Showing results: 1 - 15 of 85 items found.
-
TRM 1000 -
AJIT Electronics Co.
AJIT Transformer Ratio Meters are the most modern turn's radio meters widely used to test the turn's ratio of high voltage windings, to low voltage windings, of Transformer. These meters are accurate, compact & light in weight.
-
Model TRM200 -
Gopal Electronics
Turns Ratio Meter Model TRM200 is widely used in transformer industry in manufacturing and repairing service. It directly display the ratio of LT turns & HT turns. It is capable to measure turns ratio till 1:1200. Turns ratio meter is designed to be a rugged and reliable. It is equipped with stable 250mA source. The design is based upon in-house invented & patented technology. TRM200 has also option for 1amp current source on demand.
-
Eltel Industries
The CVT Range Extender is an accessory for the ELTEL TRM-100,TRM-150,TRM-200 and ATRM-200 Transformer Ratio Meters and designed to test high ratios of CVTs used on High Voltage Systems. Provides a 1:40 range extension.
-
Shenzhen Golight Technology Co.,Ltd
The extinction ratio meter can achieve accurate measurement of up to 40dB PER dynamic range. The instrument is precisely controlled by micro-machines, which can quickly and accurately measure the extinction ratio, polarization angle and optical power of the polarization-maintaining device.
-
Thorlabs, Inc.
The ERM100 is an extinction ratio meter based on the rotating polarizer technique. This benchtop device offers a fast and simple way to measure the ER of Polarization Maintaining (PM) fibers. It is an easy-to-use device that may be utilized in many applications where the alignment of PM fibers is required.
-
ERM-202 -
General Photonics Corp.
The ERM-202 is a single or dual channel polarization extinction ratio (PER) meter. When used with a broadband source, it directly measures PER. Single and dual channel models are available. The single channel instrument can be upgrades to two channels version at a later date. By combining low noise circuitry with a high resolution stepper, the ERM series achieves a PER dynamic range of 50 dB.
-
Three Phase Transformer Ratio Meter Standard Series -
Amperis sl
TRT is based on state-of-the-art technology, using the most advanced technique available today. The test equipment can be used to test both single-phase and three-phase transformers, both with and without tap changer in accordance with the requirements of IEC 60076-1.
-
TRM-200 -
Eltel Industries
Three phase lead switching network • Excitation current meter Accessories: Range Extender 1:5.
-
Amperis sl
The TRT is based on state-of-the-art technology and uses the most advanced technique available today. The test equipment can be used to test both single-phase and three-phase transformers, both with and without tap changer in accordance with the requirements of IEC 60076-1.
-
Handheld Turns Ratio & Winding Resistance Tester TWR-H -
Amperis sl
TWR-H is a handheld, battery operated, fully automatic test set specially designed for turns ratio, phase shift, excitation current and winding resistance measurements of transformers. It can also perform demagnetization of these transformers. Transformer turns ratio is determined by applying AC voltage across high voltage winding, accurately measuring AC voltage across the corresponding unloaded transformer winding, and then displaying the ratio of these voltages. User can enter a transformer’s nameplate voltages, so that turns ratio deviation can be calculated. This feature eliminates any error otherwise caused by an operator’s manual calculation. TWR-H compares measured turns ratio with the nameplate ratio and prints out the % of error for each test. Transformer winding resistance is determined by injecting DC current through a winding, accurately measuring DC voltage across the winding, and then calculating resistance as the ratio of voltage and current. The device generates true DC ripple-free currents. Both the injection of the current and the discharge of energy from transformer magnetic circuit are automatically regulated.
-
-
NEO TELE-TRONIX PVT. LTD
We are considered as one of the leading manufacturers and exporters of Transformer Turns Ratio Meter With/ Without Phase. The equipment is widely used in power generation and engineering industry for testing of transformers. We engineer and develop this testing equipment in accordance with industry standards using best grade components and raw materials. This Transformer Turns Ratio Meter With/ Without Phase can be also optimized according to client's specific requirement. We offer this testing equipment at competitive price.
-
TTRM 302 -
Scope T&M Pvt, Ltd.
SCOPE introduces state of the art precision three phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. Along with turns ratio, this light weight and reliable instrument measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single as well as three phase transformers in charged switchyard condition. The instrument has facility to automatically detect vector group of all majority configurations available. The differant AC voltage selection offers high accuracy in measurement.
-
TTRM 301 -
Scope T&M Pvt, Ltd.
SCOPE introduces state of the art precision three phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. Along with turns ratio, this light weight and reliable instrument measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single as well as three phase transformers in charged switchyard condition. The instrument has facility to automatically detect vector group of all majority configurations available. The differant AC voltage selection offers high accuracy in measurement.
-
TTRM 101 -
Scope T&M Pvt, Ltd.
SCOPE introduces state of the art precision single phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. TTRM 101 measures only turns ratio where as TTRM 102 along with turns ratio, measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single phase transformer in charged switchyard condition. The range of AC voltage selection offers high accuracy in measurement.Both the instrument have in-built TFT display with touch screen and thermal printer. The user friendly, simple instrument makes the testing more easy. With the touch keypad it is possible to enter required DUT information.The ratio results are displayed with % error. Internal non-volatile memory gives the provision of storing test results.Further data can be downloaded to PC or copied to memory stick through USB port provided.