Showing results: 1936 - 1950 of 7331 items found.
-
SX40C -
Diamond Antenna Corp.
Frequency range:144 to 470MHz. Power display range:15W 150W. Accuracy at full scale:10%AT.FS. Minimum power at SWR measurement:3W
-
SX27P -
Diamond Antenna Corp.
Frequency range:140 to 150MHz/430 to 450MHz Power display range:15W 60W. Minimum power at SWR measurement:0.1W 60W. Insertion loss:Less than 0.3dB. Measurement function:Forward Rf
-
DP-cPCI-5031 -
Data Patterns Pvt. Ltd.
DP-cPCI-5031 is a Resolver to Digital and Digital to Resolver converter module. This module has four S/R to Digital converters(measurement channels) and two Digital to S/R converter(stimulus channels). This module is programmable for simultaneous acquisition and generation of the Resolver signal.
-
IRIS Instruments
Specifically designed for very shallow, high resolution resistivity sounding and profiling, the Kid is the most compact of the Syscal range whilst retaining the well-known reliability and measurement accuracy of its counter parts.
-
NPP MERA
● Sampling rate: up to 216 kHz/channel ● Dynamic range: up to 120 dB ● Built-in charge amplifier ● Self-diagnostics ● Modular architecture ● Simple scalability ● Specialized software for registration, real-time analysis and post-processing
-
ForTest Italia Srl
The T9731 is specifically designed for measure the adequate air flow rate in complete adherence to the standard EN 14683 for surgical masks testing.Full scale from 10 mbar to 10,000 cc/minFlow measurement accuracy : 1% RDG + 0.1% FSFlow measurement resolution : 1 cc/minDirect pressure accuracy : 0,5% RDG + 3 DGTDirect pressure resolution : 0.001 mbar (0.1 Pa)
-
Shimpo Instruments
SHIMPO offers a wide range of hand-held tachometers that measure the total number of revolutions of a shaft or number of pulses of reciprocating equipment. Our models can measure and record last/min/max and up to 10 reading using up to 16 different units of measure. Our tachometers are designed for applications such as Motor Speed/Conveyor Speed/Fan Speed/Length Measurements that measure rpm of motors or shafts, either contact or non-contact with Laser style combination tachometer.
-
Shenzhen Graigar Technology Co.,Ltd.
Measurement of the speed of a rotating shaft is a common requirement in many industrial and laboratory applications. Such measurements have usually been carried out in the past with the help of contact type tachometers with friction drive. More recently digital optical non-contact tachometers have been designed which count the reflected pulses from a white patch on the shaft and then display the speed in rpm. The light source is usually a filament lamp operating with dry cells leading to limited life and illumination. A similar ideawith magnetic pick-up from a particular area of the shaft has also been used for speed measurement.
-
I-Scan® System -
Tekscan, Inc.
This versatile tactile pressure measurement system is tailor-made by choosing from over 200 pressure sensors to meet your specific application requirements.
-
TDX 5000 -
Altanova Group
TDX 5000 is developed as a compact solution for high voltage Capacitance and Tan Delta (Dissipation Factor) measurements. Using the reactor option, TDX 5000 can also perform tests on rotating machines.
-
TD Series -
b2 High Voltage
While partial discharge measurement is suitable for detecting electrical trees, tangent delta measurement – also referred to as dissipation factor measurement – detects water trees which have formed in the insulation of the device under test.
-
TD 5000 -
Altanova Group
The high-voltage generator TD 5000 is a complementary module of STS serie. TD 5000 designed to perform Tan Delta measurements, dissipation factor and capacitance of transformer and bushing at the frequency of the mains or in a wide frequency range.
-
IBEKO Power AB
Winding resistance test of inductive test objects, such as power transformers, is one of the most effective non-intrusive ways of checking its condition. Due to their advanced design, DV Power winding resistance meters provide high test currents (up to 100 A DC) and high accuracy (up to 0.1%) within light and portable test instruments. In addition to winding resistance measurement, it is also possible to perform simple, quick and reliable transformer on-load tap changer condition assessment by recording the test current during tap changer operation, also known as DVtest. Because of that, problems with a tap changer connection, contacts, and switching procedure can be detected.DV Power winding ohmmeters consist of single-phase RMO-T and three-phase TWA series. Models from the TWA series are designed for six-winding resistance measurement of power and distribution transformers, with only one single-step cable setup. As a result of reducing the total test time, it enables significant saving of time and money.Typical application areas of these instruments are high-voltage substations and industrial environments. They are intended to measure the resistance of:Transformer windingsOn-load tap changersGeneratorsElectrical motorsHigh-current bus bar jointsCable splicesWelding joints
-
BAS004 -
Larson Davis, Inc.
The BAS004* is used to simulate foot fall noise in a manner that is well controlled and reproducible so that measured results can be replicated and compared with other measurements.
-
STM-1 -
ECO-TECH
Tapping Machine Type STM-1 is intended for measurements of acoustic insulation of ceiling in buildings. The unit fulfils Annex A of ISO 140-6/7. These parts of the standard require a tapping machine as a sound source for impact noise measurements. Type STM-1 is available with an optional remote control.