Showing results: 196 - 210 of 219 items found.
-
ND-6530 -
ADLINK Technology Inc.
ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.
-
THI Sensors -
Ducati energia S. p. A.
The THI-485 sensors are Modbus transducers for measuring thesurrounding temperature and relative humidity or for theacquisition of up to four passive pulse signals or digital states. This feature extends the possibilities of the device, turning it into a kind of RS485 pulse concentrator from other sensors andmeters.
-
MODG-100 -
proconX Pty Ltd
MODG-100 is a Modbus/TCP to Modbus RTU gateway. Itfeatures one serial port which can be configured as either RS-232, RS-485 or RS-422 and an Ethernet port. It can be mounted on a DIN rail.
-
Rishabh Instruments Pvt. Ltd.,
Module of logic outputs. Control of actuators from monitoring systems or PLC over RS485. 4 relay outputs or 8 OC outputs steered through RS-485/Modbus. Fixing on a TS35 rail. Full galvanic separation between outputs (for relay outputs). Configuration through free LPConfig software.
-
-
SPC - INS - 1010 -
Signals & Systems India Private Limited
The IRIG-B TTL signal is a time synchronization protocol that can be transmitted up to 50m maximum using coaxial cable. So the relay which is to be received the IRIG-B TTL signal may be far away from the IRIG-B source. The relay may be not able to synchronize with the GPS. To avoid such an incident in the field, some of the relays have provision to receive IRIG-B RS485 signal. The IRIG-B RS485 signal can able travel up to 1200m without any booster. All Time source equipment may not be supplied with IRIG-B RS485 signal output. The converter will act as a bridge between GPS Time source and Relays for time synchronization.
-
778674-01 -
NI
10-Pin Female RJ50 to 10-Pin Female Screw Terminal, DIN Rail, Serial Communication Terminal Block - The CB-485A is a connector block for RS-485 serial communication over RJ50 cables that mounts to the DIN rail. It features ten screw terminals and a female RJ50 connector.
-
183283-04 -
NI
9-Pin Female DB-9 to 9-Pin Female DB-9 Serial Cable - The 9F-9F Serial Cable, sometimes referred to as GPIB Serial Cable, connects and controls GPIB devices using RS232 and RS485 serial ports. The 9F-9F Serial Cable is offered in different lengths.
-
183283-02 -
NI
9-Pin Female DB-9 to 9-Pin Female DB-9 Serial Cable - The 9F-9F Serial Cable, sometimes referred to as GPIB Serial Cable, connects and controls GPIB devices using RS232 and RS485 serial ports. The 9F-9F Serial Cable is offered in different lengths.
-
183283-01 -
NI
9-Pin Female DB-9 to 9-Pin Female DB-9 Serial Cable - The 9F-9F Serial Cable, sometimes referred to as GPIB Serial Cable, connects and controls GPIB devices using RS232 and RS485 serial ports. The 9F-9F Serial Cable is offered in different lengths.
-
Advantech Co. Ltd.
ADAM remote I/O are categorized into 5 families: IoT/OPC UA Ethernet I/O, Modular I/O system, RS-485 I/O and Serial/USB Converters/Repeaters.
-
ADAM-4000/4100 Series -
Advantech Co. Ltd.
The ADAM-4000/ 4100 series featuring rugged industrial-grade cases are specially designed for reliable operation in harsh environments. Built-in microprocessors independently provide intelligent signal conditioning, analog I/O, digital I/O, data display, and RS-485 communication through Modbus RTU protocols.
-
-
Model 8021NX -
Telebyte, Inc.
FEATURES: Fast Response; Automatic Recovery; Up To 20 MBPS Data Rate; DIN Rail Mounted; Triple Stage Protection; Two Wire. The Model 8021NX is a DIN Rail mounted surge suppressor for 2-wire RS-485 circuits used to protect factory data networks, or, any RS-485 network that wants to avail itself of the DIN Rail packaging concept. The Model 8021NX provides common-mode (line to ground) surge protection and differential mode (line to line) protection for balanced networks. All the inputs, outputs and ground connections are via screw terminals located on the top surface of the device.
-
SP-RS485-12V-O -
Network Technologies Inc
Ideal for applications such as video surveillance cameras and access control. Protects sensors running on 22 AWG 2-wire sensor cables or 12VDC power lines against the effects of electrostatic discharge, faulty wiring and lightning. RS485 protection: Stage 1 clamping voltage: ±90V; Stage 2 resistance: 3.3 Ohms; Stage 3 clamping voltage: ±7.5V. 12VDC power lines protection: Stage 1 clamping voltage: ±90V; Stage 2 current rating: 3A; Stage 3: 12V TVS (transient voltage suppression) diode. Screw terminal pairs for RS485 and 12VDC power lines protection. Will also protect two single ended data, analog or control lines. Impact and weather resistant enclosure with locking hinged cover.