Filter Results By:

Products

Applications

Manufacturers

Measurement

an acertained value.

See Also: Metrology, Instrumentation, Sensors, Meters, Stability


Showing results: 1636 - 1650 of 10455 items found.

  • Air Force

    Alpha 4314 AF - Valhalla Scientific Inc.

    4314AF introduces an added safety feature that prevents the possibility of having the charging adapter connected while using the instrument for measurements. A 6-pin Mil-Spec circular connector on the front panel of the 4314AF replaces the four-terminal banana jacks and the battery charger jack. Four of the front panel connector pins are used to mate with the measurement adapter cable and the other two pins are for the battery charging cable adapter. By using separate adapter cables for measurements and charging of the batteries, it ensures that the charge circuit cannot be activated at the same time as measurements are being made.

  • Dew Point

    Rotronic Measurement Solutions

    ROTRONIC Low dew point measurement simply explained. Low dew point probe. Reliable measurement of trace moisture. One probe for portable, fixed or OEM applications. Ideal for compressed air with dew point as low as -60°C; desiccant or refrigeration dryers.The low dew point probe comes with the latest AirChip4000 technology. Calculates a measurement from the average of 8,000 single points within a 2 second interval and, together with the HYGROMER® LDP-1 dew point sensor, delivers measurements of the highest quality.

  • Paramagnetic O2 Analyzer Optional CO2 Sensor

    Model T802 - Teledyne Advanced Pollution Instrumentation

    The Model T802 O2 uses the proven paramagnetic measurement principle, coupled with state of the art microprocessor technology, to provide accurate and dependable measurements of Percent-Level O2.Paramagnetic technology is non-depleting, which means that there are no consumable parts, and ensures a consistent performance over time. The selectivity of the paramagnetic measurement for oxygen means that there is little or no interference from other common background gases. The T802 offers a stable and inherently linear measurement of oxygen, making it possible to calibrate the analyzer by checking only two points. There is no requirement for a reference gas during operation.

  • Optical Time Domain Reflectometer

    Alnair Laboratories Corporation

    The FDM-OTDR encodes multiple probe pulses at different frequencies, in the same time frame that conventional C-OTDRs send out a single pulse. This frequency-division-multiplexing enables larger data acquisition in the same measurement time compared to C-OTDRs. As a result the FDM-OTDR can achieve higher dynamic range with the same measurement time, or a significantly reduced measurement time with the same dynamic range.

  • Power Meter

    TW3203R - Techwin(China) Industry Co., Ltd

    TW3203R handheld optical power meter is the oldest portable test instrment in the Techwin power meter series. It features compact size, ease-of-use and economy advantages. It can be used for absolute optical power measurements as well as for relative loss measurements of optical fibers. TW3203R is an essential test instrument in Optical Communications, CATV and other Fiber Optic measurements.

  • Scattered Light Dust Measuring Devices

    SICK Sensor Intelligence

    The reliable way to detect low dust concentrationsLight scattering by dust particles is a measurement principle that allows even very low concentrations of dust to be detected. Depending on the system-specific requirements, either forward scattering or backward scattering can be used in this context. Both measurement principles return stable and reproducible measurement results, regardless of the gas velocity, humidity, or dust particle charges.

  • Static Meters

    Electro-Tech Systems, Inc.

    ETS static meters are offer accurate detection and measurement of static electricity found in the manufacture and handling of electronic, paper, plastic, textile, food, chemical, biomedical, and pharmaceutical products. In addition, these meters are invaluable for use in computer rooms, cleanrooms, hazardous environments, hospitals, and other locations that require the measurement of electrostatic fields. Chopper-stabilized models enable measurements in ionized environments.

  • 3 3/4 Digits Self-Changing Range Digital Multimeter

    KT7202 - Ketai instrument (kunshan) Ltd.

    3 3/4 digit self-changing range digital multimeter, display reading 3999backlight function overload protectionAC/DC voltage can be measured 0~600VAC/DC current can be measured 0~10Aresistance measurement can be measured 0~40MΩcapacitance measurement can be measured 0~100μFFrequency response 40Hz~400Hztemperature measurement to 750℃duty cycle: 0.1%~99.9%continuity test and diode test

  • Gasoline Engine Tachometer

    SE-2500A - Ono Sokki

    SE-2500A is a non-contact handheld tachometer designed for gasoline engine measurement. Detection, measurement, and display parts are all in one unit and batteries are built in the unit. Moving the detector (head of the SE-2500A) close to an ignition coil can measure rotation speed at the unit of 1 r/min or 0.01 r/s. Up to 20 measurement data can be stored in the internal memory that is convenient for later checking.

  • AC Resistance Bridge

    370 - Lake Shore Cryotronics, Inc.

    The Model 370 AC Resistance Bridge is designed for precise, accurate, low noise, low excitation power AC resistance measurements. Its primary application is the measurement of resistive materials in cryogenic environments from 20 mK to 1 K. Fully integrated, the Model 370 includes features to reduce and control noise at every step of the resistance measurement process

  • Vibration Testers

    Guangzhou Amittari Instruments Co.Ltd

    The Vibration Tester can display the parameters of “Displacement”, “Velocity” and “Acceleration” simultaneously; Applied to the periodic motion measurements to detect moving mechanical imbalances and misaligned. Designed for on-site measuring various mechanical vibration, for quality control, running time and prior equipment maintenance data. Selection of high-performance accelerometers to achieve accurate, replicable measurement It has a bearing condition measurement function.

  • Data logger and Monitoring

    testo AG

    Testo offers a wide range of data loggers for long-term recording of measurement data, e.g. for climate or temperature monitoring. Data monitoring systems are recommended for integrated measurement data monitoring. The testo Saveris system offers tamper-proof data recording and WLAN technology that provides access to your measurement data anywhere and at any time on PC, smartphone, or tablet.

  • Digital MultiMeter

    12061 - Chroma Systems Solutions, Inc.

    The 12061 6½ Digital Multimeter has assorted settings for resolution, integration time and ranges that allow users to optimize the configuration of measurement speed, resolution and accuracy when in individual measurement test modes. The 12061 has built-in a high speed, low interference A/D converter with a maximum speed of 2000 rdgs/s, making it the best solution for high speed measurement.

  • High Sensitivity Vibrating Sample Magnetometer

    VSM-P7 - TOEI INDUSTRY CO, LTD.

    Quick response as well as high stability measurement in magnetization measurement sensitivity of approx. 2×10-6emu can be made possible. Small size and reasonable price upon VSM-5 series. Combination with option of gas-flow system of temperature variable unit is capable of making measurement at -50°C~200°C. Varieties of magnetic materials can be automatically measured with a plenty of software.

  • OLLI - gas detector / measuring device

    Esders GmbH

    Gas measurement & warning instrumentExplosion-proof & compact handheld gas measurement instrumentas diffusion device. It can be used for up to 5 combustible and toxicgases as well as oxygen and comes in an extremely rugged2C synthetic housing with a Li-Ion rechargeable battery.Explosion-proof measurement instrument formethane (CH4),propane (C3H8),oxygen (O2),carbon monoxide (CO),carbon dioxide (CO2),hydrogen sulfide (H2S)

Get Help