Filter Results By:

Products

Applications

Manufacturers

Measurement

an acertained value.

See Also: Metrology, Instrumentation, Sensors, Meters, Stability


Showing results: 2266 - 2280 of 10560 items found.

  • Sweep Generator

    G440XE - Elmika

    The G440XE Sweep Generators are portable powerful wideband general-purpose sources for swept and CW microwave measurements in local or remote operation modes. It incorporates the efficiency of micro-processing control with state-of-the-art BWO oscillator to produce a high performance sweep generator system suited for either manual or automated measurements.

  • Multi-Axis Laser Interferometer

    Automated Precision Inc.

    The award-winning XD Laser is a multidimensional laser measurement system that simultaneously measures all 21 degrees of freedom including linear, angular, straightness and roll errors for rapid machine tool error assessment. Measurements Include:- Rotational accuracy- Geometric error- Angular error- Flatness- Squareness- Parallelism

  • Light Source

    LS-BA - OtO Photonics Inc.

    Balance Light Source (LS-BA) is designed for transmittance and absorbance measurement with color information. Halogen Light source provides the stable and smooth wide-band spectral output. It’s proper for most visible to near infrared range measurement. The efficiency of blue region will be enhanced by extra two blue LEDs.

  • Light Source

    LS-DH - OtO Photonics Inc.

    Deuterium-Halogen Light Source (LS-DH) is a combination of Deuterium Light source and Halogen light source. Deuterium light source is proper for UV range measurement and Halogen light source is proper for visible and near infrared region measurement. The light source output is standard SMA905 and can be attached to the fiber directly.

  • Current Probe

    DCFlex - Power Electronic Measurments Ltd

    The DCflex is an easy to use, low cost, thin and clip-around DC current probe. It is suitable for measuring large DC currents of >2kA. The DCflex takes a single shot measurement of the DC current with a typical accuracy of ±1%. It is important to understand that the DCflex does not provide a continuous measurement of DC current.

  • Moisture Analyzer

    2850 - Ametek Process Instruments

    Establishing a new standard for clean gas moisture analyzers, the 2850 provides exceptional performance, with virtually no interferences, multi-gas compatibility, and on-board measurement verification. The 2850 uses the most accurate trace moisture measurement technology available to deliver an ultrafast response to both increasing and decreasing moisture levels.

  • Fixed Terminations

    ZTS Technologies Co., Ltd

    Fixed Terminations absorb RF & microwave energy and are commonly used as dummy loads of antenna and transmitter.They are also used as match ports in many multi-port microwave device such as circulator and directional coupler to make these ports which are not involved in the measurement be terminated in their characteristic impedance in order to ensure an accurate measurement

  • UXA In-band 5G NR/MIMO OTA Testing up to 50 GHz

    N9040BM - Keysight Technologies

    The N9040BM UXA bundle solution for in-band 5G NR/MIMO OTA testing allows you to make worry-free measurements up to 50 GHz with included 5G measurement apps. Achieve a full 5G NR test setup complete with software, hardware options, and accessories for increased accuracy and precision.

  • Meters For Contact Angle And Surface Tension

    Contact Angle Standard - Optik Elektronik Gerätetechnik GmbH

    The contact angle standard is a glass plate with images, representing sessile drops with different contact angles. The contact angle standard is manufactured by a high accurate lithographic process, so the images itself are very accurate according the given CAD-data. The Glass plate is placed on the measuring table instead of a real drop. The proof of the reproducibility of the contact angle measurement is performed by a repeated measurement of the object (sessile drop). For a correct test, the measurement must be performed, using the live video (not a frozen image). For a real sessile drop exists the problem, that it evaporates permanently. The result of the permanent evaporation is the permanent change of the contact angle. Therefore, the proof of the reproducibility of the contact angle measurement is not possible, using a real liquid, since the object changes permanently the contact angle!

  • CT-PT-CVT Measuring

    Shanghai Himalayal Co.

    Testing object: S current transformer, normal current transformer, voltage transformer● Testing item: ratio error, phase error, impedance, admittance of the transformer, etc● Rated current:5A,1A ( Customized )● Rated voltage: 100V, 100/√3V, 100/3V, 110V, 110/√3V, 110/3V, 120V, 120/√3V, 120/3V, 220V (or other)● Measurement range: ratio error measurement range : 0.0001%-19.99% phase error measurement range : 0.01 ' -900 '● Error minimum resolution:ratio error:0.0001%; phase error:0.01 ' ● Communication function : provide RS232 serial communication port● Measurement accuracy: ±1%● Consumed power: less than 20VA● Dimension :460×380×160 mm● Weight: 12kg

  • Coordinate Measuring Machines

    CMM - Aberlink Ltd

    Aberlink offers a wide range of bridge and hexapod CMMs to suit all applications and budgets, enabling the precise measurement of the smallest of components to parts of over 3 metres long and up to 6 tonnes in weight with a wide range of touch-trigger probes and non-contact measurement options. The comprehensive range of CMMs includes 32 standard sizes of both CNC and manual variants. All CMMs are supplied as a complete turnkey package including the Aberlink 3D measurement software, the easiest to use and most intuitive CMM software currently available.

  • Digital Absolute Pressure Meter

    Model KM 8070 - Kusam Electrical Industries Limited

    KM 8070 is an absolute pressure measuring instrument with 8 units (Pa, hPa, mbar, mmH2O, mmhg, inHG, in H2O, psi). It is normally used to measure absolute pressure, e.g. for pressure compensation in velocity measurement in ducts, laboratories and production processes. Barometric measurement and height measurements between two points are also possible. With hold, MAX, MIN, and AVG function, KM 8080 is widely used in HVAC, Laboratories and architecture project. With our reputation for quality products, you can find it is the most economic instruments for pressure meter.

  • Multifunction I/O Device

    NI

    The Multifunction I/O Device features I/O with varying channels, sample rates, output rates, and other features to meet many common measurement requirements. You can use the device for industry applications such as laboratory automation, research, and design verification. The included DAQExpress companion software provides basic measurement and analysis, while the included NI-DAQmx driver provides the ability to create customized automated measurement and control applications. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.

  • Precision High Voltage Meter

    Vitrek Corporation

    Precision High Voltage Meter offers the highest level of measurement accuracy, yet with its color touch screen – is surprisingly easy to use. Vitrek leverages DSP technology to provide outstanding AC &DC voltage measurement accuracy, stability, repeatability and resolution. The 4700 High Voltage Meter offers performance that rivals traditional high voltage reference dividers – yet unlike the tedious divider, the 4700 provides instant, direct, high voltage measurements in a highly portable, compact and rugged bench top enclosure.

  • Spectrophotometers

    EssentOptics Ltd.

    The PHOTON RT UV-VIS-MWIR research spectrophotometers from EssentOptics are convenient and reliable instruments for a broad range of optical measurement applications. You''''ll always enjoy working with them, trusting their functionality and accuracy.The PHOTON RT UV-VIS-MWIR Universal Scanning Spectrophotometers is a powerful multi-purpose instruments designed for coaters. It offeres incomparably greater advantages when compared with the traditional tools offering unattended measurement of optical thin film coatings including variable angle and polarization-dependent measurements without any attachements.

Get Help