Filter Results By:

Products

Applications

Manufacturers

Measurement

an acertained value.

See Also: Metrology, Instrumentation, Sensors, Meters, Stability


Showing results: 5686 - 5700 of 10455 items found.

  • DC Resistance or Conductance of Insulating Materials

    ASTM D257 - National Technical Systems

    These test methods cover direct-current procedures for the measurement of dc insulation resistance,volume resistance, and surface resistance. From such measurements and the geometric dimensions of specimen and electrodes, both volume and surface resistivity of electrical insulating materials can be calculated, as well as the corresponding conductances and conductivities. These test methods are not suitable for use in measuring the electrical resistance/conductance of moderately conductive materials. Use Test Method D4496 to evaluate such materials. This standard describes several general alternative methodologies for measuring resistance (or conductance). Specific materials can be tested most appropriately by using standard ASTM test methods applicable to the specific material that define both voltage stress limits and finite electrification times as well as specimen configuration and electrode geometry. These individual specific test methodologies would be better able to define the precision and bias for the determination.

  • MSX® Thermal Camera

    FLIR TG165-X - Teledyne FLIR

    The FLIR TG165-X helps you visualize the hot and cold spots that can indicate electrical faults, mechanical break-downs, or air and water leaks. This all-in-one, non-contact measurement and imaging tool displays temperature anomalies on screen, allowing you to inspect efficiently and pinpoint the source of problems faster than with a single-spot IR thermometer. See components clearly and even read labels thanks to FLIR patented MSX image enhancement, which adds visual details to full thermal images. The bullseye laser ensures you’re always targeting the right component for measurement while easy-to-use buttons and settings help you complete the job quickly and stress-free. With internal storage for up to 50,000 images and a rechargeable Li-ion battery, the FLIR TG165-X is ready to go right out of the box.

  • Oxygen Sensor

    O2 - Bacharach, Inc.

    The O2 sensor is used in Bacharach portable combustion analyzers to measure the percentage content of oxygen levels in flue gases. The range of the oxygen sensor is 0 – 20.9%. O2 measurement is used in conjunction with the chosen fuel to calculate the CO2 levels in flue gases. Bacharach portable combustion analyzers only calculate CO2 when oxygen levels are below 16%. Bacharach uses O2 and other readings in determining efficiency rather than CO2 for a more accurate measurement. Measuring oxygen content in the excess air lets you know if you have too much air or too much fuel, allowing you to tune your furnace or boiler to maximum efficiency. Measuring O2 directly can save fuel, and save time during a combustion tune-up test.

  • Multi-Channel Anemometer

    1550/1560 Series - KANOMAX USA, Inc.

    Kanomax Multi-Channel Anemometers are research-grade airflow measuring instruments designed for high performance and precision. When coupled with our highly accurate probes this four-channel anemometer provides highly accurate and reliable data readings. It features a LCD display that displays the data from each channel. The Our 1550 & 1560 models house module bays for the connection of up to 24 channels (model 1560) or 64 channels (model 1550) of simultaneous air velocity measurements. Each bay accepts one of five unique modules allowing for a wide variety of custom configurations for air velocity, temperature, and humidity measurement. For a larger system, you can connect up to 5 units in a cascade for up to 320 air velocity channels and transfer the data to your company computer.

  • Filters & Attenuators

    ROM-Elektronik GmbH

    Attenuators are used to extend the measuring ranges of our high-frequency measuring devices HFA-3, HFR-4 and Frequency Master IV. They are suitable for measuring higher levels.The measuring range of our high-frequency measuring devices HFA-3, HFR-4 and Frequency Master IV can be adjusted upwards using external attenuators. Available attenuators are 10 dB and 20 dB. The 10 dB attenuator extends the measurement range upwards by a factor of 10 (10x higher radiation level) and the 20 dB attenuator extends the measurement range upwards by a factor of 100 (100x higher radiation level). The attenuators are simply screwed between the antenna and the measuring device.In addition to our high-frequency filter MFF-1, there are also special filters that cover frequency ranges that the MFF-1 does not. Please ask us about your special requirements.

  • Flatness, Bow, Warp, Curvature, Glass Thickness

    1D-glass Thickness Profile Measuring Instrument GPM2 - Optik Elektronik Gerätetechnik GmbH

    Highly accurate automatic measurement of glass thickness distributions. The glass thickness profiler GPM has the function to execute a fast and precise determination of the thickness profile of flat glass samples or another transparent material with a thickness range from 30µm to 700µm (option with sensor type 1) and width to 1200mm. The measuring point distance of the profile measurement can be varied over a micro-step-controlled positioning steering between 0.1mm and 1mm. The measured value accommodation for a scanning point takes place with the help of a special hardware module for image processing algorithms within 40 ms. The entire measuring time for a sample results thus as product from the sample width which has to be measured, the measuring point distance and the measuring time per measuring point.

  • Fluxmeter

    480 - Oersted Technology

    The Model 480 is a laboratory grade fluxmeter, for use with a Helmholtz coil or custom search coils. This instrument measures the total flux of a magnet part, which can be related to the magnetic field strength. Applications include magnet testing, magnetizing, and automated field measurement. In order to provide accurate and repeatable measurements, automatic or manual drift compensation is available to the user. A peak mode allows even the fastest magnetic pulse, such as those from a magnetizer, to be accurately measured. The Model 480 is also useful for measuring AC fields that are too high in frequency for a gaussmeter to detect. Relay outputs and an external reset input allow for simple automation functions to be implemented, while the RS232C and IEEE-488 ports permit advanced control of the fluxmeter via a remote computer or automation equipment.

  • Vertical Measuring Projector

    Sinowon Innovation Metrology Manufacture Ltd.

    ◆ The lifting system adopts cross roller rail and precision screw drive, which makes lifting drive more comfortable and stable;◆ Coating process reflector, clearer image and great dustproof;◆ Adjustable contour and surface illumination, to meet with difference workpiece demand;◆ Imported high light and long using life LED illumination ,to ensure precision measurement demand;◆ High resolution optical system with clear image and magnification error is less than 0.08%;◆ Powerful Bi-axial fan cooling system,highly increase using life;◆ Powerful and colorful DRO DP400,realized fast and accurate 2D Measurement;◆ Built-in Mini-printer, can print and save data;◆ With standard 10X objective, optional 5X,20X,50X,100X objective,rotary table, foot switch ,clamp, etc.

  • Scanning Mobility Particle Sizer Spectrometer

    3938 - TSI Inc.

    TSI''s newest Scanning Mobility Particle Sizer SMPS™ spectrometer is widely used as the standard for measuring airborne particle size distributions. This system is also routinely used to make accurate nanoparticle size measurements of particles suspended in liquids. The National Institute of Standards and Technology (NIST) uses a TSI DMA to size 60 nm and 100 nm standard size reference materials. SMPS spectrometer sizing is a discreet technique in which number concentrations are measured directly without assuming the shape of the particle size distribution. The method is independent of the refractive index of the particle or fluid, and has a high degree of absolute sizing accuracy and measurement repeatability. TSI''s Model 3938 is the 3rd generation of SMP, trusted by researchers for over 30 years.

  • Milliohm Meter

    16502 - Chroma Systems Solutions, Inc.

    Basic accuracy : 0.05%Pulsed test current output mode is used to reduce thermal EMFs affection on milliohm measurementDC test current output mode is used to fasten measurement speed for inductive DUTDry-circuit test current output mode (limited Max. 20mV) is used to measure such contact resistances where the maximum open-circuit voltage must be limited to 50mVTemperature correction (TC function) regardless of material or temperatureUseful temperature conversion function for motor/ coil evaluation4 channels R scan with balance check function for fan motor (combined with A165017 option)0.001mΩ~1.9999MΩ wide measurement range with 4½ digits resolutionStandard RS-232 interfaceOptional GPIB & Handler interfaceBin-sorting functionComparator and pass/fail alarming beeper functionLarge LCD display (240 x 64 dot-matrix)Friendly user interface

  • PXI Switch - 24-CH 2-Wire Multiplexer Module

    PXI-7921 - ADLINK Technology Inc.

    ADLINK PXI-7921 is a relay multiplexer which consists of 24 2-wire relays (DPDT, 2 Form C). As a multiplexer, the PXI-7921 provides 48x1 1-wire, 24x1 2-wire and 12x1 4-wire configurations. Users could choose one of the configurations by software. PXI-7921 typically connects one instrument, such as a DMM, a digitizer or a signal source, with many points which need measurement or excitation. The contact position of the relays can be changed either by direct software commands or by following the instructions previously stored in the on-board scan list. The scan list advances upon the trigger from external measurement devices, such as a DMM. The scan list could also advance when the scan-delay timer expires. In the PXI-7921, PXI trigger functions are supported and software programmable. Multiple modules can therefore be synchronized without additional field wiring.

  • Horizontal Profile Projector

    Sinowon Innovation Metrology Manufacture Ltd.

    ◆ The lifting system adopts cross roller rail and precision screw drive, which makes lifting drive more comfortable and stable;◆ Coating process reflector, clearer image and great dustproof;◆ Adjustable contour and surface illumination, to meet with difference workpiece demand;◆ Imported high light and long using life LED illumination ,to ensure precision measurement demand;◆ High resolution optical system with clear image and magnification error is less than 0.08%;◆ Powerful Bi-axial fan cooling system,highly increase using life;◆ Powerful and colorful DRO DP400,realized fast and accurate 2D Measurement;◆ Built-in Mini-printer, can print and save data;◆ With standard 10X objective, optional 5X,20X,50X,100X objective,rotary table, foot switch ,clamp, etc.

  • Counter Electrodes

    ALS Co., Ltd

    For a system using a three-electrode potentiostat, we measured current when a potential is applied between the working electrode and the reference electrode. Passage of current through an electrical circuit requires electron transfer reaction between the working electrode and the counter electrode.The main function of the counter electrode is to provide the location of the second electron transfer reaction. Important parameter of the counter electrode is the surface area. It is required (area) large enough to support the current generated for the working electrode. For example, the surface area of the platinum electrode of 5 cm is sufficient to use as an electrode, such as steady-state cyclic voltammetry experiments. However, for generating a high current measurements such as bulk electrolysis, the counter electrode of a larger area is required, as Catalog No.012961 which the length of platinum is 23 cm. This electrode is used for measurement, such as rotating ring disk.

  • TCS Comfort

    Maschinenbau Haldenwang GmbH & Co. KG.

    Trip distance / tachograph meter integrated into the brake tester (only in conjunction with PC)Electronic control unit TCS shockproof (workshop-oriented) aluminum housing with connection D-Sub 25p / D-Sub 9pEntire operation via integrated time and data display, and your existing PC (OS: Windows).Complete measurement and programming of the tachograph types 1311, 1314, 1318, 8400, FTCO 1319 MTCO 1324, TVI 2400, SE 5000, EFAs, SmarTach, DTCO 1381 incl. Integrated dial measurementLCD 4 rows, 16 digits; backlit with an integrated smart card readerMobile and / or stationary usable instrument; used stationary as integrated into the brake tester and the computer; optionally a road measurement is possible.Expression of complete test reportData storage for customer and vehicle datamultilingualism

  • PXIe-4309 , 28-Bit, 32-Channel, 2 MS/s, ±15 V Flexible Resolution PXI Analog Input Module

    784471-01 - NI

    28-Bit, 32-Channel, 2 MS/s, ±15 V Flexible Resolution PXI Analog Input Module—The PXIe-4309 samples up to 32 differential channels and multiplexes the analog input channels across eight simultaneously sampling ADCs. The module samples eight input channels up to 2 MS/s/ch (single channel per ADC), and 32 input channels up to 100 kS/s/ch (four channels per ADC). The module's flexible resolution ranges from 18 bits at 2 MS/s/ch to 28 bits at 2 S/s/ch. The module features on-board signal averaging and filtering, auto-zero measurement switching, and a chopping mode that uses a pair of channels to provide high levels of noise rejection and to enable accurate and repeatable nano-volt measurements.

Get Help