set of modem signals (CTS, RTS, RI, DTR, DSR, CD) in RS-232 mode. Each UART has both a 64 byte transmit and a 64 byte receive FIFO. Ports are accessed via two 40-pin IDC type right angle header connectors. 2 and 4-port versions are available, as well as RS-232 only models.
-
ECD485 -
EDMI Ltd.
Deploy sub-metering sites and simple metering networks with ease using the EDMI MiniHub RS-232 to RS-485 converter.1/4 Load RS-485 modules allow for up to 128 devices over 1.2km of wired daisy-chain network, with each meter capable of becoming the Network Master and remotely connecting to a backhaul system via an integrated EDMI Modem Port redirect connector.