Showing results: 2881 - 2895 of 10492 items found.
-
1100 Percent Oxygen -
Bacharach, Inc.
The Neutronics 1100 Percent Oxygen Analyzer is a compact analyzer for oxygen gas measurement and process control applications. Designed for a measurement range of zero to 100% oxygen, the unit features a reliable electrochemical sensor that can be mounted remotely at the sampling point to ensure a fast response time. A flow-through mounting head allows the sensor to be horizontally or vertically mounted directly into the sampled process gas stream.
-
APCIE-3021-16-3 -
TEAM SOLUTIONS, INC.
The PCI-Express analog input/output board APCIe-3121 has 16 SE/differential inputs, 8 analog outputs, 16-bit, and 8 digital I/O, 24 V. The board is especially suited for applications in industrial process control, measurement technology and monitoring, for example for multichannel data acquisition, for the control of chemical processes, for the acquisition of sensor data, current measurement etc. in the harsh industrial environment.
-
LE-PC800G -
LINEEYE Co., Ltd.
*The PC Link is software that provides an efficient measurement environment utilizing the high-resolution screen and high-capacity HDD of a PC.*The analyzer can be remotely controlled by the PC so that measurement data will be displayed on the screen or continuously recorded on the HDD.*The PC Link incorporates versatile features (e.g., a search function that finds target data exactly, a TEXT-CSV conversion function that is useful for the generation of reports, and Japanese-English display).
-
3001 -
Martel Calibrators
The Precision Lab Calibrator combines the power and features of the venerable M2001 lab calibrator, with the addition of an isolated measurement channel. This isolated measurement channel consists of two (2) voltage ranges: 10V and 100V DC, MilliAmp range 0 to 52 mA, MilliAmp range with simultaneous 24VDC power, selectable 250 Ohm HART resistor and accuracy of 0.005% of reading on voltage ranges.
-
Perma -
Giatec Scientific Inc.
Giatec Perma™ is a completely re-engineered laboratory test device for the measurement of the electrical resistance of concrete against the penetration of chloride (RCPT) according to the standard methods such as ASTM C1202, AASHTO T277 and ASTM C1760. The measurement data can be used to estimate the chloride diffusion coefficient of concrete for the service life prediction and design of concrete structures as well as the durability-based quality control of concrete.
-
(RTS) 4.0 -
Engineering Design
Real-Time Spectrogram (RTS) 4.0 provides viewing, measurement, and editing of unlimited-length sound files. RTS 4.0 operates as a module within SIGNAL 4.0, so measurement data can be stored in the SIGNAL logfile and sound segments can be exported directly to SIGNAL buffers (as well as saved to disk). Analog I/O is provided by one of the direct-to-disk analog I/O programs described below.
-
Guildline Instruments Ltd
Provides the best in measurement uncertainties for Direct Current Comparator (DCC) Resistance Bridges. Unique innovations in 6622A design and modularity means users no longer have to decide what Bridge satisfies current requirements as well as future requirements. Optional modules allow for normal, high ohms, and low ohms measurements without having to purchase multiple bridges as per competitive products.
-
KX132 (Qwiic) -
SparkFun Electronics
This SparkFun Triple-Axis Accelerometer Breakout is a simple Qwiic breakout for the KX132 digital accelerometer from Kionix. The KX132 is a low-power, 16-bit resolution three-axis accelerometer with four user-selectable acceleration measurement ranges of ±2g/4g/8g/16g and has up to a 10kHz (max) output data rate making it ideal for a wide range of acceleration measurements as well as high-speed applications such as vibration and tap sensing.
-
Expert Logger -
Delphin Technology
Expert Logger is a new generation of data loggers. It combines the latest communication technology with advanced measurement technology, and is based on FPGA technology to make it especially powerful. It can process up to 46 analog input channels at both low and high rates of sampling. Measurement data can be accurately acquired, independently stored and transmitted to the internet or a PC for evaluation via USB, LAN, WLAN or LTE.
-
Ruby -
Nerian Vision Technologies
Machine vision applications are as diverse as the 3D sensor technologies that enable those. Structured light camera systems are a preferred solution when precision is required, but neither high frame rates nor color information are needed. Stereo vision, on the other hand, is the preferred technology when measurements are to be made in daylight and/or over long measurement distances, but it has difficulties with textureless surfaces.
-
CS-100F1 Series -
HORIBA, Ltd.
The CS-100F1 Series is equipped with fiber optics cable based on the CS-100 Series. It offers real-time, in-line measurements by directly integrating the sample cell into the cleaning system piping and by using a fiber optic cable for light signal transmission. A single concentration monitor can take up to four measurements and monitoring of multiple chemical solutions in a single-bath or single-wafer cleaning system is also possible.
-
Dantec Dynamics A/S
Soot is considered a hazardous pollutant emission and is typically a result of incomplete combustion processes, and thus is also related to combustion performance. Laser Induced Incandescence (LII) is a laser-optical measurement technique dedicated to soot diagnostics. LII can provide measurements of soot volume fraction, such as in Diesel engine exhaust, and even instantaneous images of soot distribution during formation inside a running IC engine.
-
Anritsu Corporation
Choose from a family of spectrum analyzers whose measurement capabilities cover frequencies from 50 Hz to 110 GHz, with the option of extending coverage to 325 GHz with external mixing solutions.Anritsu's Spectrum Master handheld spectrum analyzers provide excellent flexibility in field environments for locating, identifying, recording, and solving communication systems problems without sacrificing measurement accuracy.
-
EM-6912A | 30 Mhz – 300 MHz -
Electro-Metrics Corp.
A balun, feedline, and element cage give the Electro-Metrics EM-6912A response curves that are almost linear, making it ideal for swept measurements. An added benefit is that the EM-6912A has an improved BALUN design, which makes it insensitive to changes of orientation while vertically polarized. Readings obtained will be the same no matter which element is closest to the ground plane, eliminating a potential source of measurement error.
-
TCB-108 -
Criterion Instruments Limited
Model TCB-108 - Capacitance Bridge is a general purpose bridge for measurement of capacitors, capacitance of transformers and dielectric material. It comprises a transformer-type bridge operating from an internal 108 Hz generator(for accurate measurement at 60Hz) with digital readout of capactiance from 1 pF to 99.999 pF over four ranges and digital readout of D (dissipation factor) in percentage from 0-50%.