Filter Results By:

Products

Applications

Manufacturers

Measurement

an acertained value.

See Also: Metrology, Instrumentation, Sensors, Meters, Stability


Showing results: 8431 - 8445 of 10455 items found.

  • Handheld LCR Meter (100Hz to 100kHz)

    ST2822 - Saluki Technology Inc.

    ST2822 series handheld LCR meter is a portable handheld measuring instrument used to measure the parameters of inductance, capacitance, resistance and other components. Small in size, powered by 8.4V rechargeable battery (ST2822A is 9V non-rechargeable battery) or external power adapter, it can be used not only in desktop applications, but also in mobile measurement and handheld measurement.ST2822 series apply the ultra-low power consumption design and high density SMD assembly techniques and can simultaneously display primary and secondary parameters on a LCD display with backlight. The dual-color shell is gorgeously once shaped; and functions are easy to operate. The test frequency is up to 100 kHz, the readings of primary parameter 40,000 counts and the resolution of dissipation factor 0.0001. Accurate and convenient measurements of passive-components can be achieved in different occasions for a long time.

  • Network Analyzer

    DPNA-6G AXIe - Holding Informtest

    The AXI DPNA-6G module is the world's first network analyzer in the form factor of the AXIe-1 module, as well as the first Russian device that meets the AXIe-1 standard. In the mode of the network parameters meter, the AXI DPNA-6G module measures the vector values ​​of the network parameters on two ports: transmission coefficients (S12, S21) and reflection (S11, S22). At the same time, all necessary types of calibrations are supported: one- and two-port short-circuit, XX, matched load, transmission normalization. The software supports the import of third party calibration standard parameters. In the measuring receiver mode, the module provides:*generation of a harmonic signal (frequency synthesizer);*spectrum analyzer and power level in a given band;*measuring the frequency of a known signal;*measurement of analog modulation parameters;*phase noise measurement.

  • Light and Energy Meter

    Model 659 - OAI

    UV Light and Energy Meter for use with all wafer steppers. For over 45 years, OAI is a world leader in UV Light and Energy Measurement Instrumentation used for reliable accurate calibrated control of the photolithography processes in the Semiconductor, MEMS, Wafer Packaging and Wafer Bumping Industries. The New Model 659 is an advanced UV exposure analyzer specifically designed for use with all wafer steppers including high intensity wafer steppers. This meter averages up to 400 exposure readings, has Ethernet and USB interface for downloading recorded measurements, and has intensity range of up to 7,500mW/cm2. Probes are available in wavelength of 365nm, 400nm, 420nm & 436nm. OAI has a complete certified calibration lab to maintain the performance, quality and reliability of our meters. The Model 659 meter is traceable to NIST standards.

  • Portable Electricity Meter Testers

    EE-120A-3S + EE-500V-3 - EMSYST Ltd

    The Phantom Load is able to generate three-phase voltages and currents with unprecedented stability and measurement accuracy. The amplitude and phase-shift of each current and voltage is individually adjustable. All types of electricity meters – mechanical or electronic, for active, reactive or apparent energy, single-phase or three-phase – can be tested with the Energy Standard. The following meter tests can be carried out with the EE Test System: Error Test, Register Test, No Load Test and Starting Current Test. Full analysis of the customer load can also be performed, if current clamps have been ordered. All test results ( maximum 3 Test Plans, 5 Manual Measurements and Customer Load Analysis) can be saved in one file. 100 saved files can be viewed on the LCD display or transferred to a PC via USB port.

  • Air Velocity Meters

    PCE Instruments

    PCE Instruments (PCE) offers a variety of air velocity meter products to meet the air flow and wind speed measurement needs of professionals in industries such as heating, ventilation and air conditioning (HVAC), construction, marine and wind power and energy, including hot-wire air velocity meters, thermo-air velocity meters, pitot tube air velocity meters, cup air velocity meters, rotating vane air velocity meters and impeller air velocity meters with capture hoods. Plus, hobbyists such as boating, sailing and water sports enthusiasts utilize PCE's accurate and affordable digital handheld air velocity meter and portable mini air velocity meter product offerings to evaluate outdoor wind conditions. For meteorological measurements, please see PCE's weather station products.

  • MPO Power Meter, MPO Light Source

    JW3224. JW3124 - Shanghai Joinwit optoelectronic Tech,co.,Ltd

    JW3224MPO Optical Power Meter and JW3124MPO Optical Light Source is special for testing MPO fiber. At recent years, as the rapid development of data centre and cloud computing, also with rapid growth of multi fibers” (MPO) requirement. However, on the site of measurement process, traditional single channel Optical power meter with complex measurement and low credibility. Based on this, JW3224&JW3124 MPO products arises at this monment. The product can test the insertion loss of MPO fibers and polarity with only one key, And the integration of a variety of data storage, threshold analysis, data export and other applications,Compared with the traditional instrument, the test efficiency of JW3224 & JW3124 is more than 10 times,it is the best choice for field application of MPO room test、calibration of production line、Determination of polarity.

  • VLF Diagnostics System

    PHG 80 TD - BAUR Prüf- und Messtechnik GmbH

    Cable testing and diagnostics with the BAUR PHG 80 TD. The combination of the PHG 80 programmable test generator with the BAUR dissipation factor measurement system produces the cable testing and diagnostics system PHG TD. It is operated via PC control. Dissipation factor measurement and diagnostic testing sequences can be programmed in the menu, after which the dissipation factor measured values are automatically determined in various voltage steps and a final evaluation is conducted.* Biggest dynamic range of tan delta measured values from 1 to 10-4 with a cable capacitance >10 nF to 20 uF* High resolution +/- 1x10-5 applicable even in new PE/XLPE cables* Insensitive against interferences due to complete mains separation* Lowest time required for assessing a medium-voltage cable (3-phase approx. 1 hour)

  • VLF Diagnostics System

    PHG 70 TD - BAUR Prüf- und Messtechnik GmbH

    Cable testing and diagnostics with the BAUR PHG 70 TD. The combination of the PHG 70 programmable test generator with the BAUR dissipation factor measurement system produces the cable testing and diagnostics system PHG TD. It is operated via PC control. Dissipation factor measurement and diagnostic testing sequences can be programmed in the menu, after which the dissipation factor measured values are automatically determined in various voltage steps and a final evaluation is conducted.* Biggest dynamic range of tan delta measured values from 1 to 10-4 with a cable capacitance >10 nF to 20 uF* High resolution +/- 1x10-5 applicable even in new PE/XLPE cables* Insensitive against interferences due to complete mains separation* Lowest time required for assessing a medium-voltage cable (3-phase approx. 1 hour)

  • Resistivity Meter

    Model 2180 - Magnetic Instrumentation Inc.

    The unit is compact and lightweight. The basic system is 7″ wide by 2.5″ high and 12″ long. When measurements are needed below approximately 100 micro-ohm-centimeters, the basic system is piggybacked onto a second enclosure that houses a power amplifier with a current gain of ten. The combined unit measures 7″ wide by 5″ high and 12″ long. The combined unit weighs 11.5 pounds. Two short cables interconnect the two enclosures for powering the power amplifier and routing the signals to the fixture or four point probe. The front panel of the basic system includes a 32-character backlit LCD display and a set of function keys. An easy-to-use menu will allow access to user defined parameters such as sample thickness, sample volume, and calibration constants; upper and lower alarm limits, relative measurements, and several others.

  • Dual Vapor Gravimetric Sorption Analyzer

    DVS Resolution - Surface Measurement Systems

    DVS Resolution’s key feature is the combined ability to precisely control and measure temperature and relative humidity while recording the highest resolution changes in mass. DVS Resolution uses a dry carrier gas typically nitrogen or compressed air for its operation. Digital mass flow controllers regulate flows of dry and saturated gases. Relative humidity is generated by precisely mixing dry and saturated gas flows in desired flow ratios which produce expected relative humidity. In a typical experiment a known concentration of water vapor is delivered over a sample placed inside the sample pan connected to the Surface Measurement Systems Ultrabalance™ measuring realtime mass changes caused by sorption or desorption of water molecules. Prior to sorption measurements, the sample can be in-situ preheated/dried at temperatures of up to 300oC.

  • Digital Power Meter, 30A

    66205 - Chroma Systems Solutions, Inc.

    Voltage Ranges:15/30/60/150/300/600 Vrms1200Vrms (optional)Current Ranges : 0.005/0.02/0.05/0.2/0.3/0.5/2/5/20/30 ArmsFrequency Range : DC, 15Hz~10kHzEmbedded high speed DSP, 16 bitsAnalog/Digital converters withmax samipling rate up to 250kHzCapable of meeting the IEC 61000-4-7harmonics measurement requirementsSmart Range function provides seamlesspower integration measurement underauto range modeSupports external shunt and CT forhigher current applications5 mA minimum current range &0.1mW power resolutionMeets ENERGY STAR /EN 50564/IEC 62301/ErP requirementsUser-define criteria providesautomatic PASS/FAIL indicationsTHD and user-specify order distortionmeasurementInrush current and energy measurementsVoltage/ Current harmonics measurementsup to 100 ordersUSB (Host) interface provides data loggingfunctionalitySupport GPIB, USB, RS232, LAN (option)interface

  • Professional Home Inspection Kit - Aids in Identification of Moisture, HVAC, Electrical and Hot Water System Issues

    Extech MO280-KH2 - Extech Instruments Corporation

    Professional Home Inspection Kit aids in the identification of moisture, HVAC, electrical and hot water system issues. Kit includes a Pinless Moisture Meter for non-invasive moisture detection of wood/building materials with a measurement depth of 0.75" (22mm) below the surface, Infrared Thermometer for non-contact surface measurement from -4 to 752°F (-20 to 400°C) with a built-in laser to improve aim and identify the target area. It has adjustable emissivity with 12:1 distance to target ratio and is ideal for testing HVAC supply and return applications and a Waterproof Stem Thermometer measuring from -40 to 392°F (-40 to 200°C) with a 2.75" (70mm) stainless steel stem. Kit is supplied in an attractive storage case that provides protection and organization for the testers whenever they are needed.

  • Vibration Analysis Software For Squeak & Rattle Testing

    MB BSR Suite - MB Dynamics Inc.

    MB BSR SUITE is the complete solution for all measurement tasks in the field of NVH, Squeak & Rattle and Sound Quality testing. Comprehensive analysis and assessment capabilities also enable the use of the BSR Suite for analysis and evaluation of functional and operating noise, vibrational effects on humans as well as the acoustic and haptic feedback of controls and actuators. Predefined test configurations for typical tasks such as multi-channel road load data acquisition, drive-file generation and objective Squeak & Rattle and Sound Quality testing allow for fast and simple operation. Signal statistics and user defined thresholds or reference-curves can be used for objective evaluation of different acoustic or haptic quality criteria. In addition the development and integration of application- or customer-specific analyses and evaluation methods is also possible at any time. Contact MB to find a solution for your measurement task!

  • 24-Bit High-Resolution Dynamic Signal Acquisition and Generation Module

    PCI-9527L - ADLINK Technology Inc.

    The PCI-9527L is a high-performance, 2-CH analog input and 2-CH analog output dynamic signal acquisition board. This board is specifically designed for audio testing, acoustic measurement, and vibration analysis applications.The ADLINK PCI-9527L features two 24-bit simultaneous sampling analog input channels. The 24-bit sigma-delta ADC provides a sampling rate up to 216 KS/s at high resolutions, making it ideal for higher bandwidth dynamic signal measurements. The sampling rate can be adjusted by setting the onboard DDS clock source to an appropriate frequency. All channels are sampled simultaneously and accept an input range from ±40 V to ±0.316 V. The PCI-9527L analog input supports software selectable AC or DC coupling and 4 mA bias current for integrated electronic piezoelectric (IEPE) sensors.

  • TDR Cable Analyzer

    CT100B - MOHR Test and Measurement llc

    The CT100B is special for two reasons: (1) It is the industry''s only high-resolution portable TDR providing step TDR impedance waveforms with resolution sufficient to show connector detail (~1 cm), and (2) it is the industry''s first portable TDR capable of making frequency domain S-parameter measurements including return loss (S11) and cable loss / insertion loss (S21). "High resolution TDR is extremely useful for detecting and localizing cable faults and characterizing cable and connector performance, but historically, portable TDRs have been unable to display OSL-calibrated S-parameter measurements," said Brandt Mohr, MOHR chief technologist. "The CT100B includes that capability, making it a very versatile instrument. If you can only carry one cable tester out into the field with you, it should be the CT100B."

Get Help