Filter Results By:

Products

Applications

Manufacturers

Measurement

an acertained value.

See Also: Metrology, Instrumentation, Sensors, Meters, Stability


Showing results: 6811 - 6825 of 10492 items found.

  • Gel Strength Test System

    LD-LGST-A10 - Labodam

    Gel Strength Test SystemLD-LGST-A10is mainly used to measure the gel strength of gelatine under the stipulated environment. It has traveling accuracy ± 0.3 % and Test range up to 5 to 1000 g Bloom. It consists of Jelly Strength Tester, Constant Temperature Bath and Refrigerator. Sampling depth can be present arbitrarily in 1 to 60 mm. It consists four kinds of sampling measurement modes: single-step, maintaining, circulating and automatic.

  • Flush Diaphragm Pressure Sensors

    Honeywell Sensing & Control

    For high-frequency pressure measurements or in applications with severe space limitations, Honeywell Sensotec offers subminiature flush diaphragm pressure sensors in ranges from 0100 psi to 020,000 psi (010 to 01,400 bar). All-welded, machined stainless steel sensing diaphragms ensure ruggedness. Bonded piezoresistive and metal foil strain gauges offer high reliability. Millivolt and optional high-level outputs are compatible with most data acquisition systems.

  • High Voltage Probe: Single-Ended

    Tektronix, Inc.

    A high voltage single-ended probe is typically used for measuring ground referenced signals up to 40 kV. However, some single-ended probes are designed for oscilloscopes with isolated or floating inputs for measurements that are not ground referenced. Users should select probes with a low input capacitance specification (< 4 pF) to minimize the probe’s loading effect on the circuit because a probe with lower input capacitance will offer higher input impedance at higher frequencies.

  • VXI Chassis

    AMETEK VTI Instruments

    The first VXIbus specification was introduced to the test and measurement community in 1987 and was initially developed to provide a card-based instrumentation platform for applications that required high density and high performance. The platform continues to thrive today by leveraging off the original specifications which define the necessary physical (real estate/cooling) and electrical standards for demanding applications and has established itself as the ‘time-tested bus you can trust’ for requirements that must be supported in excess of ten-fifteen years.

  • VXI Series

    AMETEK VTI Instruments

    The first VXIbus specification was introduced to the test and measurement community in 1987 and was initially developed to provide a card-based instrumentation platform for applications that required high density and high performance. The platform continues to thrive today by leveraging off the original specifications which define the necessary physical (real estate/cooling) and electrical standards for demanding applications and has established itself as the ‘time-tested bus you can trust’ for requirements that must be supported in excess of ten-fifteen years.

  • Antenna Test Chamber

    Comtest Engineering bv

    Comtest provides Antenna test ranges fully covered with microwave absorbers for both near-field and far-field measurements. Because we always strive for new solutions, our R&D department developed our ‘Javelin Tip’ polystyrene absorbers. The enhanced material composition and altered shape, lead to improved performance and cleaner working space, enabling you to make high precision antenna testing fast, reliable, and worry-free.

  • Universal (ID/OD) Presetting Instruments

    Pratt & Whitney Measurement Systems, Inc.

    If gage setting and calibration is important to you, choose the Labmicrometer Model 900 or 1600 measuring system. Designed for gage calibration laboratories and shop floor environments requiring precise internal and external measurements over long lengths. Additionally, the Labmicrometer is ideal for use as a setting bench and adjusting instrument offering precision setting of inside and outside comparative measuring gages, micrometers, snap gauges, as well as other measuring tools.

  • Megawatt Large Display Indicator

    Signals & Systems India Private Limited

    Large display indicator measures and displays the Megawatt from inputs like 63.5VAC, 4-20mA and data received from other equipment. It meets high accuracy of 0.1% to measure Megawatt. The large display is for clear visibility of the MegaWatt reading from a long distance. It is equipped with high bright red color 7segment displays. These are commonly used in Power plants, Substations, Manufacturing units and Field environments to provide direct Megawatt measurements.

  • Diode Power Sensor

    8485D - Keysight Technologies

    Excellent SWR for reducing mismatch uncertainty Accurate calibration and traceability to US National Institute of Standards and Technology (NIST)Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters, plus the E1416A VXI and discontinued 70100A and 43X power meter Accurate average power measurements over -70 to -20 dBm Frequency range 50 MHz to 26.5 GHz

  • Noise Source, 10 MHz to 26.5 GHz, nominal ENR 15 dB

    346C - Keysight Technologies

    The Keysight 346C noise source is the ideal companion to Keysight's noise figure solutions. Since it is broadband (10 MHz to 26.5 GHz), it eliminates the necessity for several sources at different frequency bands. The low SWR of the noise source reduces a major source of measurement uncertainty; reflections of test signals. Option K01 is a coaxial noise source and features coverage from 1 to 50 GHz with a 2.4 mm coaxial connector.

  • E-Series Average Power Sensor

    E9301H - Keysight Technologies

    Measure the average power of all modulation formats Wide dynamic range power measurements from -50 dBm to +30 dBm10 MHz to 6 GHz frequency coverage for Wireless Comms formatsLow SWR for reducing mismatch uncertainty Calibration factors, linearity and temperature compensation data stored in EEPROM Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters

  • Basic Spectrum Analyzer

    N9322C - Keysight Technologies

    Quickly uncover key insights through fast, value-priced, general-purpose performance up to 7 GHz with -152 dBm DANL and 0.6 dB overall amplitude accuracy Streamlined for straightforward and efficient operation with marker demodulation, one-button optimization, and user-definable soft keys Robust measurement features for easily characterizing your product Automation and communication interface with industry standard SCPI language support and USB and LAN connectivity choices

  • Training Kits

    Keysight Technologies

    Keysight offers a variety of Training Kits designed to assist educators in quickly setting up new engineering courses and labs on topics ranging from the Internet of Things (IoT), RF circuit design, precision power measurement, and more. These training kits will provide you with ready-to-teach material for a full semester, covering 50 hours of lab sessions. Courseware integrates hands-on industry relevant experiences, and real-world applications.

  • Automotive Ethernet Compliance Solutions

    Keysight Technologies

    These automotive Ethernet electrical test software packages let you automatically execute tests and display the results in a flexible report format. In addition to the measurement data, the report provides a margin analysis that shows how closely your device passed or failed each test. The automotive Ethernet electrical compliance solutions perform a complete set of electrical tests to meet the BroadR-Reach, 100Base-T1 and/or 1000Base-T1 specifications. The following solutions are available:

  • 10-GHz Split Cylinder Resonator

    85072A - Keysight Technologies

    The Keysight 85072A 10-GHz split cylinder resonator measures permittivity and loss tangent of thin film, un-clad substrates and low loss sheet materials according to the IPC TM-650 2.5.5.13 test method. Designed for robustness and ease of use, it features precision cylinders to ensure high Q factor and loss tangent resolution. Compatible with the Keysight 85071E-300 materials measurement software, the 85072A and can be purchased separately or as part of a complete turn-key solution.