Showing results: 1441 - 1455 of 7331 items found.
-
ALVI Technologies
The basic version for mobile conductivity measurement. It is a robust and intuitive portable device for routine daily measurements in laboratories and processes. Over 1,000 operating hours with a single set of batteries (4x AA).
-
I-prober 520 -
Aim-TTi
Current measurement from insulated probing of conductorSuitable for observation and measurement of current in PCB tracks, component leads and ground planesWide dynamic range of 10mA to 20A peak to peakWide bandwidth of DC to 5MHzLow noise figure equivalent to <6mA rms at full B/WSafety rated to 300V Cat II (600V Cat 1)Suitable for connection to any oscilloscopeHigh accuracy general purpose H-field probeConverts to 'closed magnetic circuit' current probe
-
Badger Meter
The Blancett positive displacement flow meter provides high measurement accuracy for fluids over a wide viscosity range. Applications include lubricants, fuels, chemicals and solvents, oils and greases. With only 2 moving parts, the positive displacement meter offers trouble free operation and long service life. The meter is bi-directional and it has an extremely large turndown ratio, up to 400:1 in some models - with full accuracy at extremely low flow rates.
-
2734 -
Acoustic Engineering
The 2734 is a compact class D power amplifier, intended for acoustical measurements in the field or laboratory. All controls and connectors are placed on the front panel, enabling you to set up the 2734 very quickly, and to operate it in horizontal or vertical position. The 2734 is built into a robust flight case making it safe and easy to carry along.
-
PW3390 -
HIOKI E.E. Corp
The PW3390 delivers 4 input channels and ±0.04% basic accuracy for power - the top instrument in its class. Achieve more precise measurements of the power and efficiency of high efficiency equipment used in power electronics. Further, a 200 kHz measurement band and flat amplitude and phase characteristics up to high frequencies enable the precise measurement of power at top frequency levels and low power factor.
-
HIOKI E.E. Corp
Current measurement option for PW6001/ 3390/ 3390-10 Wide-band DC to 3.5MHz, 50A AC/DC rated input, 0.04V/A output PW9100-03 : 3 channels PW9100-04 : 4 channels
-
Newtons4th Ltd
The N4L Power Analyzer range utilises the latest signal processing technology. Providing fast, accurate and repeatable measurement in the most demanding of applications. Whether you need to measure the efficiency of a variable speed motor drive or the losses in a transformer, N4L have a power analyzer measurement solution for you. We’ve combined years of experience in high frequency measurement instrumentation with innovative developments in analog and digital design techniques to produce a new generation of class leading precision power analyzer. Combining real-time no gap analysis with high sampling rates throughout all fundamental frequencies, the PPA series of power analyzer’s provide true wideband gapless measurements on any input waveform. All Power Analyzers are provided with a UKAS ISO17025 calibration certificate, issued by our internal UKAS Laboratory (Calibration Laboratory No. 7949)
-
TES Electrical Electronic Corp.
Communication with PC. 4000 continuity point data logger, 25 point manual data logger. True power/ apparent Power/ Power Fractor Measurement. True RMS. V,A,W cap Ind, phase indicator.
-
NMTP -
Metra Blansko a.s.
The NMTP AC power converters with two mutually independent analogous outputs serve to convert single-phase or three-phase AC power into current or voltage analog signals. The A output is used for active power measurements, the B output for reactive power measurements.
-
Gentec Electro Optics, Inc.
Get accurate measurements with fast response times with our thermopile or pyroelectric power meters. Available with various absorbers, with the highest damage thresholds you can find in their category, our power meters cover a wide range going from the nanowatts to multi-kilowatts.
-
W-IE-NE-R, Plein & Baus GmbH
CAMAC - "Computer Aided Measurement And Control" is a joint specification of the U.S. NIM and the European ESONE committees. CAMAC was introduced in 1969 by ESONE and fully defined in 1971 with the standards EUR4100 and EUR4600. It represents a complementation of the NIM standard for computer based experiment control and data acquisition / measurements.
-
W-IE-NE-R, Plein & Baus GmbH
NIM "Nuclear Instrument Module" is the oldest and simplest nuclear electronics standard. Created in 1969 with AEC report TID20893 (Dec 1969), it defines a powered bin and plug in modules. NIM is the perfect standard for small and flexible setups for high resolution measurements with analogue electronics (amplifier, high resolution analog to digital converter, timing electronics as well as for low / high voltage supplies.
-
VXI-C Size 6025 -
W-IE-NE-R, Plein & Baus GmbH
WIENER C-size VXI mainframes of the 6000 deliver highest performance and reliability. Incorporating high density & lowest noise power supply technology the 6000 VXI series is the best choice for any demanding test and measurement VXI application.
-
VXI-D size 6021 -
W-IE-NE-R, Plein & Baus GmbH
WIENER D-size VXI mainframes of the 6021 deliver highest performance and reliability. Incorporating high density & lowest noise power supply technology the 6021 VXI series is the best choice for any demanding test and measurement VXI application.
-
VXI-C Size 6021 -
W-IE-NE-R, Plein & Baus GmbH
WIENER C-size VXI mainframes of the 6021 deliver highest performance and reliability. Incorporating high density & lowest noise power supply technology the 6021 VXI series is the best choice for any demanding test and measurement VXI application.