Filter Results By:

Products

Applications

Manufacturers

Measurement

an acertained value.

See Also: Metrology, Instrumentation, Sensors, Meters, Stability


Showing results: 7861 - 7875 of 10455 items found.

  • CableEye Tester Calibration Verification Board | Cable & Harness Tester

    CB50 - CAMI Research Inc. (CableEye®)

    Populated with precision resistors, it allows users to determine empirically whether the tester requires calibration. The CB50 may be used on all CableEye models. The CB50 is intended for periodic verification of tester calibration. To ensure that resistance measurements remain accurate, CAMI recommends yearly calibration. However, depending on environmental conditions and usage, testers may need calibrating more or less frequently. Certain components within models M3U, M3UH, HVX, and HVX-21 (i.e. those capable of measuring resistance) are analog components whose characteristics change slightly over time. This aging is a natural phenomenon common to all electronic components and may cause resistance measurements or gradually deviate from normal. A tester that is out of calibration will give inaccurate results. Some (maybe all) resistance measurements will be incorrect. Consequently, it may Pass what should Fail and, conversely, Fail what should Pass. In other words product yield will be contaminated due to unreliable quality.

  • Broadband Antenna

    Vivaldi - DVTest Inc.

    The dbDIRECT Broadband Antenna features a broad frequency range of operation, high gain, small form factor and directional radiation pattern, making it highly attractive for widespread use in test and measurement of emerging wireless technology devices and radars. Contrary to conventional Vivaldi antennas limited to operating only at higher frequencies, the dbDIRECT Broadband Antenna design is optimized to operate at a frequency as low as 700 MHz up to 6 GHz. This lightweight and compact antenna design provides excellent matching over a broad frequency range.The antenna is designed to be placed in a DVTEST's portable anechoic chamber such as the dbSAFE enclosures for OTA (Over the Air) testing of DUTs. The antennas can be mounted in fixed positions to facilitate repeatable results. When used in conjunction with a rotary positioning mechanism, customers are able to detect the highest point of power sensitivity for enhanced accuracy and repeatability in measurements. In this configuration, both the antennas and DUTs can be positioned in order to facilitate the measurement.

  • High Voltage 50 Ω Pulse Generator

    TLP-3010C - High Power Pulse Instruments GmbH

    *Wafer and package level TLP/VF-TLP/HMM testing*Ultra fast 50 Ω high voltage pulse output with typical 100 ps rise time*Built-in HMM (IEC 61000-4-2) pulse up to ±8 kV*High pulse output current up to ±30 A*High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)*6 programmable pulse rise times: 100 ps to 50 ns*8 programmable pulse widths: 1 ns to 100 ns*Optional pulse width extender increases pulse width up to 1.6 µs in 68 programmable steps*Fast measurement time, typically 0.2 s per pulse including one-point DC measurement between pulses*Efficient software for system control and waveform data management*The software can control automatic probers for fast measurement of complete wafers*High performance and high quality components

  • High Voltage 50 Ω Pulse Generator

    TLP-4010C - High Power Pulse Instruments GmbH

    *Wafer and package level TLP/VF-TLP/HMM testing*Ultra fast 50 Ω high voltage pulse output with typical 100 ps rise time*Built-in HMM (IEC 61000-4-2) pulse up to ±10 kV*High pulse output current up to ±40 A*High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)*6 programmable pulse rise times: 100 ps to 50 ns*8 programmable pulse widths: 1 ns to 100 ns*Optional pulse width extender increases pulse width up to 1.6 µs in 68 programmable steps*Fast measurement time, typically 0.2 s per pulse including one-point DC measurement between pulses*Efficient software for system control and waveform data management*The software can control automatic probers for fast measurement of complete wafers*High performance and high quality components

  • Field Strength Meter

    FIM-71 VHF - Potomac Instruments, Inc.

    The Model FIM-71 is a portable, laboratory quality Field Strength Meter designed for rigorous field applications. Combining a calibrated half-wave dipole antenna and a highly accurate tuned voltmeter with a range of 140 dB, the FIM-71 is suitable for practically all types of RF emission measurements in the 45 MHz to 225 MHz spectrum. The operator can switch select wide or narrow bandwidth, peak or average value of TV or pulse modulated signals, AM or FM demodulation, and a meter dynamic range of either 20 dB or 60 dB. A dc analog output voltage, proportional to the meter indication, is provided for driving a chart recorder. A leveled output from the calibrating oscillator is available for measuring cable insertion loss, filter response, amplifier gain, and other signal ratio measurements. The 4-1/2 inch, taut band, mirrored scale meter is calibrated in volts and dB for precise measurements in field or laboratory environments.

  • Field Strength Meter

    FIM-72A UHF - Potomac Instruments, Inc.

    The Model FIM-72A is a portable, laboratory quality Field Strength Meter designed for rigorous field applications. Combining a calibrated half-wave dipole antenna and a highly accurate tuned voltmeter with a range of 140 dB, the FIM-72A is suitable for practically all types of RF emission measurements in the 450 MHz to 960 MHz spectrum. The operator can switch select wide or narrow bandwidth, peak or average value of TV or pulse modulated signals, AM or FM demodulation, and meter dynamic range of either 20 dB or 60 dB. A dc analog voltage, proportional to meter indication, is provided for driving a chart recorder or similar device. A leveled output from the calibrating generator is available for measuring cable insertion loss, filter response, amplifier gain, VSWR, and other signal ratio measurements. The 4-1/2 inch, taut band, mirrored scale meter is calibrated in volts and dB for precise measurements in field or laboratory environments.

  • Power modules

    G.R.A.S. Sound & Vibration A/S

    It provides polarization voltage for the transducer, ensuring that the microphone gets the charging voltage it needs.It provides supply voltage for the microphone preamplifier. The preamplifier acts as a unity gain impedance converter. It provides a certain amount of line drive capability by providing a low output impedance and output current, making it possible to transmit the signal from the transducer to the Power Module without significant degradation.A power module can provide amplification or attenuation to the signal, thus making it possible to fine tune the measurement chain to the signals being measured and the hardware being used.Selectable filters make it possible to exclude unwanted noise from the measurement, e.g. wind induced noise from outdoor measurements.Overload detection makes it possible to validate the measurements and is a useful tool in monitoring setups.When a Power Module with gain is used, you can use longer cables because of the power module's ability to deliver current.A Power module introduces electrical isolation

  • PSD Signal Processing Tool

    SEEPOS - SiTek Electro Optics AB

    For most position measurement applications the SiTek SEEPOS system offers a complete and easy-to-use solution. High speed PSD electronics combined with digital signal processing and high speed USB data transfer gives a powerful measurement system. With its large dynamic range it can handle light powers from nW to mW from DC light sources as well as modulated light sources. All parameters, such as PSD bias voltage, amplifier gain, the use of analog and digital filters etc., are easily controlled from the included software and light spot position is continuously displayed both in XY and X-t, Y-t graphs. Optimized plot algorithms ensure that all data is visually seen on the screen even in full speed measurements. Included tools for data analysis and visualization simplify rapid scan through large data sets in order to find specific parts of interest.

  • Harmonic/Flicker Analyzer for IEC61000-3-2/3/11/12, IEC61000-4/7/15

    KHA3000 - Kikusui Electronics Corp.

    KHA3000, in addition to the complied standards and features of the KHA1000 (dedicated for single phase), is equipped for the harmonic and flicker compliance test exceeding 16A of the single-phase and three-phase equipment. With this unit alone, you can take highly accurate simultaneous three-phase measurements up to 40A/phase*. Furthermore, the KHA series is compliant with two measurement technique standards, the existing and the latest versions, so you can simply select to take measurements for the latest standard including interharmonics and for the conventional integral multiple harmonics without using any other device. In addition to the real-time display that can be used like an oscilloscope and FFT analyzer, the unit offers the real-time judgment of compliance with standards. Using this unit alone, you can judge test results and prepare result reports without the use of a PC. On top of that, you can easily set up a test system by combining KHA3000 with an AC power supply (PCR-LA Series) and a line impedance network (LIN40MA-PCR-L).

  • Moisture Meters

    PCE Instruments

    Moisture can be found in any material. Even materials considered to be dry have a minor amount of moisture. An imbalance of moisture, whether it be excessive moisture or too little moisture, can cause problems ranging from undesired mold and bacteria growth to cracks and defects. To avoid a moisture imbalance, it is essential to monitor moisture content with a moisture meter that returns accurate and reliable measuring results. A moisture meter can measure the moisture content of everything from the air (relative humidity) to construction and building materials (concrete, wood) to biomass and agricultural products (hay, straw, grain, corn, beans, pellets) to solid waste (pulp, slurry) and beyond. Many moisture meter devices can also measure temperature. The moisture measurement range of each moisture meter varies depending on the model. Some moisture meter products take moisture measurements, store the moisture measurement data to an internal memory or SD cad, and allow the stored moisture measurement data to be transferred to a computer for detailed analysis by means of an evaluation software. PCE Instruments' moisture meter products come factory calibrated. ISO calibration certificates are available optionally for purchase as accessories to most moisture meter models. An ISO calibration certificate may be important to your company in meeting specific quality standards.

  • Sound Level Indicators

    PCE Instruments

    A sound level meter is a measuring instrument used to assess noise or sound levels by measuring sound pressure. Often referred to as a sound pressure level (SPL) meter, decibel (dB) meter, noise meter or noise dosimeter, a sound level meter uses a microphone to capture sound. The sound is then evaluated within the sound level meter and acoustic measurement values are shown on the display of the sound level meter. The most common unit of acoustic measurement for sound is the decibel (dB); however, some sound level meter devices also determine the equivalent continuous sound level (Leq) and other acoustic parameters. With a portable sound level meter, industrial hygiene and workplace safety professionals can measure sound levels in multiple locations to ensure environmental conditions fall within recommended exposure limits (RELs). Some sound level meter devices can be permanently installed for continuous monitoring of sound levels at a work or job site.An important attribute to consider when searching for a suitable sound level meter is its type or class. The type or class of a sound level meter defines the device's accuracy as per American National Standards Institute (ANSI) or International Electrotechnical Commission (IEC) guidelines. Typically, "type" is the grade according to the ANSI S1.4 standard, whereas "class" is the grade according to the IEC 61672 standard. There are two types or classes assigned to sound level meters: type 1 / class 1 or type 2 / class 2. For assessing noise in basic industrial, commercial, educational, recreational or residential applications, a type 2 / class 2 sound level meter usually will suffice. For precision-grade assessments often made in a laboratory, a type 1 / class 1 sound level meter primarily is used. PCE sound level meter products are lightweight, easy-to-use and manufactured in accordance with the highest industrial standards.

  • OEM Gas Analyzers

    Advanced Energy

    Reduce gas measurement costs with modules that measure multiple gases and eliminate field calibration. Our Andros OEM gas modules lead the way in non-dispersive infrared (NDIR) gas analysis for automotive emissions and patient monitoring.

  • For Overhead Distribution Line Current Tester With Power Flow Direction Record

    MHR-600 - MULTI MEASURING INSTRUMENTS Co., Ltd.

    ・Measuring and recording the average current values & power flow directions in the setting interval.・Easy to use, as an indirect hot-line work tool.・Memorized data can be outputted to USB memoryafter measurement.・For 6.6KV circuit, protection level IP64.

  • Clamp Meter 400A AC

    CZ20067 - Aegis Pty. Ltd.

    The CZ20067 is a an entry level clamp meter for basic electrical testing. The essential measurements of voltage, current, and resistance are included along with diode and continuity testing. The CZ20066 is made rugged to withstand the everyday operation required in the electrical industry.

  • Current, Voltage, Resistance

    Mensor Corp.

    Solutions for the testing and calibration of current, voltage and resistance are used in industry (laboratories, production, workshops), in calibration service companies and in quality assurance. These instruments are portable and mobile and are particularly notable for their low measurement uncertainty and high scope of operation.

Get Help