Showing results: 4021 - 4035 of 10456 items found.
-
LCMS-8050 -
Shimadzu Corp.
Thanks to a heated ESI probe and the UFsweeper III collision cell, the LCMS-8050 achieves a level of sensitivity 30 times that of the LCMS-8030.The UF Technology, the ultrafast measurement technology built into the LCMS-2020 has further evolved, so measurements can now be performed even faster, without sacrificing data quality. At the same time, more compounds can now be measured in simultaneous qualitative and quantitative analysis. The system can be used in a wide range of fields for a variety of applications, such as quantitative analysis which requires high sensitivity, multicomponent simultaneous analysis, and screening.
-
ISO-CART-85 -
ORTEC
Complete In-situ NDA Gamma-Ray Analysis Solutions for a Wide Variety of Samples including "Free-Release" Decommissioning WasteMeasures all common geometries: pipes, cylinders, floors, ceilings, walls, drums, boxes, and soilsEasy-roll cart for maneuvering over any surfaceWide selection of collimators and shields available for different measurement situationsContinuous height adjustment and variable tilt adjustmentISOTOPIC software, proven results on thousands of real-world samplesFactory pre-calibrated or calibrate with a single inexpensive mixed isotope point sourceFlexible reporting: measurement results can be reported in grams or activity (Bq or Ci)
-
ESR70 -
Peak Electronic Design Ltd.
The Atlas ESR provides instant measurement of a capacitor's ESR and it's capacitance value. Using the supplied gold plated probes (removable), the Atlas ESR can measure ESR down to a resolution of 0.01 ohms, up to 40 ohms. It can even measure ESR for capacitors that are in-circuit. Measurements are made at the industry standard frequency of 100kHz. Probes are now removable, allowing 2mm compatible probes to be fitted. Audible alerts are produced for various ESR levels allowing you to perform many tests in succession without having to look at the display.
-
781887-01 -
NI
Connects measurement and signal generation devices. Model options include industry-standard coaxial connector types including BNC, SMA, SMB, and MCX. Long cables can act as antennae picking up extra noise that can affect measurements, so ensure you select only the length required for your test system. Also look at the impedance of your test system and consider buying a cable with the same impedance. Matched impedance can maximize the power transfer or minimize signal reflection from the load of your system.
-
782603-01 -
NI
8 AI (10 kS/s), 4 DIO USB Multifunction I/O Device - The USB‑6000 is a low-cost, multifunction DAQ device. It offers analog I/O, digital I/O, and a 32-bit counter. The USB‑6000 provides basic functionality for applications such as simple data logging, portable measurements, and academic lab experiments. The device features a lightweight mechanical enclosure and is bus powered for easy portability. You can easily connect sensors and signals to the USB-6000 with screw-terminal connectivity. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.
-
782602-01 -
NI
8 AI (10 kS/s), 4 DIO USB Multifunction I/O Device - The USB‑6000 is a low-cost, multifunction DAQ device. It offers analog I/O, digital I/O, and a 32-bit counter. The USB‑6000 provides basic functionality for applications such as simple data logging, portable measurements, and academic lab experiments. The device features a lightweight mechanical enclosure and is bus powered for easy portability. You can easily connect sensors and signals to the USB-6000 with screw-terminal connectivity. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.
-
PCE Instruments
Lux meters are used for measuring brightness in lux, fc or cd/m². Some lux meters are equipped with an internal memory or data logger to record and save measurements. The measurement of light intensity with a lux meter is becoming increasingly important in the workplace due to safety concerns. PCE Instruments' lux meters with data loggers are highly regarded in the industry due to the devices' cosine correction of the angle of incident light.Many lux meters include software for detailed analysis and offer different interfaces for transferring measured data to a computer.
-
Process Sensing Technologies
When you buy a measurement instrument or a sensor from a PST brand we will offer you a complete solution. PST engineering services have been helping customers around the world to deliver the right product configuration for the most challenging applications. Our experienced engineers can help you with gas pipe design, analyzer cabinet design or will design the entire gas sampling and conditioning system for your measurement product. If you are an OEM customer we offer product customisation to exactly meet the required specification of your product.
-
DSOV134A -
Keysight Technologies
13 GHz analog bandwidth (upgradable)4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with low noise floor (1.09 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
DSAV084A -
Keysight Technologies
8 GHz analog bandwidth (upgradable)4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (1.04 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
DSOV204A -
Keysight Technologies
20 GHz analog bandwidth (upgradable)4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (1.54 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
DSAV334A -
Keysight Technologies
33 GHz analog bandwidth4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (2.09 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
DSAV254A -
Keysight Technologies
25 GHz analog bandwidth (upgradable)4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (1.73 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
DSOV164A -
Keysight Technologies
16 GHz analog bandwidth (upgradable)4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with low noise floor (1.32 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
DSOV084A -
Keysight Technologies
8 GHz analog bandwidth (upgradable)4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with low noise floor (1.04 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)