Filter Results By:

Products

Applications

Manufacturers

Ratio Meters

measure power's peak-to-average ratio level.


Showing results: 91 - 94 of 94 items found.

  • Professional Home Inspection Kit - Aids in Identification of Moisture, HVAC, Electrical and Hot Water System Issues

    Extech MO280-KH2 - Extech Instruments Corporation

    Professional Home Inspection Kit aids in the identification of moisture, HVAC, electrical and hot water system issues. Kit includes a Pinless Moisture Meter for non-invasive moisture detection of wood/building materials with a measurement depth of 0.75" (22mm) below the surface, Infrared Thermometer for non-contact surface measurement from -4 to 752°F (-20 to 400°C) with a built-in laser to improve aim and identify the target area. It has adjustable emissivity with 12:1 distance to target ratio and is ideal for testing HVAC supply and return applications and a Waterproof Stem Thermometer measuring from -40 to 392°F (-40 to 200°C) with a 2.75" (70mm) stainless steel stem. Kit is supplied in an attractive storage case that provides protection and organization for the testers whenever they are needed.

  • Function Generators

    Shanghai MCP Corp

    Respective dual channels function/arbitrary waveform generator. Sine wave output up to 160MHz, full-band resolution of 1μHz. Pulse waveform up to 50MHz (or 40MHz), adjustable time of rising, falling and duty ratio. Sampling rate of 500MSa/s and vertical resolution of 16bit. 6-bit high-precision frequency meter compatible with TTL level signal. Arbitrary wave storage of 8~32M points, 7GB non-volatile waveform storage. Multi modulation function::AM,FM,PM, ASK,FSK,PSK, BPSK, QPSK,OSK,PWM, QAM, SUM . 16bit digital arbitrary wave (TTL level) DARB. 16th Harmonic Generation Function. Protocol output: I2C, SPI, UART (TTL level). 8 Inch high-resolution TFT color LCD,WVGA(800×480). Standard interface: USB Host, USB Device, LAN, 10MHz clock source input/output. Frequency sweep and burst output. Easy-to-use multi-functional knob and numeric keypad

  • ​Gas Filter Correlation Carbon Monoxide Analyzer​

    Model T300 - Teledyne Monitor Labs

    The Model T300 measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 14 meters. The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing extreme sensitivity. All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information, is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software​.​​

  • Relay Test Set

    RNT-5A - Neutronics Manufacturing Co.

    This is a portable testing kit in one unit, suitable for testing protective relay, over current relay, earth fault relay, protective device, circuit breaker, tripping coils etc.The set is designed for both laboratory and field use. TECHNICAL FEATURES: INPUT : 230 Volts, single phase, 50Hz. AC. OUTPUTS : : 1) Current Output: a) 0- 1Amp. At 6/60Volts. (Continuous duty). b) 0- 5 Amps. At 6/60 Volts. (Continuous duty). c) 0- 10 Amps. At 6/60 Volts. (Continuous duty). d) 0- 20 Amps. At 6 Volts. (for30 min. duty). e) 0- 50 Amps. At 6Volts. (For 10 min. duty). f) 0-100 Amps. At 6 volts. (For10 min. duty). g) 0-200 Amps at 6Volts. (For 30 sec. duty). Current output is continuously variable and the output is taken out through a multi range C.T. The secondary is connected to an ammeter scaled in 0 to 100%. Output current range 1Amp. To 20Amps. Are selected by current range selector switch with common output terminals and for other three ranges three brass terminals are provided of proper ratting. 2) AC Voltage Output: Continuously variable 0 -230V AC. Capacity- 240VA (Max). OR DC Voltage Output: Continuously Variable 0-240V DC. Capacity-240VA.(max). One change over switch should be provided for selection of Volt. Meter for AC or DC voltage output & either AC or Dc voltage should be available at a time. 3) Time Measurement: 0-9.999Secs. & 0-99.99Secs. in two ranges. Accuracy: 1% CURRENT CIRCUIT: Loading transformer: Double winding loading transformer of suitable burden to provided corresponding current output specified before. One change over switch in current ckt. To be provided for voltage selection i.e. selection of 10volt. Or 50volt. Measuring CT: Multi ratio wound primary current transformer Ratio : 1-5-10-20-50-100-200A/5A. Variable auto transformer: For smooth variation of current output at various ranges selected. Tripping circuit: The current output will be cutoff incase of any overload for the range 200A or even if the relay under test actuated.

Get Help