  • Digital Power Meter (High Accuracy Model)

    LS2050 - Lisun Electronics Inc.

    LS2050 digital power meter is a new generation intelligent product which adopts digital sampling technology to analysis of the waveform. It has the following features: • Three windows digital display which reduces reading error, intuitive and convenient • Adopts high speed MCU and high precision A/D to control and measurement • All measured data as virtual value, also suit to signal waveform distortion • Fast test • Equipped with RS232 communicate function, can use upper computer software to carry on remote operation, control and read corresponding data, the test data and waveform could be displayed in the PC, Chinese and English operation interface, high intelligent instrument • This instrument provides two kinds of method to calculate total harmonic distortion (THD), IEC and CSA.

  • 0.1Hz-2MHz AM/FM Functional Generator

    MFG-8202 - MCH Instruments Co.,Ltd.

    Features:• Low distortion, high stability• Linear and logarithmic sweep function• Sweep time and width adjustable• External Voltage Control Frequency (VCF)• Internal & external modulation (AM/FM) with modulation control• Output signal compatible with TTL/CMOS• Seven types of waveforms such as sine, square, triangle and ramp• 5W power output (ONLY for model no with “B”)• DC offset and 40bD attenuation can be applied to main output signal• Built-in frequency meter 0.1Hz~30MHz

  • 0.1Hz-5MHz AM/FM Functional Generator

    MFG-8205 - MCH Instruments Co.,Ltd.

    Features:• Low distortion, high stability• Linear and logarithmic sweep function• Sweep time and width adjustable• External Voltage Control Frequency (VCF)• Internal & external modulation (AM/FM) with modulation control• Output signal compatible with TTL/CMOS• Seven types of waveforms such as sine, square, triangle and ramp• 5W power output (ONLY for model no with “B”)• DC offset and 40bD attenuation can be applied to main output signal• Built-in frequency meter 0.1Hz~30MHz

  • Signa; Generator

    MAG-203AD - MCH Instruments Co.,Ltd.

    Features:*Signal frequency:0 .1Hz-2Mhz, continuously variable*Wave form: square,sine*Output attenuator:0dB, 20dB, 40dB,60dB*Output level: 20Vp-p in open circuit, not less than 10Vp-p with 50Ω load*Rising and falling edge of square not more than 35ns*Sine distortion less than 1%,amplitude -frequency characterstic:±0.3dB within 100khz, ±1dB above 1Mhz*Frequency meter: 10Hz-30Mhz*Power supply : AC 220V

  • Digital Signal Generator

    MCH Instruments Co.,Ltd.

    Digital Signal Generator*signal frequency:0.1Hz~2MHz, continuously variableave from: square, sine*output attenuator: 0dB,, 20dB, 40dB, 60dB*output level: 20Vp-p in open circuit, not less than 10Vp-p with 50Ω load*rising and falling edge of square not more than 35ns,*sine distortion less than 1%, amplitude –frequency characteristic : ±0.5dB within 100KHz, ±1dB above 1MHz*frequency meter: 10Hz~30MHz*power supply : AC 220V(110V optional)

  • Wideband Power Amplifiers

    Krohn-Hite Corporation

    Krohn-Hite Wideband Power Amplifiers are designed to meet today's industrial needs where wideband, precision performance is required. Applications include: meter calibration, piezo transducer driving, bridging applications requiring high input and low output impedance, low distortion ac power source, ion beam deflection, vacuum tube driver, ink jet testing and design and many more.

  • Automated Test Interface

    ATI-100 - Matrix Test Equipment Incorporated

    Now, with our ?New? Model ATI-100 you can turn your existing Matrix Signal Generator and Switchable Filter Bank into a full-blown DTS (Distortion Test System). Plug and play is the word, just plug in your Multiple Frequency Signal Generator, Switchable Filter Bank, Spectrum Analyzer, Oscilloscope, Power Meter, Frequency Counter, etc. to allow the following automatic testing with a single insertion of DUT (device under test

  • TDR Structural Health Monitoring

    Material Sensing & Instrumentation

    MSI Time-Domain-Reflectometry (TDR) Structural-Health Monitoring probes the structural health of a composite part by propagating a fast electrical pulse along a distributed linear sensor which has been fabricated directly in the laminate. The sensor is formed from the native graphite fibers already used in composite manufacture, and constitutes zero defect. Fibers are patterned into a microwave waveguide geometry, or transmission line, and interrogated by a rapid pulse as shown below. Structural faults along the line cause distortions in waveguide geometry, producing reflected pulses similar to radar. Cracking, delamination, disbonds, moisture penetration, marcelling, and strain are all detected by propagation delay, for sensor lengths up to several meters.

  • PWM Type AC Power Supply

    LSP-5KVA - Lisun Electronics Inc.

    • Circuit Type: (IGBT) MPWM Pulse Duration Modulation • Input: 1 Phase 220V±10%, 50Hz/60Hz±5% • Output Voltage: HIGH/LOW Adjustable 1)1 Phase Voltage Range: (HIGH)0~300V, (LOW)0~150V 2) Nominal Voltage: +10%~+25%, -10%~-30% • Output Frequency: 50Hz, 60Hz, adjustable between 45 and 70 Hz, 400Hz • Load Voltage Stabilization Rate: ≦0.5% • Frequency Stabilization Rate: 0. 1% (Fix Point 50Hz, 60Hz and 400Hz) • Wave Distortion Rate: ≦2% (Resistor Load); Efficiency: ≧85% • Output Instruments: Frequency Indicator, 4-digits RMS digital frequency indicator, resolution is  0.1Hz Voltage Meter, 4-digits RMS digital voltage meter, resolution 0.1V Ampere Meter, 4-digist RMS digital ampere meter, resolution 1Ma Power Indicator, 4-digits RMS digital power indicator, resolution 1W Power Factor Meter  Resolution 0.001 • Protective Devices: Over load, short circuit, over voltage, over current, over temperature protective and alarm devices • Operating Environment: Temperature 0~40℃ Relative Humidity 0~90%