Showing results: 3691 - 3705 of 10455 items found.
-
MP0R-FP Series -
Helmut Fischer AG
Gauge with permanently connected probe for various specimen's geometries (e.g. when measuring area cannot be reached easily)Excellent repeatability precisionTwo backlit LCD displays for convenient reading of the measured values in all instrument positions, even overheadAcoustical and optical signal of a measurement capture Statistical evaluation at the push of a button: Arithmetic mean value; standard deviation of the measured values, min and max values of a measurement seriesTolerance limits for upper and lower limit valuesMemory for max. 10.000 readings
-
Epec 3610 -
Epec Oy
Epec 3610 Control Unit is a compact controller containing 22 I/O pins, all of them can be configured as input pins. Epec 3610 has an RS-232 serial port and as an assembly variant, I/O interface that is compatible with the previous Epec 2038 Control Unit. However, Epec 3610 also comes with completely new features like high-side current measurement and an internal 3-axis accelerometer, for example, for levelling purposes. Epec 3610 also has an option for accurate Pt1000 measurement.
-
SDS1000DL+ Series -
SIGLENT Technologies
SDS1000DL+ series is a dual-channel universal digital oscilloscope, available in 50 MHz, bandwidth models. It includes a 30 Kpts memory depth that helps to ensure accurate waveform resolution and to capture longer signal lengths. With its 7 inch TFT-LCD (800*480) screen, there is adequate screen space to help better see and analyze waveform details. Along with a 1 GSa/s sampling rate, the SDS1000CML+ supports 32 parameters measurements and common mathematical operations to speed up complex / repetitive measurements.
-
FPS 2700 | VP 230048 -
Maschinenbau Haldenwang GmbH & Co. KG.
The FPS 2700 roller set is used in test centres and is suitable for vehicles with a single driven axle. It was designed for the exact measurement of the exhaust gas behaviour of vehicles during their transient emission test and permits a driving resistance simulation for the exhaust gas tests ASM-5015 and ASM-2525 (Acceleration Simulation Mode) in accordance with the specifications BAR '97. As a result of the increased tractive force of its eddy current brake, the FPS 2700 is additionally suitable for power measurements at constant speed and constant tractive force.
-
FLIR CM55 -
Teledyne FLIR
The FLIR CM55 is an ergonomic tool designed to simplify difficult current measurements. Made with a narrow, 10-inch (25.4cm) flexible coil clamp, the CM55 lets you easily take measurements in tight or awkward spots— a difficult task with a traditional hard jaw clamp. With Bluetooth® communication for remote viewing and data transfer to iOS® and Android™ devices via the FLIR Tools Mobile app, you can analyze and share data fast right from the jobsite.
-
EverBeing Int'l Corp
Everbeing offers GGB’s high impedance active probe for failure analysis of your devices. The high impedance with low capacitive design allows measurements of internal nodes without loading the device. For more information, please visit http://www.ggb.com.Everbeing offers GGB’s high impedance active probe for failure analysis of your devices. The high impedance with low capacitive design allows measurements of internal nodes without loading the device. For more information, please visit http://www.ggb.com.
-
OMM-6810B -
Newport Electronics
The OMM-6810B is a power and wavelength meter capable of simultaneously measuring the optical power and wavelength of a laser source. A wide variety of measurement heads cover wavelength ranges from 350 to 1650 nm for power ranges of up to +40dBm or 10W.This meter has standard features such as logarithmic or linear display modes, auto ranging, user calibratable offset, reference measurement capability, analog output and IEEE-standard GPIB interface to make this instrument a cost effective laser diode development or production test tool.
-
Beamex Oy Ab
We offer pressure calibrators as portable and as workshop models. Pressure measurement is performed with internal and/or external pressure modules for better flexibility. Pressure measurement ranges go from vacuum up to 1000 bar (14,500 Psi). Both gauge (vacuum and positive) and absolute pressure can be measured with same modules meaning you don’t need to buy so many module for greater flexibility. Also, intrinsically safe pressure calibrators are available for use in hazardous areas.
-
COCLA -
F. W. Breithaupt & Sohn GmbH & Co.KG
*Measurement and reading of azimuth of dip and angle of dip in one single operation (according to Clar method)*Declination (± 30°) and inclination adjustable*Automatic arresting of needle when not in use*Eddy current damping allows reading after approx. 3 sec.*Transparent circle with diameter 50mm with interval of graduation 1°*Dip measurement range 270° graduated in 5°Reading by estimation 1°*Deep etched tracing edge graduated (60mm)*Circular spirit level (observable also from underneath)
-
MR176-KIT6 -
Teledyne FLIR
Gain a competitive advantage with the advanced, affordable inspection tools in the FLIR MR176-KIT6. This kit includes the MR176, a powerful moisture meter with the flexibility to take either intrusive or non-intrusive measurements, and the E6, the ultimate thermal inspection tool for building, electrical, and mechanical applications. Easy-to-use, rugged, and field-ready, both tools are designed to help you find problems faster and give you that competitive edge. The kit also comes with a hammer/wall cavity probe combo for additional moisture measurement applications.
-
521 -
ACO Pacific, Inc.
Accepted internationally 1 kHz represents the "0 dB" reference point of A, B, C Weighting and other filters utilized in acoustic measurement. The Pistonphone - a mechanical sound source - offers a slightly higher degree of accuracy at a substantial increase in cost. In addition, the 200 or 250 Hz operating frequency is mechanically limited and not suited for measurements of filtered inputs. The 0.2 dB accuracy is quickly lost in the 0.7 to 1.5 dB tolerances acceptable for weighting filters at frequencies around 250 Hz.
-
511E -
ACO Pacific, Inc.
Accepted internationally 1 kHz represents the "0 dB" reference point of A, B, C Weighting and other filters utilized in acoustic measurement. The Pistonphone - a mechanical sound source - offers a slightly higher degree of accuracy at a substantial increase in cost. In addition, the 200 or 250 Hz operating frequency is mechanically limited and not suited for measurements of filtered inputs. The 0.2 dB accuracy is quickly lost in the 0.7 to 1.5 dB tolerances acceptable for weighting filters at frequencies around 250 Hz.
-
SphereOptics GmbH
Versatile, miniaturised spectroradiometer with the ability to measure both spectral radiance (luminance in cd/m²) and spectral irradiance (illuminance in lux) in one instrumentSpecbos models provide for measurements in the 250-1000 nm range, with specialist versions available for flash photometry and average LED intensity in accordance with CIE 127:2007A built-in red laser pointing device conveniently defines the measurement spot for luminance measurementsThe large variety of accessories and the UV option make this small instrument to a versatile all-rounder to fit a lot of applications
-
Virtins Technology
Digiducer 333D01 USB digital accelerometer is the first fully integrated and ruggedized packaging of a high-resolution, broad-frequency piezoelectric accelerometer with integrated internal digital data acquisition. When used in conjunction with Multi-Instrument® software, the setup allows you to take reliable and quality vibration measurements as simply as plug & play. No external power supply, data acquisition hardware, driver installation and manual entry of sensor sensitivity are required. It is a truly hassle-free portable vibration test & measurement solution.
-
19036 -
Chroma ATE Inc.
Chroma 19036 is the industry's first wound component electrical safety test (EST) analyzer that combines the functions of impulse test, hipot, insulation resistance and DC resistance measurements. It has 5kVac/ 6kVdc high voltage output, 5kV insulation resistance, 6kV layer short impulse voltage and 4-wire DC resistance measurement that can comply with the wound components test demands by providing maximum 10 channels output for multichannel scanning tests to save time and labor costs.