Filter Results By:

Products

Applications

Manufacturers

Shunts

An Instrument Shunt is a resistor connected in parallel with a measuring device to move the current range beyond a particular value for which the instrument is capable of measuring directly.

See Also: Current Shunts


Showing results: 121 - 135 of 135 items found.

  • Dual Wide Range Power Monitor

    LTC2992 - Analog Devices Inc.

    The LTC®2992 is a rail-to-rail system monitor that measures current, voltage, and power of two supplies. It features an operating range of 2.7V to 100V and includes a shunt regulator for supplies above 100V. The voltage measurement range of 0V to 100V is independent of the input supply. Two ADCs simultaneously measure each supply’s current. A third ADC monitors the input voltages and four auxiliary external voltages. Each supply’s current and power is added for total system consumption. Minimum and maximum values are stored and an overrange alert with programmable thresholds minimizes the need for software polling. Data is reported via a standard I2C interface. Shutdown mode reduces current consumption to 25μA typically.

  • Wide Angle Scale Instrument

    LS-96 - Standard Electric Works Co., Ltd

    ● For ranges higher than 20A DC, use external shunt with a 50mV DC Ammeter.● For ranges higher than 300V DC, use external Volt Divider with a 1mA Voltmeter.● For ranges higher than 5A AC, use external Current Transformer with a 5A AC Ammeter. ● For ranges higher than 600V AC, use external Potential Transformer with a 150V AC Voltmeter.● Full Scale Deflection : 250° ● Accuracy : Class 1.5● Composition : Glass window, ABS resin frame and case, PC glass fiber base mounting fittings included.● Color : Black base and frame, white scale plate and meter body.● Pointer : Stick shape in black color.

  • Load Cell Amplifier Signal Conditioner with DB9 Connectors

    MODEL LCA-9PC - Transducer Techniques, Inc

    The LCA-9PC Module provides low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-9PC comes with DB9 male and female connectors, which require soldering to user-furnished mating female or male wire connectors. On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film otentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.

  • Load Cell Amplifier Signal Conditioner with Removeable Terminals

    MODEL LCA-RTC - Transducer Techniques, Inc

    The LCA-RTC Module provide low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-RTC comes with removable screw-clamp terminal connectors, which accept wires without soldering.On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film potentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.

  • Differential Voltage Probes

    DP150/DP200pro - Powertek LLC

    The DP differential isolation probes are an important accessory for any laboratory involved in power electronics and high voltage systems. These probes allow isolated and floating measurements with any oscilloscope or data recorder, whilst the oscilloscope can remain grounded. Using a DP150 or DP200pro probe, differential and floating measurements can be made on a variety of ac power systems like 230V/110V ac input power supplies, chopped and switching power supplies, thyristor controllers, variable speed motor drives (PWM signals), motor inrush current and measurement across current shunts. The isolated input is made via two 4mm/banana safety sockets. The BNC output allows easy connection to an oscilloscope. The DP probes can be powered from a 9V battery or external power supply.

  • Multiphase Power Analyzer

    2800 Series - Valhalla Scientific Inc.

    The Valhalla Scientific 2800 High-Precision Power Analyzer is available in 1-, 2-, 3-, 4-, 5-, or 6-phase versions.  All voltage inputs 0.3V up to 1500V peak and all current inputs 1.5mA up to 1A; 15mA up to 5A; 1A up to 40A; and shunt inputs 60mV up to 6V are potentially free and exhibit low noise, high common mode suppression, excellent DC-stability, wide frequency range (DC-2MHz) and very low self-heating on current inputs.There is no need to fiddle with DC-compensation, or changing current plugging.  All is built into the input sections of the power analyzer, ready for measurements.  It is simple to use, your intuition will guide you to operate the Power Analyzer touch screen correctly.

  • ADI Test Fixture

    TA-6500 - Tech-Aid Products

    The TA-6500 test fixture combines the features of the OEM's Instrument Servo Tester(T307962), the Pointer/Flag Test Fixture(T307951) and the AD-650/600 Test Panel(T334043) all into one panel to facilitate testing of these Attitude Director Indicator's. The panel switches and adjustment pots are labeled to match the test procedure numbers and the duplicity in marking makes it easier for the technician to understand each function. The UUT interface is through a 96 pin zero insertion force(ZIF) type connector to minimize contact wear. The expanded localizer and nav input pins J2-34/35 are exposed on the panel to facilitate the insertion of a 200 ohm shunt when required. The fixtures rear panel has connectors for the required dual API/Synchro transmitter interface while the panel switches provide the correct routing of each.

  • Universal Signal Conditioner

    Model UDA - tecsis LP

    Model UDA is a universal signal conditioner and amplifier designed for use with all full bridge, strain gage-based transducers. Model UDA turns the analog signal into a user-selectable output of ±5Vdc, ±10Vdc, or 4-20mA. This versatile unit features selectable excitation of 2.5 or 5.0Vdc bridge voltage and has a wide DC power input range from 11 to 28Vdc to adapt to a variety of installations. Model UDA includes a wide zero and span adjustment range and a symmetry adjustment for applications requiring precision in both tension and compression. The configurable low pass filter actively removes unwanted high frequency signal components. The unit is housed in a rugged DIN-mountable enclosure with screw terminals to provide connection for power, analog output, shunt calibration, and sensor signals.

  • Digital Power Meter, 30A

    66205 - Chroma Systems Solutions, Inc.

    Voltage Ranges:15/30/60/150/300/600 Vrms1200Vrms (optional)Current Ranges : 0.005/0.02/0.05/0.2/0.3/0.5/2/5/20/30 ArmsFrequency Range : DC, 15Hz~10kHzEmbedded high speed DSP, 16 bitsAnalog/Digital converters withmax samipling rate up to 250kHzCapable of meeting the IEC 61000-4-7harmonics measurement requirementsSmart Range function provides seamlesspower integration measurement underauto range modeSupports external shunt and CT forhigher current applications5 mA minimum current range &0.1mW power resolutionMeets ENERGY STAR /EN 50564/IEC 62301/ErP requirementsUser-define criteria providesautomatic PASS/FAIL indicationsTHD and user-specify order distortionmeasurementInrush current and energy measurementsVoltage/ Current harmonics measurementsup to 100 ordersUSB (Host) interface provides data loggingfunctionalitySupport GPIB, USB, RS232, LAN (option)interface

  • Turbine Flowmeters

    Titan Enterprises Ltd

    Titan’s small turbine flowmeter range use a radial flow principle based on the Pelton wheel technique. This well proven method is the ideal way of measuring low rates of flow of low viscosity liquids. For these mini flowmeters, a jet of fluid is directed at a turbine that is mounted on robust low friction sapphire bearings. The geometry of the turbine and the fluid chamber ensures that the rotational speed of the rotor is proportional to the flow rate through the device. The use of this radial arrangement allows more energy to be imparted into the turbine, so the bearing drag is far less important. Furthermore, because more energy is available the bearings themselves can be a lot stronger so increasing the life of the flowmeter. For larger flows, some of the liquid can bypass the turbine chamber, which then behaves as a “shunt” to the metered fluid. Accuracy is still maintained and the output remains linear.

  • FD-11637, 8-Channel Strain/Bridge Input Device for FieldDAQ

    785641-01 - NI

    8-Channel Strain/Bridge Input Device for FieldDAQ - The FD-11637 can measure eight channels and has built-in bridge completion and voltage excitation to support for quarter-, half-, and full-bridge sensors. It also features anti-alias filtering, offset nulling, and shunt calibration to reduce the effect of noise and improve measurement accuracy. The FD-11637 has an ingress protection rating up to IP67 (dust- and water-resistant), can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 grm vibration. The FD-11637 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11637 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. The FD-11637 is ideal for test cell and outdoor environments.

  • Torque Measuring and Monitoring System

    WISER 4000 - TECAT Performance Systems, LLC

    The WISER 4000 system is the latest release of TECAT’s low-cost, ultra-low power and extremely accurate torque sensor. The wireless system has the optional ability to measure 3-axis acceleration, barometric pressure and ambient temperature, all within the same incredibly small footprint. The 4000 includes on-board data logging without PC or DAQ connectivity, and remote flash capability, which enables firmware upgrades without removing the system from the unit under test. Featuring shunt calibration, TECAT’s latest WISER system is designed to simplify instrumentation verification for users, while allowing them to check calibration of the system in the field. In addition, the WISER 4000 has been enhanced with two additional outputs, a higher-speed recording, and is available with custom-built remote enclosures to protect the system’s remote unit and battery from damage due to debris.

  • Life Cyclic Durability Testing

    Environment Associates Inc.

    Environment Associates can provide everything you need for cyclic durability testing and performance fixturing. Services include mechanical cycling to a position or load, fatigue cycling to a fixed load, rotational torque cycling, and simple push/pull cycling. EA can design your fixture with electro-dynamic, air, or hydraulic assistance to mechanically move your part. All of our fixtures can be manufactured to withstand a wide range of temperature, humidity and vibration inputs. If required, forces can be monitored electronically, using a wide variety of inputs (i.e. strain gages, load cells, rotational transducers, thermocouples, shunts, and more). EA can create holding and check fixtures to perform “pre” and “post” evaluation for dimensional issues that may occur during testing. EA can provide fixtures for single tests run internally for EA test labs and can manufacture fixtures to be purchased directly by the customer for their internal use.

  • PXI Based Multifunction Measurement and ICT Instrument

    PXI-501 - Konrad Technologies GmbH

    The PXI-501 is a multifunction measurement instrument for functional and in-circuit measurements.It combines two parametric measurement units with a digital voltmeter, a high voltage current source and a discharge unit. This powerful combination makes it the ideal instrument for classical analog in-circuit test and manufacturing defect analysis with additional functional test capabilities.With it’s fast sampling rate of up to 4MSps it speeds up measurements and is capable of measuring and generating AC signals up to 100kHz.To enhance the PXI-501 capabilities it can be combined with an ABex TM-501 or an ABex TM-404. The ABex TM-501 enhances the in and output range of the PXI-501. Furthermore, it provides a shunt current measurement upgrade. In combination with the ABex TM-404 it’s a complete in-circuit test solution with 86 channels in one ABex slot. For sure it can be upgraded to 2838 test points in one rack by simply adding additional matrix modules.With the above-mentioned terminal modules, the PXI-501 is able to act as a ABex system controller, so that no additional controller is required in the cassis.

  • 6000 Series Analog I/O Modules

    Pacific Instruments, Inc.

    Series 6000 analog I/O modules condition, amplify, filter and digitize signals from virtually any transducer. All modules have conditioning & amplifier per channel and nearly all modules allow for setting bridge completion, shunt calibration, transducer power, gain, etc. individually per channel. Following the conditioning/amplifier stage, multi-pole Bessel or Butterworth analog filters are provided on each channel and can be set or bypassed individually by program control. A number of the modules include a high level analog output providing a conditioned/filtered output to a redundant, external A/D system. A 16-Bit Successive Approximation A/D follows the analog filter stage. Some modules use a single A/D with sample and hold while others have an A/D per channel. Sample rates are programmable per channel to easily accommodate mixing high and low speed measurements into a single data stream. Programmable hardware based warnings and alarms are included in the channel-by-channel architecture and are detected by digital output modules in the system, providing an ultra-low latency control capability directly from the data acquisition system.

Get Help