Filter Results By:

Products

Applications

Manufacturers

Measurement

an acertained value.

See Also: Metrology, Instrumentation, Sensors, Meters, Stability


Showing results: 7516 - 7530 of 10562 items found.

  • Telescopic Hot stick

    HS-178 - Standard Electric Works Co., Ltd

    ● Triangular-shaped design keeps sections aligned    during extension and retraction● Push button release for stick extension and retraction ● Telescopic design allows for easy assembly, storage     and transportation● Lower push button fix position for better support of the telescopic hot stick● Withstands voltage rating of 100kV from 30cm for  5 minutes      ● Universal end fitting accepts a wide variety of standard attachments● High-visibility yellow tip section● Easy-to-replace sections● Carrying bag included  ● Optional integrated height measurement scale● Complies with IEC 62193 safety standard

  • PXIe-5774, 12-Bit, 6.4 GS/s, DC-Coupled, 2-Channel PXI FlexRIO Digitizer

    785646-01 - NI

    The PXIe-5774 provides up to 3 GHz of DC-coupled analog bandwidth and 12 bits of resolution. You can operate the PXIe-5774 in a dual-channel mode at 3.2 GS/s or in a single-channel interleaved mode at 6.4 GS/s. The voltage ranges are software-selectable and include 200 mV peak-to-peak and 1 V peak-to-peak, with a selectable DC offset. The PXIe-5774 is ideal for time-domain measurements in areas such as scientific instrumentation, medical imaging, and particle physics. The FlexRIO driver includes support for finite acquisition, and you can implement custom algorithms and real-time signal processing on the LabVIEW-programmable Xilinx Kintex UltraScale FPGA.

  • PXIe-5774, 12-Bit, 6.4 GS/s, DC-Coupled, 2-Channel PXI FlexRIO Digitizer

    785647-01 - NI

    The PXIe-5774 provides up to 3 GHz of DC-coupled analog bandwidth and 12 bits of resolution. You can operate the PXIe-5774 in a dual-channel mode at 3.2 GS/s or in a single-channel interleaved mode at 6.4 GS/s. The voltage ranges are software-selectable and include 200 mV peak-to-peak and 1 V peak-to-peak, with a selectable DC offset. The PXIe-5774 is ideal for time-domain measurements in areas such as scientific instrumentation, medical imaging, and particle physics. The FlexRIO driver includes support for finite acquisition, and you can implement custom algorithms and real-time signal processing on the LabVIEW-programmable Xilinx Kintex UltraScale FPGA.

  • PXIe-5774, 12-Bit, 6.4 GS/s, DC-Coupled, 2-Channel PXI FlexRIO Digitizer

    785647-02 - NI

    The PXIe-5774 provides up to 3 GHz of DC-coupled analog bandwidth and 12 bits of resolution. You can operate the PXIe-5774 in a dual-channel mode at 3.2 GS/s or in a single-channel interleaved mode at 6.4 GS/s. The voltage ranges are software-selectable and include 200 mV peak-to-peak and 1 V peak-to-peak, with a selectable DC offset. The PXIe-5774 is ideal for time-domain measurements in areas such as scientific instrumentation, medical imaging, and particle physics. The FlexRIO driver includes support for finite acquisition, and you can implement custom algorithms and real-time signal processing on the LabVIEW-programmable Xilinx Kintex UltraScale FPGA.

  • PXIe-5774 , 12-Bit, 6.4 GS/s, DC-Coupled, 2-Channel PXI FlexRIO Digitizer

    785646-02 - NI

    The PXIe-5774 provides up to 3 GHz of DC-coupled analog bandwidth and 12 bits of resolution. You can operate the PXIe-5774 in a dual-channel mode at 3.2 GS/s or in a single-channel interleaved mode at 6.4 GS/s. The voltage ranges are software-selectable and include 200 mV peak-to-peak and 1 V peak-to-peak, with a selectable DC offset. The PXIe-5774 is ideal for time-domain measurements in areas such as scientific instrumentation, medical imaging, and particle physics. The FlexRIO driver includes support for finite acquisition, and you can implement custom algorithms and real-time signal processing on the LabVIEW-programmable Xilinx Kintex UltraScale FPGA.

  • Coating Thickness Tester

    Extech CG104 - Extech Instruments Corporation

    The CG104 is a pocket-sized coating thickness tester which offers quick one-handed operation and non-destructive measurements of the thickness of ferrous and non-ferrous substrates. Its unique reversible display allows you to take readings in challenging angles of area being measured, plus it has an easy-to use menu system and backlit display feature. Built-in memory stores/recalls up to 255 readings. Complete with two AAA batteries, calibration standards (one ferrous plate, one non-ferrous plate and one standard coating plate film), wrist strap and soft case.

  • Automatic Three Phase Transformer Ratio Meter

    ATRM PLUS - Eltel Industries

    *Fully Automatic measurement.*Wide selection of Excitation Voltages of 10V, 40V, 100V, 230V & 250V from front panel.*4V Excitation voltage provided for CT measurements*Ratio range of up to 5000; direct display of measured ratio.*No conversions required.*Automatic Jumper selecting as per the vector*Diagram of Transformer.*Automatic testing of all 3 phases in 3 phase transformers*Without manual intervention.*Displays % deviation from a nominal ratio.*External storage facility using pen drive.*Internal storage up to 10000 readings.*Touch screen 7” Color TFT display with backlighting with*Resolution of 800 X 480.*Tap changer facility.*Computer interface using RS-232 or USB.*Windows Interface software provided for data transfer.*USB printer interface.*Four terminal measurements to reduce errors due to*Winding and lead resistance.*Auto print and storage facility.Fast measurements.

  • DC Bias Current Power Supply

    TH1775 - Shenzhen Chuangxin Instruments Co., Ltd.

    TH1775 is a DC Bias Current Source (or DC Magnetization Current Source) used for inductance measurement of inductors and transformer windings with DC bias current. Except for constant current output, low additional error and wide frequency response range are important for bias current inductance measurement. High frequency LCR meter could be used, when the frequency response range is wide enough. MPU controlled auto current balance technology is adopted to realize AC+DC current overlap and constant current output from 0 to ±20A. Two TH1775 can be paralleled to supply a maximum current up to 40A.TH1775 permits high frequency measurement up to 1 MHz and can be directly controlled by TH2816A, TH2817A, TH2818 and TH2819. TH1773/TH1775 with its low additional error, wide frequency response range and sweep output function is widely used in DC biased inductance measurement. TH1775 also provides a perfect solution for magnetic material analysis.

  • Zero Bias Schottky Detectors

    Fairview Microwave Inc.

    Fairview Microwave’s line of coaxial packaged zero bias Schottky detectors feature matched inputs for excellent VSWR, voltage sensitivity levels that range from 100 to 500 mV/mW for small signal detection, negative video output polarity, and can withstand maximum input power levels up to +20 dBm CW. Operating temperature range covers 0°C to +90°C and storage temperature of -65°C to +125°C. These zero bias Schottky detectors utilize compact cylindrical package outlines that are made of passivated stainless steel and offer a variety of popular input/output SMA and BNC connector configurations that make them ideal for use with precision test and measurement, instrumentation, and subsystems assemblies. Numerous applications include power measurement, leveling pulsed signal sources, AM noise measurements, radar or missile guidance systems, monitoring system level performance, and pulsed RF measurements.

  • NI-9244, 400 Vrms L-N, 800 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module

    783106-01 - NI

    400 Vrms L-N, 800 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module - The NI‑9244 performs single-ended analog input. The wide measurement range makes it ideal for high-voltage measurement applications such as phasor measurements, power metering, power quality monitoring, industrial machinery, and motor test. You can also perform transient and harmonic analysis with high-speed simultaneous sampling. The NI‑9244 offers three channels, so you can connect single‑ or three‑phase measurement configurations such as WYE and delta. You can incorporate the NI‑9244 into systems to meet standards such as IEC 61010‑1, C37.90 and C37.60, IEC 60255‑22‑(1:7), IEC 60255‑1, C37.188 Class M and P, EMC section of IEC 60870, EMC sections of IEC 61850, IEC 61000‑4‑30 Class S, and IEC 61000‑4‑7.

  • Power Quality Analyzer

    PQM-707 - Sonel S.A.

    Power Quality Analyzer Sonel PQM-707 is an autonomous meter allowing for versatile measurement, analysis, and registration of energy networks parameters DC and 50/60Hz, including the quality of electric energy in accordance with the European standard EN 50160 and the Regulation of the Minister of Economy on detailed conditions of the electro-energetic system functioning. All parameters are measured in the S class of the IEC 61000-4-30 STANDARD guaranteeing high accuracy of measurements.

  • Data Interfaces, Sensors And Actuators

    Dewesoft d.o.o.

    Dewesoft also develops and manufactures data interfaces such as CAN USB devices, GNSS and INS positioning devices, and Inertial Measurement Units (IMU), and high-speed cameras. All devices are completely compatible and synchronized with all of our Data Acquisition (DAQ) systems and offer the same highest possible built quality. To complete the measurement chain we also provide high accuracy current and vibration sensors.

  • Engine Performance/Endurance Test System

    Ono Sokki

    Various types of test system as follows can be built up in combination with measurement control equipment and peripheral instruments (fuel flow meters, actuators, temperature control device, combustion analysis system, ECU monitor, OBD, sound and vibration measurement instruments, emission analyzer, smoke meter etc.)·Traveling fuel economy test·Gas emission test·Output performance test·Deterioration/endurance test·Combustion analysis·Sound source probing

  • NI LabVIEW Base Development System for Windows

    NI

    NLabVIEW is system engineering software designed for applications that require test, measurement, and control with rapid access to hardware and data insights. The LabVIEW Base Development System is recommended to integrate NI hardware and third-party devices together to build automated desktop measurement applications with an intuitive graphical programming syntax.For applications that require advanced inline analysis or PID control, consider LabVIEW Full Development System.

  • Battery Conductance Tester

    HDGC3918 - HD Power Test Equipment Co.ltd

    HDGC3918 Battery Tester with AC discharge measurement method is used to measure the voltage and Conductance of battery, which can judge the capacity and state of heath of battery .The measurement data can be read on the instrument display directly. And it can also be uploaded to PC simply by USB drive. With the analysis software, you could not only keep a record of the testing result but also have analyzed for the status of batteries in different testing conditions.

Get Help